{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T03:17:02Z","timestamp":1792725422599,"version":"4.5.0"},"reference-count":6,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2007,6,12]],"date-time":"2007-06-12T00:00:00Z","timestamp":1181606400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Anaesthesia"],"published-print":{"date-parts":[[2007,7]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:p>We describe the successful use of pharyngeal oximetry with the oropharyngeal airway in two patients with severe shock in whom finger pulse oximetry failed. One patient was a 50\u2010year\u2010old man with septic shock and the other a 32\u2010year\u2010old woman with haemorrhagic shock. In both patients, an oropharyngeal airway with a paediatric pulse oximeter probe was inserted adjacent to the tracheal tube. A good waveform was obtained and oxygen saturation was 0\u20132% lower than arterial samples whereas finger pulse oximetry saturation was unobtainable or much lower than arterial oxygen saturation. Pharyngeal oxygen saturation with the oropharyngeal airway is feasible and more accurate than finger oximetry in low perfusion states.<\/jats:p>","DOI":"10.1111\/j.1365-2044.2007.05072.x","type":"journal-article","created":{"date-parts":[[2007,6,12]],"date-time":"2007-06-12T07:14:25Z","timestamp":1181632465000},"page":"734-736","source":"Crossref","is-referenced-by-count":14,"title":["Successful use of pharyngeal pulse oximetry with the oropharyngeal airway in severely shocked patients"],"prefix":"10.1111","volume":"62","author":[{"given":"H.","family":"Yu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B.","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2007,6,12]]},"reference":[{"key":"e_1_2_4_2_2","volume-title":"Recommendations for Standards of Monitoring During Anaesthesia and Recovery","author":"Adams AP","year":"1989"},{"key":"e_1_2_4_3_2","volume-title":"Standards for Basic Intra\u2010Operative Monitoring","author":"American Society of Anesthesiologists.","year":"1991"},{"key":"e_1_2_4_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0147-9563(98)90086-3"},{"key":"e_1_2_4_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000539-200002000-00037"},{"key":"e_1_2_4_6_2","first-page":"469","article-title":"Accuracy of pharyngeal pulse oximetry with different methods of application","volume":"19","author":"Kamal HM","year":"2003","journal-title":"Egyptian Journal of Anaesthesia"},{"key":"e_1_2_4_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03019674"}],"container-title":["Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2044.2007.05072.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1365-2044.2007.05072.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T21:11:17Z","timestamp":1761685877000},"score":1,"resource":{"primary":{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/10.1111\/j.1365-2044.2007.05072.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,6,12]]},"references-count":6,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2007,7]]}},"alternative-id":["10.1111\/j.1365-2044.2007.05072.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1365-2044.2007.05072.x","archive":["Portico"],"relation":{},"ISSN":["0003-2409","1365-2044"],"issn-type":[{"value":"0003-2409","type":"print"},{"value":"1365-2044","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,6,12]]}}}