{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T19:49:07Z","timestamp":1785354547718,"version":"3.55.0"},"reference-count":28,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2010,7,1]],"date-time":"2010-07-01T00:00:00Z","timestamp":1277942400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Int Endodontic J"],"published-print":{"date-parts":[[2010,9]]},"abstract":"<jats:sec><jats:label\/><jats:p> <jats:bold>Kamburo\u011flu K, Kursun S.<\/jats:bold> A comparison of the diagnostic accuracy of CBCT images of different voxel resolutions used to detect simulated small internal resorption cavities. <jats:italic>International Endodontic Journal<\/jats:italic>, <jats:bold>43<\/jats:bold>, 798\u2013807, 2010.<\/jats:p><\/jats:sec><jats:sec><jats:title>Abstract<\/jats:title><jats:p><jats:bold>Aim\u2002<\/jats:bold> To assess <jats:italic>ex vivo<\/jats:italic> the use of two different cone\u2010beam computerized tomography (CBCT) units at different voxel resolutions for the detection of simulated small internal resorption cavities.<\/jats:p><jats:p><jats:bold>Methodology\u2002<\/jats:bold> A total of 60 single\u2010rooted mandibular incisors and canines were split mesiodistally along the coronal plane into labial and lingual sections. Artificial internal root resorption was simulated by drilling with a 0.5\u2010mm\u2010diameter round bur to its full depth at either the cervical or apical portion of the labial wall. In total, 60 cavities were created (30 cervical and 30 apical), and 60 locations (30 cervical and 30 apical) were left without cavities. The sections were rejoined and placed in dry human mandibles in groups of 6 and imaged using two different CBCT units at different resolutions to obtain five image sets as follows: Iluma, ultra\u2010resolution (0.1\u2003mm<jats:sup>3<\/jats:sup>); Iluma, high\u2010resolution (0.2\u2003mm<jats:sup>3<\/jats:sup>); Iluma, low\u2010resolution (0.3\u2003mm<jats:sup>3<\/jats:sup>); 3D Accuitomo 170, 6\u2003\u00d7 6\u2003cm FOV (0.125\u2003mm<jats:sup>3<\/jats:sup>); 3D Accuitomo 170, 8\u2003\u00d7\u20038\u2003cm FOV (0.160\u2003mm<jats:sup>3<\/jats:sup>). Each image set was viewed by two observers and evaluated using a 5\u2010point scale for detection of internal resorption cavities. Kappa coefficients were calculated to assess intra\u2010 and inter\u2010observer agreement. Az values were calculated and compared, with a significance level of \u03b1\u2003=\u20030.05.<\/jats:p><jats:p><jats:bold>Results\u2002<\/jats:bold> Kappa values were fair\u2010to\u2010moderate for the low\u2010resolution Iluma images and good to excellent for all other image sets. Both intra\u2010 and inter\u2010observer agreement values were higher for the Accuitomo images than for the Iluma images. The highest Az values were obtained with the Accuitomo 0.125\u2003mm<jats:sup>3<\/jats:sup> images and the lowest with the Iluma 0.3\u2003mm<jats:sup>3<\/jats:sup> images. The Az values for the Accuitomo and Iluma ultra\u2010 and high\u2010resolution images were higher than those of the low\u2010resolution Iluma images. No differences (<jats:italic>P<\/jats:italic>\u2003&gt;\u20030.05) for internal resorption detection were found between the Az values of the Accuitomo 0.125\u2003mm<jats:sup>3<\/jats:sup>, Accuitomo 0.160\u2003mm<jats:sup>3<\/jats:sup>, ultra\u2010resolution Iluma and high\u2010resolution Iluma images.<\/jats:p><jats:p><jats:bold>Conclusion\u2002<\/jats:bold> Ultra\u2010and high\u2010resolution Iluma and Accuitomo 0.125 and 0.160\u2003mm<jats:sup>3<\/jats:sup> CBCT images performed similarly and better than low\u2010resolution Iluma images in the detection of simulated internal resorption <jats:italic>ex vivo<\/jats:italic>.<\/jats:p><\/jats:sec>","DOI":"10.1111\/j.1365-2591.2010.01749.x","type":"journal-article","created":{"date-parts":[[2010,7,6]],"date-time":"2010-07-06T17:45:59Z","timestamp":1278438359000},"page":"798-807","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":76,"title":["A comparison of the diagnostic accuracy of CBCT images of different voxel resolutions used to detect simulated small internal resorption cavities"],"prefix":"10.1111","volume":"43","author":[{"given":"K.","family":"Kamburo\u011flu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Kursun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2010,8,3]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajodo.2009.03.036"},{"key":"e_1_2_7_3_1","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/S0011-8532(22)02509-5","article-title":"Root resorption","volume":"36","author":"Bakland LF","year":"1992","journal-title":"Dental Clinics of North America"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2591.1999.00172.x"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0099-2399(98)80056-3"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/00004770-200112000-00022"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1079-2104(99)70002-8"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2591.1999.00252.x"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/23424132"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1038\/sj.dmfr.4600626"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tripleo.2007.05.030"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/57348961"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-9657.2002.00012.x"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joen.2008.11.005"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/60375385"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tripleo.2008.03.018"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.14219\/jada.archive.2008.0339"},{"key":"e_1_2_7_18_1","first-page":"9","article-title":"Tooth resorption","volume":"30","author":"Ne RF","year":"1999","journal-title":"Quintessence International"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2591.2007.01247.x"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2591.2008.01530.x"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2591.2009.01592.x"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cden.2008.05.005"},{"key":"e_1_2_7_23_1","first-page":"75","article-title":"Clinical applications of cone\u2010beam computed tomography in dental practice","volume":"72","author":"Scarfe WC","year":"2006","journal-title":"Journal of Canadian Dental Association"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-9657.1988.tb00642.x"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1601-1546.2002.10106.x"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cden.2008.05.002"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-9657.1985.tb00584.x"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.HP.0000326340.81581.1a"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cden.2008.05.006"}],"container-title":["International Endodontic Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2591.2010.01749.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1365-2591.2010.01749.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,30]],"date-time":"2023-10-30T05:35:59Z","timestamp":1698644159000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1365-2591.2010.01749.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,8,3]]},"references-count":28,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2010,9]]}},"alternative-id":["10.1111\/j.1365-2591.2010.01749.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1365-2591.2010.01749.x","archive":["Portico"],"relation":{},"ISSN":["0143-2885","1365-2591"],"issn-type":[{"value":"0143-2885","type":"print"},{"value":"1365-2591","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,8,3]]},"assertion":[{"value":"2010-08-03","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}