{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T02:47:24Z","timestamp":1772160444960,"version":"3.50.1"},"reference-count":29,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2011,4,22]],"date-time":"2011-04-22T00:00:00Z","timestamp":1303430400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Br J Haematol"],"published-print":{"date-parts":[[2011,6]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:p>\n                    Quantitative computed tomography (QCT) has been proposed for iron quantification for more than 30\u2003years, however there has been little clinical validation. We compared liver attenuation by QCT with magnetic resonance imaging (MRI)\u2010derived estimates of liver iron concentration (LIC) in 37 patients with transfusional siderosis. MRI and QCT measurements were performed as clinically indicated monitoring of LIC and vertebral bone\u2010density respectively, over a 6\u2010year period. Mean time difference between QCT and MRI studies was 14\u2003d, with 25 studies performed on the same day. For liver attenuation outside the normal range, attenuation values rose linearly with LIC (\n                    <jats:italic>r<\/jats:italic>\n                    <jats:sup>2<\/jats:sup>\n                    \u2003=\u20030\u00b794). However, intersubject variability in intrinsic liver attenuation prevented quantitation of LIC &lt;8\u2003mg\/g dry weight of liver, and was the dominant source of measurement uncertainty. Calculated QCT and MRI accuracies were equivalent for LIC values approaching 22\u2003mg\/g dry weight, with QCT having superior performance at higher LIC\u2019s. Although not suitable for monitoring patients with good iron control, QCT may nonetheless represent a viable technique for liver iron quantitation in patients with moderate to severe iron in regions where MRI resources are limited because of its low cost, availability, and high throughput.\n                  <\/jats:p>","DOI":"10.1111\/j.1365-2141.2011.08590.x","type":"journal-article","created":{"date-parts":[[2011,4,22]],"date-time":"2011-04-22T01:38:30Z","timestamp":1303436310000},"page":"780-785","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Quantitative computed tomography assessment of transfusional iron overload"],"prefix":"10.1111","volume":"153","author":[{"given":"John C.","family":"Wood","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ashley","family":"Mo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aakansha","family":"Gera","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Montre","family":"Koh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Coates","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vicente","family":"Gilsanz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2011,4,22]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/0168-8278(95)80060-3"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM200008033430503"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/0016-5085(90)90629-F"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199409013310902"},{"key":"e_1_2_6_6_1","first-page":"250","volume-title":"Expanding the Role of Medical Physics in Nuclear Medicine","author":"Cann C.","year":"1991"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.280.6212.440"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF01888728"},{"key":"e_1_2_6_9_1","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1093\/clinchem\/45.3.340","article-title":"Quantitative study of the variability of hepatic iron concentrations","volume":"45","author":"Emond M.J.","year":"1999","journal-title":"Clinical Chemistry"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1182\/blood-2006-03-013482"},{"key":"e_1_2_6_11_1","article-title":"Relaxivity\u2010iron calibration in hepatic iron overload: probing underlying biophysical mechanisms using a Monte Carlo model","author":"Ghugre N.R.","year":"2010","journal-title":"Magnetic Resonance In Medicine"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2493080206"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/00004424-198207000-00013"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/0016-5085(89)90646-X"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.2169\/internalmedicine.31.180"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2008.07.014"},{"key":"e_1_2_6_17_1","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/S0016-5085(83)80113-9","article-title":"Diagnostic efficacy of hepatic computed tomography in the detection of body iron overload","volume":"84","author":"Howard J.M.","year":"1983","journal-title":"Gastroenterology"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF01623841"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.sult.2010.05.004"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1097\/00004424-199204000-00012"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1182\/blood-2008-04-148767"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1182\/blood.V89.3.739"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3476(89)80564-5"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/pbc.21275"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0609.2007.00985.x"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1182\/blood-2004-01-0177"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0609.2009.01228.x"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2141.2000.02298.x"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1182\/blood-2004-10-3982"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/0009-8981(78)90387-X"}],"container-title":["British Journal of Haematology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2141.2011.08590.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1365-2141.2011.08590.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T20:21:53Z","timestamp":1697401313000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1365-2141.2011.08590.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,4,22]]},"references-count":29,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2011,6]]}},"alternative-id":["10.1111\/j.1365-2141.2011.08590.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1365-2141.2011.08590.x","archive":["Portico"],"relation":{"has-review":[{"id-type":"doi","id":"10.3410\/f.10696956.11583059","asserted-by":"object"}]},"ISSN":["0007-1048","1365-2141"],"issn-type":[{"value":"0007-1048","type":"print"},{"value":"1365-2141","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,4,22]]},"assertion":[{"value":"2011-04-22","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}