{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,8,9]],"date-time":"2024-08-09T05:07:52Z","timestamp":1723180072077},"reference-count":28,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2009,8,3]],"date-time":"2009-08-03T00:00:00Z","timestamp":1249257600000},"content-version":"vor","delay-in-days":5512,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Internal Medicine"],"published-print":{"date-parts":[[1994,7]]},"abstract":"<jats:p><jats:bold>Abstract. <\/jats:bold> <jats:bold>Objectives<\/jats:bold>. To compare intrabrachial blood pressure (I\u2010BP) with simultaneously measured contralateral auscultatory (A\u2010)BP in hypertensive and normotensive subjects. The question was whether differences between direct and indirect BP are influenced by the BP levels.<\/jats:p><jats:p><jats:bold>Subjects<\/jats:bold>. Hypertensive subjects treated with either placebo (<jats:italic>n<\/jats:italic> = 10) or metoprolol (<jats:italic>n<\/jats:italic> = 8) and agematched normotensive subjects (<jats:italic>n<\/jats:italic> = 15), selected from a defined patient population waiting for cholecystectomy or hernia repair. Measurements were performed pre\u2010induction of anaesthesia.<\/jats:p><jats:p><jats:bold>Results<\/jats:bold>. In the hypertensive subjects, cuff systolic BP (SBP) was lower than I\u2010BP by an average of 8 mmHg (placebo\u2010) and 7 mmHg (metoprolol\u2010treated), where\u2010as diastolic A\u2010BP (A\u2010DBP) was 3 and 7 mmHg higher, respectively. In the normotensive subjects, mean A\u2010SBP and I\u2010SBP agreed closely, whereas A\u2010DBP was 11 mmHg higher. Thus, SBP differences (i.e. indirect\u2013direct BP) were significantly less and DBP differences significantly greater in the normotensive than in the hypertensive subjects (<jats:italic>P<\/jats:italic> &lt; 0.05). Plasma renin activity and adrenalin showed better correlations with A\u2010MBP than with I\u2010MBP.<\/jats:p><jats:p><jats:bold>Conclusions<\/jats:bold>. The drift of cuff systolic readings fell progressively below the intrabrachial values when BP increased, whilst diastolic cuff values approached the direct pressures. Since A\u2010MBP did not significantly differ from I\u2010MBP in any group, one must ask whether hypertension would be more correctly defined according to MBP criteria.<\/jats:p>","DOI":"10.1111\/j.1365-2796.1994.tb01124.x","type":"journal-article","created":{"date-parts":[[2009,8,3]],"date-time":"2009-08-03T14:15:58Z","timestamp":1249308958000},"page":"85-90","source":"Crossref","is-referenced-by-count":14,"title":["Direct and indirect blood pressure in normotensive and hypertensive subjects"],"prefix":"10.1111","volume":"236","author":[{"given":"B.","family":"FAGHER","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"MAGN\u00daSSON","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"THULIN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2009,8,3]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.10.4.481"},{"key":"e_1_2_1_3_2","first-page":"11","article-title":"Comparison of direct and indirect methods of measuring arterial blood pressure","volume":"15","author":"Bruner JMR","year":"1981","journal-title":"Med Instrument"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1159\/000167089"},{"key":"e_1_2_1_5_2","first-page":"127","article-title":"Comparison of indirect pressure measurements (Korotkoff) with simultaneous direct brachial artery pressure distal to the cuff","volume":"13","author":"London SB","year":"1967","journal-title":"Adv Int Med"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1093\/cvr\/2.2.210"},{"key":"e_1_2_1_7_2","first-page":"297","article-title":"Controlled study of brachial artery blood pressure measured by a new indirect method","volume":"5","author":"Sheppard LC","year":"1971","journal-title":"Med Instrument"},{"key":"e_1_2_1_8_2","first-page":"285","article-title":"An examination of the differences that occur between direct and indirect blood pressure measurement","volume":"16","author":"Rebenson\u2010Piano M","year":"1987","journal-title":"Heart and Lung"},{"key":"e_1_2_1_9_2","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1093\/oxfordjournals.intqhc.a036720","article-title":"Is blood pressure measurement with a standard cuff reliable?","volume":"4","author":"Stolt M","year":"1992","journal-title":"Qual Assur Health Care"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.HYP.20.1.26"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/58.3.251"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1093\/clinchem\/22.2.250"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/0024-3205(77)90070-4"},{"key":"e_1_2_1_14_2","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1093\/clinchem\/27.2.341a","article-title":"Aluminium foil instead of glass plates for thin\u2010layer chromatography in radioenzymic assay","volume":"27","author":"Erikson B\u2010M.","year":"1981","journal-title":"Clin Chem"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.2.5419.1241"},{"key":"e_1_2_1_16_2","doi-asserted-by":"crossref","first-page":"1215","DOI":"10.1001\/jama.1973.03220380037008","article-title":"Sphygmomanometric cuff size and blood pressure recordings","volume":"225","author":"Burch GE","year":"1973","journal-title":"JAMA"},{"issue":"1","key":"e_1_2_1_17_2","first-page":"47","article-title":"Systolic blood pressure: arterial compliance and early wave reflection, and their modification by antihypertensive therapy","volume":"3","author":"O'Rourke M.","year":"1989","journal-title":"J Human Hypertension"},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.RES.4.1.4"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.RES.23.4.567"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.3949\/ccjm.55.5.448"},{"key":"e_1_2_1_21_2","first-page":"838","article-title":"Intraluminal pressures recorded simultaneously from different arteries in man (Abstract)","volume":"167","author":"Wood EH","year":"1951","journal-title":"Am J Physiol"},{"key":"e_1_2_1_22_2","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1016\/S0022-5223(19)39326-2","article-title":"Halothane and morphine\u2010nitrous oxide anesthesia in patients undergoing coronary artery bypass operation. Patterns of intraoperative ischemia","volume":"82","author":"Wilkinson PL","year":"1981","journal-title":"J Thorac Cardiovasc Surg"},{"key":"e_1_2_1_23_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03011476"},{"key":"e_1_2_1_24_2","doi-asserted-by":"publisher","DOI":"10.3949\/ccjm.55.5.415"},{"issue":"4","key":"e_1_2_1_25_2","first-page":"S96","article-title":"Simultaneous measurements of direct and indirect BP in patients who do not reach normotension during therapy. 14th Meeting of The International Society of Hypertension (Madrid) 1992","volume":"10","author":"Thulin T","year":"1992","journal-title":"J Hypertension"},{"key":"e_1_2_1_26_2","first-page":"553","article-title":"Felaktiga slutsatser om blodtryck m\u00e5tt intraarteriellt och med standardmanschett","volume":"87","author":"Schwan \u00c5.","year":"1990","journal-title":"L\u00e4kartidningen"},{"key":"e_1_2_1_27_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.295.6594.354"},{"issue":"1","key":"e_1_2_1_28_2","first-page":"53","article-title":"Arterial compliance in hypertension","volume":"3","author":"London GM","year":"1989","journal-title":"J Human Hypertension"},{"key":"e_1_2_1_29_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2125.1982.tb01946.x"}],"container-title":["Journal of Internal Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2796.1994.tb01124.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1365-2796.1994.tb01124.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,24]],"date-time":"2023-10-24T16:52:42Z","timestamp":1698166362000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1365-2796.1994.tb01124.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1994,7]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[1994,7]]}},"alternative-id":["10.1111\/j.1365-2796.1994.tb01124.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1365-2796.1994.tb01124.x","archive":["Portico"],"relation":{},"ISSN":["0954-6820","1365-2796"],"issn-type":[{"value":"0954-6820","type":"print"},{"value":"1365-2796","type":"electronic"}],"subject":[],"published":{"date-parts":[[1994,7]]}}}