{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T21:43:28Z","timestamp":1784065408008,"version":"3.55.0"},"reference-count":18,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2008,12,5]],"date-time":"2008-12-05T00:00:00Z","timestamp":1228435200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Anaesthesia"],"published-print":{"date-parts":[[2009,1]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:p>\n                    The LMA Supreme\n                    <jats:sup>TM<\/jats:sup>\n                    is a new extraglottic airway device which brings together features of the LMA ProSeal\n                    <jats:sup>TM<\/jats:sup>\n                    , Fastrach\n                    <jats:sup>TM<\/jats:sup>\n                    and Unique\n                    <jats:sup>TM<\/jats:sup>\n                    . We test the hypothesis that ease of insertion, oropharyngeal leak pressure, fibreoptic position and ease of gastric tube placement differ between the LMA ProSeal\n                    <jats:sup>TM<\/jats:sup>\n                    and the LMA Supreme\n                    <jats:sup>TM<\/jats:sup>\n                    in paralysed anesthetised patients. Ninety\u2010three females aged 19\u201371\u2003years were studied. Both devices were inserted into each patient in random order. Two attempts were allowed. Digital insertion was used for the first attempt and guided insertion for the second attempt. Oropharyngeal leak pressure and fibreoptic position were determined during cuff inflation from 0 to 40\u2003ml in 10\u2003ml increments. Gastric tube insertion was attempted if there was no gas leak from the drain tube. First attempt and overall insertion success were similar (LMA ProSeal\n                    <jats:sup>TM<\/jats:sup>\n                    , 92% and 100%; LMA Supreme\n                    <jats:sup>TM<\/jats:sup>\n                    95% and 100%). Guided insertion was always successful following failed digital insertion. Oropharyngeal leak pressure was 4\u20138\u2003ml higher for the LMA ProSeal\n                    <jats:sup>TM<\/jats:sup>\n                    over the inflation range (p\u2003&lt;\u20030.001). Intracuff pressure was 16\u201335\u2003cm higher for the LMA ProSeal\n                    <jats:sup>TM<\/jats:sup>\n                    when the cuff volume was 20\u201340\u2003ml (p\u2003&lt;\u20030.001). There was an increase in oropharyngeal leak pressure with increasing cuff volume from 10 to 30\u2003ml for both devices, but no change from 0 to 10\u2003ml and 30\u201340\u2003ml. There were no differences in the fibreoptic position of the airway or drain tube. The first attempt and overall insertion success for the gastric tube was similar (LMA ProSeal\n                    <jats:sup>TM<\/jats:sup>\n                    91% and 100%; LMA Supreme\n                    <jats:sup>TM<\/jats:sup>\n                    92% and 100%). We conclude that ease of insertion, gastric tube placement and fibreoptic position are similar for the LMA ProSeal\n                    <jats:sup>TM<\/jats:sup>\n                    and LMA Supreme\n                    <jats:sup>TM<\/jats:sup>\n                    in paralysed, anaesthetised females, but oropharyngeal leak pressure and intracuff pressure are higher for the LMA ProSeal\n                    <jats:sup>TM<\/jats:sup>\n                    .\n                  <\/jats:p>","DOI":"10.1111\/j.1365-2044.2008.05682.x","type":"journal-article","created":{"date-parts":[[2008,12,5]],"date-time":"2008-12-05T12:55:54Z","timestamp":1228481754000},"page":"79-83","source":"Crossref","is-referenced-by-count":107,"title":["The Laryngeal Mask Airway Supreme\n                    <sup>TM<\/sup>\n                    \u2013 a single use laryngeal mask airway with an oesophageal vent. A randomised, cross\u2010over study with the Laryngeal Mask Airway ProSeal\n                    <sup>TM<\/sup>\n                    in paralysed, anaesthetised patients"],"prefix":"10.1111","volume":"64","author":[{"given":"S.","family":"Eschertzhuber","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Brimacombe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Hohlrieder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Keller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2008,12,5]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/84.5.650"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/79.6.699"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000539-199810000-00033"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2007.05421.x"},{"key":"e_1_2_6_6_2","volume-title":"LMA ProSealTM Instruction Manual","author":"LMA North America Inc.","year":"2000"},{"key":"e_1_2_6_7_2","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1177\/0310057X0203000514","article-title":"Gum elastic bougie\u2010guided insertion of the ProSeal laryngeal mask airway. A new technique","volume":"30","author":"Howarth A","year":"2002","journal-title":"Anaesthesia and Intensive Care"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/82.2.286"},{"key":"e_1_2_6_9_2","first-page":"457","article-title":"A proposed fiber\u2010optic scoring system to standardize the assessment of laryngeal mask airway position","volume":"76","author":"Brimacombe J","year":"1993","journal-title":"Anesthesia and Analgesia"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/88.1.127"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0196-0644(05)82571-5"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000539-200209000-00045"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000539-200111000-00064"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/81.2.186"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/85.2.262"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X0403200514"},{"key":"e_1_2_6_17_2","volume-title":"Laryngeal Mask Anesthesia. Principles and Practice","author":"Brimacombe J","year":"2004"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03016840"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199904000-00012"}],"container-title":["Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2044.2008.05682.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1365-2044.2008.05682.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T16:38:03Z","timestamp":1761669483000},"score":1,"resource":{"primary":{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/10.1111\/j.1365-2044.2008.05682.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,12,5]]},"references-count":18,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2009,1]]}},"alternative-id":["10.1111\/j.1365-2044.2008.05682.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1365-2044.2008.05682.x","archive":["Portico"],"relation":{},"ISSN":["0003-2409","1365-2044"],"issn-type":[{"value":"0003-2409","type":"print"},{"value":"1365-2044","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,12,5]]}}}