{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T03:32:42Z","timestamp":1761708762935,"version":"build-2065373602"},"reference-count":21,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2005,1,10]],"date-time":"2005-01-10T00:00:00Z","timestamp":1105315200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Anaesthesia"],"published-print":{"date-parts":[[2005,2]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:p>\n                    We compared the placement of the laryngeal tube (LT) with the intubating laryngeal mask airway (ILMA) in 51 patients whose necks were stabilised by manual in\u2010line traction. Following induction of anaesthesia and neuromuscular blockade, the LT and ILMA were inserted consecutively in a randomised, crossover design. Using pressure\u2010controlled ventilation (20 cmH\n                    <jats:sub>2<\/jats:sub>\n                    O inspiratory pressure), we measured insertion attempts, time to establish positive\u2010pressure ventilation, tidal volume, gastric insufflation, and minimum airway pressure at which gas leaked around the cuff. Data were compared using Wilcoxon signed\u2010rank tests; p\u2003&lt;\u20030.05 was considered significant. Insertion was found to be more difficult with the LT (successful at first attempt in 16 patients) than with the ILMA (successful at first attempt in 42 patients, p\u2003&lt;\u20030.0001). Time required for insertion was longer for the LT (28 [23\u201335]\u2003s, median [interquartile range]) than for the ILMA (20 [15\u201325]\u2003s, p\u2003=\u20030.0009). Tidal volume was less for the LT (440 [290\u2013670] ml) than for the ILMA (630 [440\u2013750] ml, p\u2003=\u20030.013). Minimum airway pressure at which gas leak occurred and incidence of gastric insufflation were similar with two devices. In patients whose necks were stabilised with manual in\u2010line traction, insertion of the ILMA was easier and quicker than insertion of the LT and tidal volume was greater with the ILMA than the LT.\n                  <\/jats:p>","DOI":"10.1111\/j.1365-2044.2004.03958.x","type":"journal-article","created":{"date-parts":[[2005,1,10]],"date-time":"2005-01-10T04:11:28Z","timestamp":1105330288000},"page":"113-117","source":"Crossref","is-referenced-by-count":21,"title":["Comparison of the intubating laryngeal mask airway and laryngeal tube placement during manual in\u2010line stabilisation of the neck"],"prefix":"10.1111","volume":"60","author":[{"given":"R.","family":"Komatsu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"O.","family":"Nagata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.","family":"Kamata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.","family":"Yamagata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D. I.","family":"Sessler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Ozaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2005,1,10]]},"reference":[{"key":"e_1_2_9_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/0952-8180(93)90020-F"},{"key":"e_1_2_9_3_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2044.2000.01165.x"},{"key":"e_1_2_9_4_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/82.5.712"},{"key":"e_1_2_9_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000539-199911000-00042"},{"volume-title":"Instruction for Use. Laryngeal Tube (LT).","year":"2000","author":"Anonymous.","key":"e_1_2_9_6_2"},{"key":"e_1_2_9_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03017908"},{"key":"e_1_2_9_8_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aef246"},{"key":"e_1_2_9_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1994.tb04271.x"},{"key":"e_1_2_9_10_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2044.2000.01710.x"},{"key":"e_1_2_9_11_2","doi-asserted-by":"publisher","DOI":"10.1213\/01.ANE.0000100741.46539.6B"},{"volume-title":"LMA\u2010FastrachTM Instruction Manual.","year":"1997","author":"Brain AIJ","key":"e_1_2_9_12_2"},{"key":"e_1_2_9_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1987.tb04039.x"},{"key":"e_1_2_9_14_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/88.1.127"},{"key":"e_1_2_9_15_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2346.2000.00757.x"},{"key":"e_1_2_9_16_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aef241"},{"key":"e_1_2_9_17_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1399-6576.2003.00183.x"},{"key":"e_1_2_9_18_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aeg239"},{"key":"e_1_2_9_19_2","doi-asserted-by":"publisher","DOI":"10.1213\/01.ANE.0000066252.60734.4E"},{"key":"e_1_2_9_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000539-200005000-00042"},{"key":"e_1_2_9_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199904000-00012"},{"key":"e_1_2_9_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000539-200209000-00045"}],"container-title":["Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2044.2004.03958.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1365-2044.2004.03958.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T22:26:27Z","timestamp":1761690387000},"score":1,"resource":{"primary":{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/10.1111\/j.1365-2044.2004.03958.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,1,10]]},"references-count":21,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2005,2]]}},"alternative-id":["10.1111\/j.1365-2044.2004.03958.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1365-2044.2004.03958.x","archive":["Portico"],"relation":{},"ISSN":["0003-2409","1365-2044"],"issn-type":[{"type":"print","value":"0003-2409"},{"type":"electronic","value":"1365-2044"}],"subject":[],"published":{"date-parts":[[2005,1,10]]}}}