{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,17]],"date-time":"2026-02-17T11:29:35Z","timestamp":1771327775378,"version":"3.50.1"},"reference-count":31,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2008,3,5]],"date-time":"2008-03-05T00:00:00Z","timestamp":1204675200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J of Oral Rehabilitation"],"published-print":{"date-parts":[[2008,4]]},"abstract":"<jats:p><jats:bold><jats:sc>summary<\/jats:sc>\u2002<\/jats:bold> This study investigated the effects of the stiffness of a maxillary sinus graft and the surface roughness of an immediately loaded implant using a non\u2010linear three\u2010dimensional finite element (FE) analysis (3D). Six FE models were created, including two stiffness values of grafted bone (345 and 3450\u2003MPa of elastic modulus) and three conditions of implant\u2013bone interfaces (Frictional coefficient of 0\u00b73 for machined surface, 0\u00b745 for rough implant surface and a bonded implant\u2013bone interface for an osseointegrated implant). Computer tomographic images of a human skull were used to construct a posterior maxillary model. All implants were designed via the computer aided design software with a spiral threaded configuration. Three loading scenarios were investigated for each of the six models; axial loading and lateral loadings at 30\u00b0 and 60\u00b0. The results showed that a 60\u00b0 lateral loading has scored the highest level of bone stresses among the three loading conditions. Immediately loaded implants with 0\u00b73 frictional coefficient have suffered the highest bone stresses which were higher than those with bonded interface by about 57%. Increasing the frictional coeffecient to 0\u00b745, however, did not show any benefits in reducing the peak bone stress. Raising the stiffness of grafted bone diminished the bone stress by about 10% in both the immediately loaded and the osseointegrated implants. It was also noted that increasing graft stiffness and implant surface roughness reduced the sliding at the implant\u2010bone interface which may improve the implant stability and long\u2010term survival.<\/jats:p>","DOI":"10.1111\/j.1365-2842.2007.01817.x","type":"journal-article","created":{"date-parts":[[2008,3,6]],"date-time":"2008-03-06T00:18:43Z","timestamp":1204762723000},"page":"283-290","source":"Crossref","is-referenced-by-count":21,"title":["Effects of implant surface roughness and stiffness of grafted bone on an immediately loaded maxillary implant: a 3D numerical analysis"],"prefix":"10.1111","volume":"35","author":[{"given":"H.\u2010L.","family":"HUANG","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L.\u2010J.","family":"FUH","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.\u2010T.","family":"HSU","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.\u2010G.","family":"TU","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Y.\u2010W.","family":"SHEN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.\u2010L.","family":"WU","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2008,3,5]]},"reference":[{"key":"e_1_2_8_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/0278-2391(86)90078-9"},{"key":"e_1_2_8_3_2","doi-asserted-by":"publisher","DOI":"10.1563\/0722.1"},{"key":"e_1_2_8_4_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.2003.00950.x"},{"key":"e_1_2_8_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2001.tb00142.x"},{"key":"e_1_2_8_6_2","first-page":"55","article-title":"Sinus augmentation for single\u2010tooth replacement in the posterior maxilla: a 3\u2010year follow\u2010up clinical report","volume":"14","author":"Mazor Z","year":"1999","journal-title":"Int J Oral Maxillofac Surg"},{"key":"e_1_2_8_7_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.2001.012003279.x"},{"key":"e_1_2_8_8_2","first-page":"143","article-title":"Immediate loading in oral implants. Present situation","volume":"10","author":"Uribe R","year":"2005","journal-title":"Med Oral Patol Oral Cir Bucal"},{"key":"e_1_2_8_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1079-2104(98)90391-2"},{"key":"e_1_2_8_10_2","first-page":"758","article-title":"Two\u2010stage maxillary sinus reconstruction with endosseous implants: a prospective study","volume":"13","author":"Blomqvist JE","year":"1998","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_8_11_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.1997.080302.x"},{"key":"e_1_2_8_12_2","first-page":"675","article-title":"Implant Materials, designs, and surface topographies: their effect on osseointegration. A literature review","volume":"15","author":"Sykaras R","year":"2000","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_8_13_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820241107"},{"key":"e_1_2_8_14_2","doi-asserted-by":"publisher","DOI":"10.1002\/nme.1620350609"},{"key":"e_1_2_8_15_2","first-page":"20","article-title":"Measurement of masticatory forces and implant loads: a methodologic clinical study","volume":"15","author":"Morneburg TR","year":"2002","journal-title":"Int J Prosthodont"},{"key":"e_1_2_8_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2005.01124.x"},{"key":"e_1_2_8_17_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0722.2004.00143.x"},{"key":"e_1_2_8_18_2","doi-asserted-by":"publisher","DOI":"10.1563\/0.674.1"},{"key":"e_1_2_8_19_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.2002.130613.x"},{"key":"e_1_2_8_20_2","doi-asserted-by":"publisher","DOI":"10.1067\/mpr.2001.115251"},{"key":"e_1_2_8_21_2","first-page":"326","article-title":"Bending overload and implant fracture: a retrospective clinical analysis","volume":"10","author":"Rangert B","year":"1995","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_8_22_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.1996.090606.x"},{"key":"e_1_2_8_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-198607000-00023"},{"key":"e_1_2_8_24_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2003.tb00199.x"},{"key":"e_1_2_8_25_2","doi-asserted-by":"publisher","DOI":"10.1902\/annals.2003.8.1.328"},{"key":"e_1_2_8_26_2","first-page":"565","article-title":"Systematic review of survival rates for implants placed in the grafted maxillary sinus","volume":"24","author":"Del Fabbro M","year":"2004","journal-title":"Int J Periodontics Restorative Dent"},{"key":"e_1_2_8_27_2","first-page":"667","article-title":"Load transfer by an implant in a sinus\u2010grafted maxillary model","volume":"18","author":"Fanuscu MI","year":"2003","journal-title":"Int J Oral Maxillofac Implants"},{"key":"e_1_2_8_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.joms.2005.11.016"},{"key":"e_1_2_8_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0278-2391(99)90437-8"},{"key":"e_1_2_8_30_2","doi-asserted-by":"publisher","DOI":"10.1002\/ajpa.10121"},{"key":"e_1_2_8_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(02)00057-X"},{"key":"e_1_2_8_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(88)90219-9"}],"container-title":["Journal of Oral Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2842.2007.01817.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1365-2842.2007.01817.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,11]],"date-time":"2023-10-11T00:10:11Z","timestamp":1696983011000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1365-2842.2007.01817.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,3,5]]},"references-count":31,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2008,4]]}},"alternative-id":["10.1111\/j.1365-2842.2007.01817.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1365-2842.2007.01817.x","archive":["Portico"],"relation":{},"ISSN":["0305-182X","1365-2842"],"issn-type":[{"value":"0305-182X","type":"print"},{"value":"1365-2842","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,3,5]]}}}