{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T04:05:00Z","timestamp":1793851500485,"version":"4.6.1"},"reference-count":15,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2009,9,2]],"date-time":"2009-09-02T00:00:00Z","timestamp":1251849600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Anaesthesia"],"published-print":{"date-parts":[[2009,10]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:p>Ten anaesthetists assessed the ease of tracheal intubation (time to see the glottis, to intubate the trachea and to ventilate), using the Pentax Airway Scope and Macintosh laryngoscope in a manikin, in three simulated circumstances of restricted laryngoscopy: (1) the patient lying supine on the ground; (2) the patient lying supine on the ground with the head close to a wall; (3) the patient confined to a car driver\u2019s seat. For the Pentax Airway Scope, intubation was successful (within 2\u2003min) in all three circumstances. For the Macintosh laryngoscope, intubation was successful in all cases in circumstance (1), eight in circumstance (2), and five in circumstance (3). In circumstances (2) and (3), the Pentax Airway Scope needed significantly shorter time to see the vocal cords (median [95% confidence interval] for difference: 4.5 [0.5\u20139.5]\u2003s in circumstance (2), and 12.5 [7.0\u201332.5]\u2003s in circumstance (3)), shorter time to intubate (median [95% confidence interval] for difference: 21.0 [5.5\u201338.5]\u2003s in circumstance (2), and 40.5 [17.5\u201364.0]\u2003s in circumstance (3)), and shorter time to ventilate the lungs (median [95% confidence interval] for difference: 18. 3 [4.5\u201336.0]\u2003s in circumstance (2), and 47.5 [16.0\u201384.5]\u2003s in circumstance (3)). These results indicate that, in situations where access to the patient\u2019s head is restricted, the Pentax Airway Scope is more effective than the Macintosh laryngoscope.<\/jats:p>","DOI":"10.1111\/j.1365-2044.2009.06014.x","type":"journal-article","created":{"date-parts":[[2009,9,2]],"date-time":"2009-09-02T08:05:12Z","timestamp":1251878712000},"page":"1114-1117","source":"Crossref","is-referenced-by-count":43,"title":["Tracheal intubation with restricted access: a randomised comparison of the Pentax\u2010Airway Scope and Macintosh laryngoscope in a manikin"],"prefix":"10.1111","volume":"64","author":[{"given":"T.","family":"Asai","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2009,9,2]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1997.01430300034007"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0196-0644(85)80927-6"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.2.3645.817"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aei275"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0300-9572(02)00293-9"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03012914"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/00008506-200610000-00005"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2006.08.026"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1213\/01.ane.0000287647.46165.bc"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2007.04967.x"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aen002"},{"key":"e_1_2_6_13_2","first-page":"341","article-title":"Use of the Pentax\u2010AWS in a patient with Cormack3a difficult airway","volume":"56","author":"Suzuki A","year":"2007","journal-title":"Masui (Japanese Journal Anesthesiology)"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinane.2007.01.001"},{"key":"e_1_2_6_15_2","first-page":"862","article-title":"Pentax AWS Airway Scope","volume":"56","author":"Asai T","year":"2007","journal-title":"Masui (Japanese Journal Anesthesiology)"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0b013e31819c45e5"}],"container-title":["Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2044.2009.06014.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1365-2044.2009.06014.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T00:54:08Z","timestamp":1761699248000},"score":1,"resource":{"primary":{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/10.1111\/j.1365-2044.2009.06014.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,9,2]]},"references-count":15,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2009,10]]}},"alternative-id":["10.1111\/j.1365-2044.2009.06014.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1365-2044.2009.06014.x","archive":["Portico"],"relation":{},"ISSN":["0003-2409","1365-2044"],"issn-type":[{"value":"0003-2409","type":"print"},{"value":"1365-2044","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,9,2]]}}}