{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T14:05:21Z","timestamp":1761919521211,"version":"build-2065373602"},"reference-count":29,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2012,2,21]],"date-time":"2012-02-21T00:00:00Z","timestamp":1329782400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Anaesthesia"],"published-print":{"date-parts":[[2012,6]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:p>\n                    We performed a prospective, randomised trial comparing the i\u2010gel\n                    <jats:sup>TM<\/jats:sup>\n                    with the LMA Classic\n                    <jats:sup>TM<\/jats:sup>\n                    in children undergoing general anaesthesia. Ninety\u2010nine healthy patients were randomly assigned to either the i\u2010gel or the LMA Classic. The outcomes measured were airway leak pressure, ease of insertion, time taken for insertion, fibreoptic examination and complications. Median (IQR [range]) time to successful device placement was shorter with the i\u2010gel (17.0 (13.8\u221220.0 [10.0\u221220.0]) s) compared with the LMA Classic (21.0 (17.5\u221225.0 [15.0\u221270.0])\u2003s, p\u2003=\u20030.002). There was no significant difference in oropharyngeal leak pressure between the two devices. A good fibreoptic view of the glottis was obtained in 74% of the i\u2010gel group and in 43% of the LMA Classic group (p\u2003&lt;\u20030.001). There were no significant complications. In conclusion, the i\u2010gel provided a similar leak pressure, but a shorter insertion time and improved glottic view compared with the LMA Classic in children.\n                  <\/jats:p>","DOI":"10.1111\/j.1365-2044.2012.07072.x","type":"journal-article","created":{"date-parts":[[2012,2,21]],"date-time":"2012-02-21T13:36:52Z","timestamp":1329831412000},"page":"606-611","source":"Crossref","is-referenced-by-count":72,"title":["A randomised trial comparing the i\u2010gel\n                    <sup>TM<\/sup>\n                    with the LMA Classic\n                    <sup>TM<\/sup>\n                    in children"],"prefix":"10.1111","volume":"67","author":[{"given":"J.\u2010R.","family":"Lee","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.\u2010S.","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.\u2010T.","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.\u2010J.","family":"Byon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Y.\u2010H.","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.\u2010S.","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.\u2010S.","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2012,2,21]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.2009.02997.x"},{"key":"e_1_2_6_3_2","unstructured":"Intersurgical i\u2010gel User Guide.http:\/\/www.i\u2010gel.com(accessed 01\/10\/2011)."},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1017\/S0265021508004511"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2009.05898.x"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aep292"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2009.06017.x"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1213\/ANE.0b013e3181b6496a"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2010.06534.x"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/EJA.0b013e3283340a81"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1992.tb03144.x"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03014975"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.2008.01869.x"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0b013e318219d619"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2011.06884.x"},{"volume-title":"Recommendations for standards of monitoring during anaesthesia","year":"2007","author":"Association of Anaesthetists of Great Britain and Ireland","key":"e_1_2_6_16_2"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aei167"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/79.6.710"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1213\/01.ANE.0000133916.10017.6D"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0b013e3181a4c6b9"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.2008.02434.x"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/ACO.0b013e3283294d06"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/86.1.122"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aeh238"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.2010.03277.x"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.2009.03109.x"},{"key":"e_1_2_6_27_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.2008.02706.x"},{"key":"e_1_2_6_28_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199212000-00007"},{"key":"e_1_2_6_29_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2002.00815.x"},{"key":"e_1_2_6_30_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.2010.03284.x"}],"container-title":["Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2044.2012.07072.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1365-2044.2012.07072.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T19:53:34Z","timestamp":1761681214000},"score":1,"resource":{"primary":{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/10.1111\/j.1365-2044.2012.07072.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,2,21]]},"references-count":29,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2012,6]]}},"alternative-id":["10.1111\/j.1365-2044.2012.07072.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1365-2044.2012.07072.x","archive":["Portico"],"relation":{},"ISSN":["0003-2409","1365-2044"],"issn-type":[{"type":"print","value":"0003-2409"},{"type":"electronic","value":"1365-2044"}],"subject":[],"published":{"date-parts":[[2012,2,21]]}}}