{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T05:18:53Z","timestamp":1767676733708,"version":"build-2065373602"},"reference-count":44,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2007,2,22]],"date-time":"2007-02-22T00:00:00Z","timestamp":1172102400000},"content-version":"vor","delay-in-days":4435,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Anaesthesia"],"published-print":{"date-parts":[[1995,1]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:p>A new prototype laryngeal mask airway is described which incorporates a second mask to isolate the upper oesophagus and a second dorsal cuff to increase the seal against the glottis. We have made a within\u2010patient comparison of seal pressures between the prototype and standard laryngeal mask airway in 20 patients, and determined if the prototype facilitates functional isolation of the glottis and upper oesophagus. Leak pressure was found to be significantly higher for the prototype and equalled or exceeded 5.0kPa in all patients (p &lt; 0.001). The prototype laryngeal mask airway provided functional isolation in all patients as judged by leak and placement of a gastric tube via the oesophageal mask. Ease of insertion and incidence of pharyngeal morbidity appeared similar to the standard laryngeal mask, but were not formally tested. The prototype laryngeal mask airway exhibits potentially useful new features which justify further evaluation and development.<\/jats:p>","DOI":"10.1111\/j.1365-2044.1995.tb04513.x","type":"journal-article","created":{"date-parts":[[2007,2,23]],"date-time":"2007-02-23T07:26:14Z","timestamp":1172215574000},"page":"42-48","source":"Crossref","is-referenced-by-count":36,"title":["A new laryngeal mask prototype"],"prefix":"10.1111","volume":"50","author":[{"given":"A. I. J.","family":"BRAIN","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"VERGHESE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"STRUBE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"BRIMACOMBE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2007,2,22]]},"reference":[{"key":"e_1_2_1_2_2","first-page":"5","article-title":"The development of the laryngeal mask\u2014a brief history of the invention, early clinical studies and experimental work from which the laryngeal mask evolved","volume":"4","author":"Brain AIJ.","year":"1991","journal-title":"European Journal of Anaesthesiology"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/0952-8180(92)90077-E"},{"key":"e_1_2_1_4_2","first-page":"19","article-title":"The laryngeal mask\u2014an overview","volume":"4","author":"Leach AB","year":"1991","journal-title":"European Journal of Anaesthesiology"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199307000-00021"},{"key":"e_1_2_1_6_2","first-page":"183","volume-title":"Anesthesia Review 10","author":"Brimacombe J","year":"1993"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03008663"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199211000-00001"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/70.2.124"},{"volume-title":"The intavent laryngeal mask\u2014instruction manual","year":"1993","author":"Brain AIJ.","key":"e_1_2_1_10_2"},{"volume-title":"Recommendations for standards of monitoring during anaesthesia and recovery","year":"1989","author":"Adams AP","key":"e_1_2_1_11_2"},{"volume-title":"Statistical methods in medical research","year":"1997","author":"Armitage P.","key":"e_1_2_1_12_2"},{"volume-title":"Statistical methods in clinical and preventative medicine","year":"1962","author":"Hill AB.","key":"e_1_2_1_13_2"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/55.8.801"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199403000-00011"},{"journal-title":"Journal of Clinical Anesthesia.","article-title":"The incidence of aspiration associated with the laryngeal mask airway\u2014a meta\u2010analysis of published literature","author":"Brimacombe J","key":"e_1_2_1_16_2"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199301000-00010"},{"key":"e_1_2_1_18_2","first-page":"29","article-title":"Aspiration pneumonitis: fact or fiction","volume":"2","author":"Kallar SK.","year":"1988","journal-title":"Problems in Anesthesia"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/72.4.496"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03008711"},{"key":"e_1_2_1_21_2","doi-asserted-by":"publisher","DOI":"10.1213\/00000539-199377020-00051"},{"key":"e_1_2_1_22_2","first-page":"534","article-title":"Aspiration and the laryngeal mask airway\u2014a survey of Australian intensive care units","volume":"20","author":"Brimacombe J","year":"1992","journal-title":"Anaesthesia and Intensive Care"},{"key":"e_1_2_1_23_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-998898"},{"key":"e_1_2_1_24_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1993.tb07199.x"},{"key":"e_1_2_1_25_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03008676"},{"key":"e_1_2_1_26_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1990.tb14882.x"},{"key":"e_1_2_1_27_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1990.tb14296.x"},{"key":"e_1_2_1_28_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/69.3.314"},{"key":"e_1_2_1_29_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/69.4.346"},{"key":"e_1_2_1_30_2","first-page":"A1053","article-title":"Incidence of gastroesophageal reflux with the laryngeal mask:","volume":"79","author":"Owens T","year":"1993","journal-title":"Anesthesiology"},{"key":"e_1_2_1_31_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/72.4.447"},{"key":"e_1_2_1_32_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/70.3.380-b"},{"key":"e_1_2_1_33_2","first-page":"529","article-title":"Gastric regurgitation during general anaesthesia in the supine position with the laryngeal and face mask airways","volume":"68","author":"El Mikatti N","year":"1992","journal-title":"British Journal of Anaesthesia"},{"key":"e_1_2_1_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/0959-289X(92)90015-V"},{"key":"e_1_2_1_35_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1992.tb03196.x"},{"key":"e_1_2_1_36_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1993.tb06794.x"},{"key":"e_1_2_1_37_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199309000-00024"},{"key":"e_1_2_1_38_2","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1177\/0310057X9302100121","article-title":"Insertion of the laryngeal mask airway\u2014a prospective study of four techniques","volume":"21","author":"Brimacombe J","year":"1993","journal-title":"Anaesthesia and Intensive Care"},{"key":"e_1_2_1_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/0014-4886(68)90080-0"},{"key":"e_1_2_1_40_2","doi-asserted-by":"publisher","DOI":"10.1016\/0034-5687(83)90075-0"},{"key":"e_1_2_1_41_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1992.tb02173.x"},{"key":"e_1_2_1_42_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/70.1.25"},{"key":"e_1_2_1_43_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03009998"},{"key":"e_1_2_1_44_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1989.tb09291.x"},{"key":"e_1_2_1_45_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1990.tb14480.x"}],"container-title":["Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2044.1995.tb04513.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1365-2044.1995.tb04513.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T15:43:02Z","timestamp":1761666182000},"score":1,"resource":{"primary":{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/10.1111\/j.1365-2044.1995.tb04513.x"}},"subtitle":["Preliminary evaluation of seal pressures and glottic isolation"],"short-title":[],"issued":{"date-parts":[[1995,1]]},"references-count":44,"journal-issue":{"issue":"1","published-print":{"date-parts":[[1995,1]]}},"alternative-id":["10.1111\/j.1365-2044.1995.tb04513.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1365-2044.1995.tb04513.x","archive":["Portico"],"relation":{},"ISSN":["0003-2409","1365-2044"],"issn-type":[{"type":"print","value":"0003-2409"},{"type":"electronic","value":"1365-2044"}],"subject":[],"published":{"date-parts":[[1995,1]]}}}