{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,28]],"date-time":"2026-01-28T05:13:51Z","timestamp":1769577231575,"version":"3.49.0"},"reference-count":17,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2007,10,1]],"date-time":"2007-10-01T00:00:00Z","timestamp":1191196800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal of Microscopy"],"published-print":{"date-parts":[[2007,10]]},"abstract":"<jats:title>Summary<\/jats:title><jats:p> <jats:italic>Objectives:<\/jats:italic> The goal of this study was to examine the feasibility of <jats:italic>in vivo<\/jats:italic> imaging of trabecular bone around titanium implants by means of microfocus computed tomography (micro\u2010CT) and the use of rabbits for this purpose.<\/jats:p><jats:p> <jats:italic>Materials and Methods:<\/jats:italic> Ten male rabbits type Hollander, received a titanium implant (1.7 mm diameter and 10 mm length) in the trabecular bone of the left tibia. Seven weeks later a micro\u2010CT scan was taken. Four rabbits were used to monitor potential harmful effects from X\u2010ray absorption until 4 weeks after scanning. A second group of six rabbits was used for testing the hypothesis that a good correlation exists between <jats:italic>in vivo<\/jats:italic> micro\u2010CT images and histological images of trabecular bone around titanium implants. The six rabbits were scanned and sacrificed immediately. The tibias were extracted and submitted to standard histological procedures. This resulted in a total of 12 histological sections and their corresponding 12 micro\u2010CT images. Bone area measurements were performed at the left and right side of the implant in three regions: 0\u2013500, 500\u20131000 and 1000\u20131500 \u03bcm distance from the implant interface. Intra\u2010class correlations (ICC) were calculated between both techniques.<\/jats:p><jats:p> <jats:italic>Results:<\/jats:italic> The four rabbits did not show any sign of radiodermatitis 4 weeks after scanning. In the micro\u2010CT images of the group of six rabbits, trabeculae are visible, but not well defined, due to the presence of noise in the image. The ICC for the right implant side were 0.44 for zone 0\u2013500 \u03bcm, 0.48 for zone 500\u20131000 \u03bcm and 0.40 for zone 1000\u20131500 \u03bcm. The ICC for the left implant side could not be calculated.<\/jats:p><jats:p> <jats:italic>Conclusion:<\/jats:italic> A low agreement was found between the bone measurements from histology and <jats:italic>in vivo<\/jats:italic> micro\u2010CT images. The use of the <jats:italic>in vivo<\/jats:italic> micro\u2010CT for trabecular bone imaging around metallic implants should be restricted to track tendencies in follow\u2010up studies.<\/jats:p>","DOI":"10.1111\/j.1365-2818.2007.01823.x","type":"journal-article","created":{"date-parts":[[2007,10,3]],"date-time":"2007-10-03T07:09:51Z","timestamp":1191395391000},"page":"55-61","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Feasibility of detecting trabecular bone around percutaneous titanium implants in rabbits by <i>in vivo<\/i> microfocus computed tomography"],"prefix":"10.1111","volume":"228","author":[{"given":"NELE","family":"STOPPIE","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MARTINE","family":"WEVERS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"IGNACE","family":"NAERT","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2007,10]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1177\/00220345970760020601"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0722.2006.00355.x"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.1.000612"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbmr.5650040103"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.1617353"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.3109\/02844318509074508"},{"key":"e_1_2_7_8_1","first-page":"546","article-title":"The guinea pig as an animal model for the study of immediately loaded implants: a feasibility study","volume":"24","author":"Jaecques S.V.N.","year":"2001","journal-title":"Int. J. Artif. Organs"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(03)00516-7"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbmr.5650100213"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100080608"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1269\/jrr.47.9"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.3109\/02841869309083889"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02509542"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2005.tb00051.x"},{"key":"e_1_2_7_16_1","first-page":"85","volume-title":"X\u2010ray confirmed tomography. Fundamentals of Medical Imaging","author":"Suetens P.","year":"2002"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1563\/1548-1336(2000)026<0005:TUOMCT>2.3.CO;2"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bone.2003.08.012"}],"container-title":["Journal of Microscopy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2818.2007.01823.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1365-2818.2007.01823.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,12]],"date-time":"2023-10-12T12:51:20Z","timestamp":1697115080000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1365-2818.2007.01823.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,10]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2007,10]]}},"alternative-id":["10.1111\/j.1365-2818.2007.01823.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1365-2818.2007.01823.x","archive":["Portico"],"relation":{},"ISSN":["0022-2720","1365-2818"],"issn-type":[{"value":"0022-2720","type":"print"},{"value":"1365-2818","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,10]]},"assertion":[{"value":"2007-10-01","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}