{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,13]],"date-time":"2023-10-13T04:42:55Z","timestamp":1697172175283},"reference-count":18,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2004,3,29]],"date-time":"2004-03-29T00:00:00Z","timestamp":1080518400000},"content-version":"vor","delay-in-days":28,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Seminars in Dialysis"],"published-print":{"date-parts":[[2004,3]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:p>Bowel perforation is a well\u2010recognized complication of peritoneal dialysis catheter insertion and is associated with increased morbidity and cost of medical care. In this article we describe our 2\u2010year experience (August 2001\u2013October 2003) with a modified peritoneoscopic technique of peritoneal dialysis catheter insertion to minimize the incidence of bowel perforation. Seventy patients underwent 82 consecutive peritoneal dialysis catheter insertions using the innovative technique. The modified technique is very similar to the traditional peritoneoscopic procedure except for the following differences. To gain access to the peritoneal cavity, a Veress insufflation needle (Ethicon Endo\u2010Surgery Inc., Cincinnati, OH) is utilized instead of the trocar. In contrast to the sharp tip of the trocar, the Veress needle has a blunt, self\u2010retracting end. In addition, the Veress needle is only 14 gauge as opposed to the 2.2 mm diameter of the trocar. Upon introduction of the Veress needle into the abdominal cavity, two \u201cpops\u201d are discerned similar to the trocar. After introduction, 400\u2013500 cc of air are infused and the needle is removed. The infusion of air creates a space between the peritoneal surface of the anterior abdominal wall and the bowel loops. At this point, the cannula with trocar is inserted into the space created. The rest of the steps of the procedure are the same as the traditional peritoneoscopic technique. Utilizing the innovative technique, all 82 catheter insertions were performed successfully without a single bowel perforation. No other complications except for catheter migration (<jats:italic>n<\/jats:italic>\u00a0=\u00a02) were noted. The extra cost of the needle ($35) should be viewed in the context of the costs associated with management of a bowel perforation. Large\u2010scale studies are needed to confirm the superiority of this innovative technique over the traditional peritoneoscopic insertion found in our case series. In the interim, however, the increased morbidity and cost associated with bowel perforation calls for logical measures to be taken to avoid this dreaded complication.<\/jats:p>","DOI":"10.1111\/j.0894-0959.2004.17221.x","type":"journal-article","created":{"date-parts":[[2004,3,29]],"date-time":"2004-03-29T09:44:34Z","timestamp":1080553474000},"page":"171-173","source":"Crossref","is-referenced-by-count":25,"title":["American Society of Diagnostic and Interventional Nephrology: Modification of the Peritoneoscopic Technique of Peritoneal Dialysis Catheter Insertion: Experience of an Interventional Nephrology Program"],"prefix":"10.1111","volume":"17","author":[{"given":"Arif","family":"Asif","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan","family":"Tawakol","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tasnim","family":"Khan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cristovao F.","family":"Vieira","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patricia","family":"Byers","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Florin","family":"Gadalean","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rene","family":"Hogan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Donna","family":"Merrill","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Roth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2004,3,29]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0272-6386(99)70266-0"},{"key":"e_1_2_7_3_2","doi-asserted-by":"crossref","unstructured":"AsifA ByersP VieiraCF MerrillD GadaleanF BourgoignieJJ LeclercqB RothD GadallahMF:Peritoneoscopic placement of peritoneal dialysis catheter and bowel perforation: experience of an interventional nephrology program.Am J Kidney Dis42:1270\u20131274 2003","DOI":"10.1053\/j.ajkd.2003.08.029"},{"key":"e_1_2_7_4_2","first-page":"M154","article-title":"Prospective comparison of peritoneoscopic and surgical implantation of CAPD catheters","volume":"37","author":"Pastan S","year":"1991","journal-title":"Trans Am Soc Artif Organs"},{"issue":"1","key":"e_1_2_7_5_2","doi-asserted-by":"crossref","first-page":"S330","DOI":"10.1177\/089686089601601S63","article-title":"Peritoneoscopic placement of swan neck peritoneal dialysis catheters","volume":"16","author":"Copley JB","year":"1996","journal-title":"Perit Dial Int"},{"key":"e_1_2_7_6_2","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1177\/089686088300300104","article-title":"Peritoneoscopic placement of the Tenckhoff catheter: further clinical experience","volume":"3","author":"Ash SR","year":"1983","journal-title":"Perit Dial Bull"},{"key":"e_1_2_7_7_2","first-page":"33","article-title":"Who should place peritoneal catheters? A nephrologist's view","volume":"7","author":"Ash SR","year":"1993","journal-title":"Nephrol News Issues"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(68)90066-4"},{"key":"e_1_2_7_9_2","first-page":"219","article-title":"The permanent Tenckhoff catheter for chronic peritoneal dialysis","volume":"113","author":"Devine H","year":"1975","journal-title":"Can Med Assoc J"},{"key":"e_1_2_7_10_2","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1681\/ASN.V31103","article-title":"Modification of the percutaneous approach to peritoneal dialysis catheter placement under peritoneoscopic visualization: clinical results in 78 patients","volume":"3","author":"Nahman NS","year":"1992","journal-title":"J Am Soc Nephrol"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1053\/snep.2002.31710"},{"key":"e_1_2_7_12_2","first-page":"195","article-title":"Conservative treatment of recognized laparoscopic colonic injury","volume":"2","author":"Berry MA","year":"1998","journal-title":"Journal of the Society of Laparoendoscopic Surgeons"},{"key":"e_1_2_7_13_2","first-page":"74","article-title":"Laparoscopic bowel injury","volume":"2","author":"Reich H","year":"1992","journal-title":"Surg Laparosc Endosc"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0016-5107(89)72688-2"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.1007\/s004649900461"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02049986"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02055129"},{"key":"e_1_2_7_18_2","first-page":"47","article-title":"The role of peritoneal dialysis catheter configuration in preventing catheter tip migration","volume":"16","author":"Gadallah MF","year":"2000","journal-title":"Adv Perit Dial"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0272-6386(00)70340-4"}],"container-title":["Seminars in Dialysis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.0894-0959.2004.17221.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.0894-0959.2004.17221.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,12]],"date-time":"2023-10-12T20:44:52Z","timestamp":1697143492000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.0894-0959.2004.17221.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,3]]},"references-count":18,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2004,3]]}},"alternative-id":["10.1111\/j.0894-0959.2004.17221.x"],"URL":"https:\/\/doi.org\/10.1111\/j.0894-0959.2004.17221.x","archive":["Portico"],"relation":{},"ISSN":["0894-0959","1525-139X"],"issn-type":[{"value":"0894-0959","type":"print"},{"value":"1525-139X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,3]]}}}