{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T05:19:42Z","timestamp":1776230382942,"version":"3.50.1"},"reference-count":42,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2007,9,7]],"date-time":"2007-09-07T00:00:00Z","timestamp":1189123200000},"content-version":"vor","delay-in-days":3993,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Anaesthesia"],"published-print":{"date-parts":[[1996,10]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:p>\n                    Indwelling, cuffed, tunnelled, central venous (Hickman) catheters are increasingly being used for venous access and the administration of chemotherapy for oncological patients. This paper reviews the technical problems associated with the percutaneous insertion of these catheters and the complications arising from their use. Five hundred and sixty catheters were inserted; 31.3% had complications at insertion, most commonly precipitation of an arrhythmia (13.9%). Arterial puncture occurred in 3.8% and pneumothorax in 1.6%. Catheters remained in place for a median period of 91 days. Forty percent of catheters were removed electively on completion of treatment; 30.2% required removal because of complications, which included sepsis, migration, thrombosis and blockage. Twenty percent of patients died with their catheter in place, 8.5% were still\n                    <jats:italic>in situ<\/jats:italic>\n                    and 1.6% were removed because of patient non compliance. Sepsis remains the commonest, long term complication, with staphylococcus epidermidis being the organism isolated most frequently. There were no catheter\u2010related deaths.\n                  <\/jats:p>","DOI":"10.1111\/j.1365-2044.1996.tb14972.x","type":"journal-article","created":{"date-parts":[[2007,9,7]],"date-time":"2007-09-07T07:11:01Z","timestamp":1189149061000},"page":"981-985","source":"Crossref","is-referenced-by-count":55,"title":["A review of 560 Hickman catheter insertions"],"prefix":"10.1111","volume":"51","author":[{"given":"S.","family":"Ray","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Stacey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Imrie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Filshie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2007,9,7]]},"reference":[{"key":"e_1_2_1_2_2","first-page":"396","article-title":"Percutaneous insertion of Hickman type catheters","volume":"46","author":"Stacey RGW","year":"1991","journal-title":"British Journal of Hospital Medicine"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1177\/0148607187011005502"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-76-3-112-6-423"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005792-198407000-00001"},{"key":"e_1_2_1_6_2","first-page":"673","article-title":"Insertion of Hickman catheters. A comparison of cutdown and percutaneous techniques","volume":"50","author":"Davis SJ","year":"1984","journal-title":"The American Surgeon"},{"key":"e_1_2_1_7_2","first-page":"133","article-title":"Radiological placement of indwelling central venous lines for dialysis. TPN, and chemotherapy","volume":"6","author":"Gray RR.","year":"1991","journal-title":"Journal of Interventional Radiology"},{"key":"e_1_2_1_8_2","first-page":"S122","article-title":"A comparative review of surgically and radiologically placed Hickman Catheters","volume":"17","author":"McBride KB","year":"1994","journal-title":"Cardiorascular and Interventional Radiology"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02096462"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.170.3.2916052"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1177\/0148607187011005505"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(83)90922-4"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1002\/1097-0142(19850315)55:6<1312::AID-CNCR2820550626>3.0.CO;2-9"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01963064"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/0140-6736(93)92815-B"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1001\/archinte.153.15.1791"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9610(85)80142-2"},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1002\/1097-0142(19891015)64:8<1747::AID-CNCR2820640832>3.0.CO;2-F"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1002\/jso.2930390304"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1177\/0148607184008005501"},{"key":"e_1_2_1_21_2","doi-asserted-by":"publisher","DOI":"10.1177\/014860718901300192"},{"key":"e_1_2_1_22_2","doi-asserted-by":"publisher","DOI":"10.1002\/jso.2930260403"},{"key":"e_1_2_1_23_2","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1128\/jcm.21.3.357-360.1985","article-title":"Pathogenesis of catheter sepsis: a prospective study with quantitative and semiquantitative cultures of catheter hub and segments","volume":"21","author":"Linares J","year":"1985","journal-title":"Journal of Clinical Microbiology"},{"key":"e_1_2_1_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(84)91800-2"},{"key":"e_1_2_1_25_2","first-page":"355","article-title":"Catheter sepsis: the clue is the hub","volume":"97","author":"Sitges\u2010Serra A","year":"1985","journal-title":"Surgery"},{"key":"e_1_2_1_26_2","doi-asserted-by":"publisher","DOI":"10.1002\/1097-0142(19871015)60:8<1891::AID-CNCR2820600836>3.0.CO;2-Z"},{"key":"e_1_2_1_27_2","first-page":"39","article-title":"Teicoplanin and prophylaxis of Hickman catheter insertions","volume":"567","author":"Lim SH","year":"1992","journal-title":"European Journal of Surgery-Suppl."},{"key":"e_1_2_1_28_2","doi-asserted-by":"publisher","DOI":"10.1002\/1097-0142(19900901)66:5<900::AID-CNCR2820660515>3.0.CO;2-A"},{"key":"e_1_2_1_29_2","first-page":"57","article-title":"Thrombotic complications of silicone rubber catheters during autologous marrow and peripheral stem cell transplantation: prospective comparison of Hickman and Groshong catheters","volume":"7","author":"Haire WD","year":"1991","journal-title":"Bone Marrow Transplantation"},{"key":"e_1_2_1_30_2","doi-asserted-by":"publisher","DOI":"10.1001\/archinte.149.5.1209"},{"key":"e_1_2_1_31_2","doi-asserted-by":"publisher","DOI":"10.1177\/0148607189013004397"},{"key":"e_1_2_1_32_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.99.1.54"},{"key":"e_1_2_1_33_2","doi-asserted-by":"publisher","DOI":"10.1002\/1097-0142(19921001)70:7<1895::AID-CNCR2820700715>3.0.CO;2-I"},{"key":"e_1_2_1_34_2","doi-asserted-by":"crossref","first-page":"2868","DOI":"10.1001\/jama.1982.03330210050034","article-title":"A prospective study of prolonged central venous access in leukaemia","volume":"248","author":"Abrahm JL","year":"1982","journal-title":"Journal of the American Medical Association"},{"key":"e_1_2_1_35_2","first-page":"963","article-title":"Continuous infusion of low dose urokinase in the treatment of central venous catheter thrombosis in infants and children","volume":"83","author":"Bagnall HA","year":"1989","journal-title":"Paediatrics"},{"key":"e_1_2_1_36_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.290.6483.1708"},{"key":"e_1_2_1_37_2","doi-asserted-by":"publisher","DOI":"10.1097\/00043426-199122000-00005"},{"key":"e_1_2_1_38_2","doi-asserted-by":"publisher","DOI":"10.1128\/AAC.32.11.1627"},{"key":"e_1_2_1_39_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1980.01380020078018"},{"key":"e_1_2_1_40_2","doi-asserted-by":"publisher","DOI":"10.1177\/0148607189013005560"},{"key":"e_1_2_1_41_2","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.1987.5.4.672"},{"key":"e_1_2_1_42_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1988.01400280100019"},{"key":"e_1_2_1_43_2","first-page":"124","article-title":"Implantable venous access device","volume":"30","author":"Franceschi D","year":"1989","journal-title":"Journal of Cardiovascular Surgery"}],"container-title":["Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2044.1996.tb14972.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2044.1996.tb14972.x","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1365-2044.1996.tb14972.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T20:23:23Z","timestamp":1761683003000},"score":1,"resource":{"primary":{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/10.1111\/j.1365-2044.1996.tb14972.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1996,10]]},"references-count":42,"journal-issue":{"issue":"10","published-print":{"date-parts":[[1996,10]]}},"alternative-id":["10.1111\/j.1365-2044.1996.tb14972.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1365-2044.1996.tb14972.x","archive":["Portico"],"relation":{},"ISSN":["0003-2409","1365-2044"],"issn-type":[{"value":"0003-2409","type":"print"},{"value":"1365-2044","type":"electronic"}],"subject":[],"published":{"date-parts":[[1996,10]]}}}