{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T03:50:24Z","timestamp":1790049024313,"version":"4.0.1"},"reference-count":19,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2005,11,2]],"date-time":"2005-11-02T00:00:00Z","timestamp":1130889600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Advanced Nursing"],"published-print":{"date-parts":[[2005,12]]},"abstract":"<jats:p><jats:bold>Aim.\u2002<\/jats:bold> This paper reports an audit of the effect on admission temperatures of using occlusive polyethylene wrap applied immediately after the birth of extremely premature infants.<\/jats:p><jats:p><jats:bold>Background.\u2002<\/jats:bold> Use of occlusive polyethylene wrap during the early postnatal management of the premature infant reduces evaporative and convective heat loss.<\/jats:p><jats:p><jats:bold>Method.\u2002<\/jats:bold> Retrospective preintervention audit was carried out, followed by the introduction of occlusive polyethylene wrap for thermal management during resuscitation and early stabilization. Prospective postintervention audit was then performed. The preintervention (control) group infants were immediately dried with prewarmed towels and resuscitated under radiant heat. Infants in the intervention group were managed under radiant heat, were not dried but were immediately enclosed in an occlusive polyethylene wrap.<\/jats:p><jats:p><jats:bold>Results.\u2002<\/jats:bold> The demographic characteristics of the two groups were comparable. Use of occlusive polyethylene wrap resulted in higher admission temperatures for infants less than 27\u2003weeks gestation (<jats:italic>z<\/jats:italic>\u2003=\u2003108\u00b750, <jats:italic>P<\/jats:italic>\u2003&lt;\u20030\u00b701). There was no statistically significant improvement in admission temperatures for 27\u201329\u2003week infants. The rate of hypothermia on admission (&lt;35\u00b76\u00b0C per axilla) was lower in the intervention group (<jats:italic>\u03c7<\/jats:italic><jats:sup>2<\/jats:sup>\u2003=\u20035\u00b712, d.f.\u2003=\u20031, <jats:italic>P<\/jats:italic>\u2003=\u20030\u00b702), but more infants recorded temperatures exceeding 37\u00b72\u00b0C during the first 12\u2003hours (<jats:italic>\u03c7<\/jats:italic><jats:sup>2<\/jats:sup>\u2003=\u200323\u00b745, d.f.\u2003=\u20031, <jats:italic>P<\/jats:italic>\u2003&lt;\u20030\u00b701). There were no other adverse effects noted.<\/jats:p><jats:p><jats:bold>Conclusion.\u2002<\/jats:bold> Use of occlusive polyethylene wrap improved admission temperatures for infants less than 27\u2003weeks gestation. This intervention is easy to implement and does not interfere with resuscitation. However, removal of the wrap should be considered following admission to a closed care system in the neonatal intensive care unit because, in the intervention group, hyperthermia in the first 12\u2003hours was a potential side effect.<\/jats:p>","DOI":"10.1111\/j.1365-2648.2005.03616.x","type":"journal-article","created":{"date-parts":[[2005,11,2]],"date-time":"2005-11-02T15:53:37Z","timestamp":1130946817000},"page":"482-489","source":"Crossref","is-referenced-by-count":17,"title":["Thermal management for premature births"],"prefix":"10.1111","volume":"52","author":[{"given":"Sandie","family":"Bredemeyer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shelley","family":"Reid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michele","family":"Wallace","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2005,11,2]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(68)92105-3"},{"key":"e_1_2_9_3_1","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1542\/peds.74.6.1022","article-title":"Reduction of oxygen consumption, insensible water loss, and radiant heat demand with use of a plastic blanket for low\u2010birth\u2010weight infants under radiant warmers","volume":"74","author":"Baumgart S.","year":"1984","journal-title":"Pediatrics"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3476(81)80030-3"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM197101212840302"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1067\/mpd.2000.107631"},{"key":"e_1_2_9_7_1","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1177\/004947559602600110","article-title":"Trial of polythene tobacco\u2010wrap in prevention of hypothermia in neonates less than 1500\u2003grams","volume":"26","author":"Bosch C.A.","year":"1996","journal-title":"Tropical Doctor"},{"issue":"1","key":"e_1_2_9_8_1","first-page":"10","article-title":"Clinical audit of a small baby protocol for infants born before 26\u2003weeks gestation","volume":"4","author":"Bredemeyer S.L.","year":"2001","journal-title":"Neonatal, Paediatric and Child Health Nursing"},{"key":"e_1_2_9_9_1","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1542\/peds.34.2.163","article-title":"Effect of maintenance of \u2018\u2018normal\u2019\u2019 skin temperature on survival of infants of low birth weight","volume":"34","author":"Buetow K.C.","year":"1964","journal-title":"Pediatrics"},{"key":"e_1_2_9_10_1","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1542\/peds.49.4.504","article-title":"Newborn temperature and calculated heat loss in the delivery room","volume":"49","author":"Dahm L.S.","year":"1972","journal-title":"Pediatrics"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1136\/fn.78.2.F85"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9378(91)90638-8"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3476(62)80174-7"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.99.14.1927"},{"key":"e_1_2_9_15_1","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1542\/peds.83.6.945","article-title":"Semipermeable polyurethane membrane as an artificial skin for the premature neonate","volume":"83","author":"Knauth A.","year":"1989","journal-title":"Pediatrics"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0929-693X(01)00759-X"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9378(66)90034-2"},{"key":"e_1_2_9_18_1","volume-title":"When Does Quality Assurance in Health Care Require Independent Ethical Review","author":"National Health & Medical Research Council","year":"2003"},{"key":"e_1_2_9_19_1","doi-asserted-by":"crossref","first-page":"876","DOI":"10.1542\/peds.22.5.876","article-title":"The influence of the thermal environment upon the survival of newly born preterm infants","volume":"22","author":"Silverman W.A.","year":"1958","journal-title":"Pediatrics"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3476(99)70238-6"}],"container-title":["Journal of Advanced Nursing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2648.2005.03616.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1365-2648.2005.03616.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T07:17:30Z","timestamp":1697354250000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1365-2648.2005.03616.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,11,2]]},"references-count":19,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2005,12]]}},"alternative-id":["10.1111\/j.1365-2648.2005.03616.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1365-2648.2005.03616.x","archive":["Portico"],"relation":{},"ISSN":["0309-2402","1365-2648"],"issn-type":[{"value":"0309-2402","type":"print"},{"value":"1365-2648","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,11,2]]}}}