{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T12:49:32Z","timestamp":1783342172464,"version":"3.54.6"},"reference-count":28,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2010,3,19]],"date-time":"2010-03-19T00:00:00Z","timestamp":1268956800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Anaesthesia"],"published-print":{"date-parts":[[2010,5]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:p>A safety\u2010orientated system of delivering parenteral anaesthetic drugs was assessed in a prospective incident monitoring study at two hospitals. Anaesthetists completed an incident form for every anaesthetic, indicating if an incident occurred. Case mix data were collected and the number of drug administrations made during procedures estimated. From February 1998 at Hospital A and from June 1999 at Hospital B, until November 2003, 74\u2003478 anaesthetics were included, for which 59\u2003273 incident forms were returned (a 79.6% response rate). Fewer parenteral drug errors occurred with the new system than with conventional methods (58 errors in an estimated 183\u2003852 drug administrations (0.032%, 95% CI 0.024\u20130.041%) vs 268 in 550\u2003105 (0.049%, 95% CI 0.043\u20130.055%) respectively, p\u2003=\u20030.002), a relative reduction of 35% (difference 0.017%, 95% CI 0.006\u20130.028%). No major adverse outcomes from these errors were reported with the new system while 11 (0.002%) were reported with conventional methods (p\u2003=\u20030.055). We conclude that targeted system re\u2010design can reduce medical error.<\/jats:p>","DOI":"10.1111\/j.1365-2044.2010.06325.x","type":"journal-article","created":{"date-parts":[[2010,3,20]],"date-time":"2010-03-20T20:15:32Z","timestamp":1269116132000},"page":"490-499","source":"Crossref","is-referenced-by-count":88,"title":["Clinical assessment of a new anaesthetic drug administration system: a prospective, controlled, longitudinal incident monitoring study*"],"prefix":"10.1111","volume":"65","author":[{"given":"C. S.","family":"Webster","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Larsson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C. M.","family":"Frampton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Weller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"McKenzie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.","family":"Cumin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A. F.","family":"Merry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2010,4,12]]},"reference":[{"key":"e_1_2_7_2_2","author":"Institute of Medicine","year":"2000","journal-title":"To Err Is Human \u2013 Building a Safer Health System"},{"key":"e_1_2_7_3_2","author":"Department of Health","year":"2000","journal-title":"An Organisation With A Memory \u2013 Report Of An Expert Group On Learning From Adverse Events In The NHS"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1080\/08109020500209946"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X0102900508"},{"key":"e_1_2_7_6_2","first-page":"A1358","article-title":"Anesthesia drug administration error in a university hospital","volume":"99","author":"Bowdle A","year":"2003","journal-title":"Anesthesiology"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000539-200108000-00030"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2004.03457.x"},{"key":"e_1_2_7_9_2","first-page":"9119","article-title":"Bar code label requirement for human drug products and biological products","volume":"69","author":"Anonymous","year":"2004","journal-title":"Federal Register"},{"key":"e_1_2_7_10_2","author":"Anonymous","year":"1995","journal-title":"Standard Specification for User Applied Drug Labels in Anesthesiology (D4774-94)"},{"key":"e_1_2_7_11_2","unstructured":"Anonymous.Anaesthetic and respiratory equipment \u2013 user\u2010applied labels for syringes containing drugs used during anaesthesia \u2013 colours design and performance (ISO 26825:2008): International Organization for Standardization 2008.http:\/\/www.iso.org. (accessed 09\/11\/2009)."},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2007.04993.x"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2005.04331.x"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-200207000-00020"},{"key":"e_1_2_7_15_2","author":"Anonymous","year":"1996","journal-title":"User-applied Labels for Use on Syringes Containing Drugs Used During Anaesthesia (AS\/NZS 4375:1996)"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.323.7308.298"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1017\/CBO9780511806063"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1177\/001872679905200401"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X0903700105"},{"key":"e_1_2_7_20_2","author":"Webster CS","year":"2008","journal-title":"Implementing Safety in Medicine \u2013 the Problem, the Pitfalls and a Successful Safety Initiative in Anaesthesia"},{"key":"e_1_2_7_21_2","author":"Salas E","year":"1999","journal-title":"Human-Technology Interaction in Complex Systems"},{"key":"e_1_2_7_22_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2044.2000.01664-27.x"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.1017\/S0265021506001670"},{"key":"e_1_2_7_24_2","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-138-12-200306170-00009"},{"key":"e_1_2_7_25_2","author":"Runciman B","year":"2007","journal-title":"Safety and Ethics in Healthcare \u2013 a Guide to Getting it Right"},{"key":"e_1_2_7_26_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2004.03670.x"},{"key":"e_1_2_7_27_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2005.04301.x"},{"key":"e_1_2_7_28_2","first-page":"185","article-title":"Anaesthetists, errors in drug administration and the law","volume":"108","author":"Merry AF","year":"1995","journal-title":"New Zealand Medical Journal"},{"key":"e_1_2_7_29_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.0003-2409.2001.02397.x"}],"container-title":["Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2044.2010.06325.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1365-2044.2010.06325.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T21:07:41Z","timestamp":1761685661000},"score":1,"resource":{"primary":{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/10.1111\/j.1365-2044.2010.06325.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,4,12]]},"references-count":28,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2010,5]]}},"alternative-id":["10.1111\/j.1365-2044.2010.06325.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1365-2044.2010.06325.x","archive":["Portico"],"relation":{},"ISSN":["0003-2409","1365-2044"],"issn-type":[{"value":"0003-2409","type":"print"},{"value":"1365-2044","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,4,12]]}}}