{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T00:54:53Z","timestamp":1787014493902,"version":"build-2736575974"},"reference-count":48,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2010,2,8]],"date-time":"2010-02-08T00:00:00Z","timestamp":1265587200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Int Endodontic J"],"published-print":{"date-parts":[[2010,3]]},"abstract":"<jats:sec>\n                    <jats:label\/>\n                    <jats:p>\n                      <jats:bold>Camilleri J.<\/jats:bold>\n                      Evaluation of the physical properties of an endodontic Portland cement incorporating alternative radiopacifiers used as root\u2010end filling material.\n                      <jats:italic>International Endodontic Journal<\/jats:italic>\n                      ,\n                      <jats:bold>43<\/jats:bold>\n                      , 231\u2013240, 2010.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Abstract<\/jats:title>\n                    <jats:p>\n                      <jats:bold>Aim\u2002<\/jats:bold>\n                      To investigate the physical and chemical properties of Portland cement (PC) loaded with alternative radiopacifying materials for use as root\u2010end filling materials in a mineral trioxide aggregate (MTA)\u2010like system.\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>Methodology\u2002<\/jats:bold>\n                      Portland cement loaded with barium sulphate, gold and silver\/tin alloy was mixed with water, and the physical and chemical properties of the hydrated cements were evaluated. MTA and intermediate restorative material (IRM) were used as controls. The radiopacity was compared to the equivalent thickness of aluminium, and the setting time of the cements was assessed using an indentation technique. The compressive strength and the stress\u2013strain relationship were determined at 28\u2003days. The stress\u2013strain relationship was determined by monitoring the strain generated when the cement was subjected to compressive load. In addition, the pH was determined in water and simulated body fluid for a period of 28\u2003days.\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>Results\u2002<\/jats:bold>\n                      The radiopacity of the cements using alternative radiopacifiers was comparable to MTA (\n                      <jats:italic>P<\/jats:italic>\n                      \u2003&gt;\u20030.05). IRM demonstrated a higher radiopacity than all the materials tested (\n                      <jats:italic>P<\/jats:italic>\n                      \u2003&lt;\u20030.05). All the cements with the exception of IRM exhibited an alkaline pH and had an extended setting time when compared to IRM. MTA had a longer setting time than the PC (\n                      <jats:italic>P<\/jats:italic>\n                      \u2003&lt;\u20030.001), and its setting time was similar to the gold\u2010loaded cement (\n                      <jats:italic>P<\/jats:italic>\n                      \u2003=\u20030.159). The addition of a radiopacifier retarded the setting time (\n                      <jats:italic>P<\/jats:italic>\n                      \u2003&lt;\u20030.001) but did not have any effect on the compressive strength as all loaded cements had comparable strength to PC (\n                      <jats:italic>P<\/jats:italic>\n                      \u2003&gt;\u20030.05). IRM was the weakest cement tested (\n                      <jats:italic>P<\/jats:italic>\n                      \u2003&lt;\u20030.001). The cement loaded with gold radiopacifier had comparable strength to MTA (\n                      <jats:italic>P<\/jats:italic>\n                      \u2003=\u20031). The stress\u2013strain relationship was linear for all the cements with IRM generating more strain on loading.\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>Conclusions\u2002<\/jats:bold>\n                      Within the parameters set in this study, bismuth oxide in MTA can be replaced by gold or silver\/tin alloy. The physical, mechanical and chemical properties of the cement replaced with alternative radiopacifiers were similar and comparable to ProRoot MTA.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/j.1365-2591.2009.01670.x","type":"journal-article","created":{"date-parts":[[2010,2,8]],"date-time":"2010-02-08T05:10:05Z","timestamp":1265605805000},"page":"231-240","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":92,"title":["Evaluation of the physical properties of an endodontic Portland cement incorporating alternative radiopacifiers used as root\u2010end filling material"],"prefix":"10.1111","volume":"43","author":[{"given":"J.","family":"Camilleri","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2010,2,8]]},"reference":[{"key":"e_1_2_7_2_1","unstructured":"American Standards for Testing MaterialsStandard Test Method for Time of Setting of Hydraulic\u2010Cement Paste by Gillmore Needles. ASTM C266\u201008."},{"key":"e_1_2_7_3_1","unstructured":"ANSI\/ADASpecification #57 section 5.6 (2008)Laboratory Testing Methods: Endodontic Filling and Sealing Materials."},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joen.2007.06.012"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/0030-4220(81)90062-1"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joen.2008.12.018"},{"key":"e_1_2_7_7_1","unstructured":"British Standard Institution(2000)Cement\u2010Part 1: Composition Specifications and Conformity Criteria for Common Cements. BS EN 197\u20101."},{"key":"e_1_2_7_8_1","unstructured":"British Standard Institution(2005)Methods of Testing Cement. Determination of Setting Time and Soundness. BS EN 196\u20103."},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2591.2007.01248.x"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2591.2007.01330.x"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2591.2007.01370.x"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2591.2009.01621.x"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.dental.2005.06.005"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.don.0000157993.89164.be"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2591.2003.00682.x"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cemconres.2007.08.008"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joen.2006.11.018"},{"key":"e_1_2_7_18_1","unstructured":"CoomaraswamyKS LumleyPJ HofmannMP(2008)Effect of Cement Paste Dilution on the Radiopacity of MTA. London UK:Pan European Federation for Dental ResearchAbstract 0613."},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2591.2006.01076.x"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1067\/moe.2003.12"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1097\/00004770-200312000-00007"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.DON.0000140566.97319.3e"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1098\/rsta.1921.0006"},{"key":"e_1_2_7_24_1","volume-title":"Endodontic Practice","author":"Grossman LI","year":"1988"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.4324\/9780203478981"},{"key":"e_1_2_7_26_1","unstructured":"International Standards Organization(2002)Dental Root Canal Sealing Materials. BS EN ISO 6876\u20107.8."},{"key":"e_1_2_7_27_1","unstructured":"International Standards Organization(2007)Dentistry: Water\u2010Based Cements. Part 1: Powder\/Liquid Acid\u2013Base Cements. BS EN ISO 9917\u20101."},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joen.2005.10.043"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tripleo.2007.08.001"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2006.01.017"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2591.2000.00281.x"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0099-2399(06)81282-3"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(03)00591-X"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2591.2007.01236.x"},{"key":"e_1_2_7_35_1","volume-title":"Properties of Concrete","author":"Neville AM","year":"1981"},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2591.1994.tb00260.x"},{"key":"e_1_2_7_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1079-2104(05)80313-0"},{"key":"e_1_2_7_38_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2591.2008.01512.x"},{"key":"e_1_2_7_39_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2591.2005.00963.x"},{"key":"e_1_2_7_40_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joen.2008.03.002"},{"key":"e_1_2_7_41_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1079-2104(96)80028-X"},{"key":"e_1_2_7_42_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(97)70179-3"},{"key":"e_1_2_7_43_1","doi-asserted-by":"publisher","DOI":"10.1590\/S1678-77572008000600004"},{"key":"e_1_2_7_44_1","unstructured":"TorabinejadM WhiteDJ(1995)Tooth Filling Material and Use. US Patent Number 5 769 638."},{"key":"e_1_2_7_45_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0099-2399(06)80967-2"},{"key":"e_1_2_7_46_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0099-2399(06)81112-X"},{"key":"e_1_2_7_47_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0099-2399(97)80051-9"},{"key":"e_1_2_7_48_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0300-5712(98)00025-6"},{"key":"e_1_2_7_49_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2005.04.025"}],"container-title":["International Endodontic Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2591.2009.01670.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1365-2591.2009.01670.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,14]],"date-time":"2023-10-14T16:55:56Z","timestamp":1697302556000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1365-2591.2009.01670.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,2,8]]},"references-count":48,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2010,3]]}},"alternative-id":["10.1111\/j.1365-2591.2009.01670.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1365-2591.2009.01670.x","archive":["Portico"],"relation":{},"ISSN":["0143-2885","1365-2591"],"issn-type":[{"value":"0143-2885","type":"print"},{"value":"1365-2591","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,2,8]]},"assertion":[{"value":"2010-02-08","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}