{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T18:08:08Z","timestamp":1793383688471,"version":"4.5.0"},"reference-count":17,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2012,11,24]],"date-time":"2012-11-24T00:00:00Z","timestamp":1353715200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Sleep Research"],"published-print":{"date-parts":[[2013,4]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:p>\n                    Obstructive sleep apnoea is a highly prevalent but under\u2010diagnosed disorder. The gold standard for diagnosis of obstructive sleep apnoea is inpatient polysomnography. This is resource intensive and inconvenient for the patient, and the development of ambulatory diagnostic modalities has been identified as a key research priority.\n                    <jats:styled-content style=\"fixed-case\">S<\/jats:styled-content>\n                    leep\n                    <jats:styled-content style=\"fixed-case\">M<\/jats:styled-content>\n                    inder (\n                    <jats:styled-content style=\"fixed-case\">B<\/jats:styled-content>\n                    ianca\n                    <jats:styled-content style=\"fixed-case\">M<\/jats:styled-content>\n                    ed,\n                    <jats:styled-content style=\"fixed-case\">N<\/jats:styled-content>\n                    ova\n                    <jats:styled-content style=\"fixed-case\">UCD<\/jats:styled-content>\n                    ,\n                    <jats:styled-content style=\"fixed-case\">I<\/jats:styled-content>\n                    reland) is a novel, non\u2010contact, bedside sensor, which uses radio\u2010waves to measure respiration and movement. Previous studies have shown it to be effective in measuring sleep and respiration. We sought to assess its utility in the diagnosis of obstructive sleep apnoea.\n                    <jats:styled-content style=\"fixed-case\">S<\/jats:styled-content>\n                    leep\n                    <jats:styled-content style=\"fixed-case\">M<\/jats:styled-content>\n                    inder and polysomnographic assessment of sleep\u2010disordered breathing were performed simultaneously on consecutive subjects recruited prospectively from our sleep clinic. We assessed the diagnostic accuracy of\n                    <jats:styled-content style=\"fixed-case\">S<\/jats:styled-content>\n                    leep\n                    <jats:styled-content style=\"fixed-case\">M<\/jats:styled-content>\n                    inder in identifying obstructive sleep apnoea, and how\n                    <jats:styled-content style=\"fixed-case\">S<\/jats:styled-content>\n                    leep\n                    <jats:styled-content style=\"fixed-case\">M<\/jats:styled-content>\n                    inder assessment of the apnoea\u2013hypopnoea index correlated with polysomnography. Seventy\u2010four subjects were recruited. The apnoea\u2013hypopnoea index as measured by\n                    <jats:styled-content style=\"fixed-case\">S<\/jats:styled-content>\n                    leep\n                    <jats:styled-content style=\"fixed-case\">M<\/jats:styled-content>\n                    inder correlated strongly with polysomnographic measurement (\n                    <jats:italic>r\u00a0<\/jats:italic>\n                    =\u00a00.90;\n                    <jats:italic>P\u00a0<\/jats:italic>\n                    \u2264\u00a00.0001). When a diagnostic threshold of moderate\u2013severe (apnoea\u2013hypopnoea index\u00a0\u226515\u00a0events\u00a0h\n                    <jats:sup>\u22121<\/jats:sup>\n                    ) obstructive sleep apnoea was used,\n                    <jats:styled-content style=\"fixed-case\">S<\/jats:styled-content>\n                    leep\n                    <jats:styled-content style=\"fixed-case\">M<\/jats:styled-content>\n                    inder displayed a sensitivity of 90%, a specificity of 92% and an accuracy of 91% in the diagnosis of sleep\u2010disordered breathing. The area under the curve for the receiver operator characteristic was 0.97.\n                    <jats:styled-content style=\"fixed-case\">S<\/jats:styled-content>\n                    leep\n                    <jats:styled-content style=\"fixed-case\">M<\/jats:styled-content>\n                    inder correctly classified obstructive sleep apnoea severity in the majority of cases, with only one case different from equivalent polysomnography by more than one diagnostic class. We conclude that in an unselected clinical population undergoing investigation for suspected obstructive sleep apnoea,\n                    <jats:styled-content style=\"fixed-case\">S<\/jats:styled-content>\n                    leep\n                    <jats:styled-content style=\"fixed-case\">M<\/jats:styled-content>\n                    inder measurement of sleep\u2010disordered breathing correlates significantly with polysomnography.\n                  <\/jats:p>","DOI":"10.1111\/j.1365-2869.2012.01056.x","type":"journal-article","created":{"date-parts":[[2012,11,24]],"date-time":"2012-11-24T02:46:10Z","timestamp":1353725170000},"page":"231-236","source":"Crossref","is-referenced-by-count":58,"title":["Assessment of sleep\u2010disordered breathing using a non\u2010contact bio\u2010motion sensor"],"prefix":"10.1111","volume":"22","author":[{"given":"Alberto","family":"Zaffaroni","sequence":"first","affiliation":[{"name":"BiancaMed NovaUCD Dublin Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian","family":"Kent","sequence":"additional","affiliation":[{"name":"The Respiratory Sleep Disorders Unit St Vincent's University Healthcare Group Dublin Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emer","family":"O'Hare","sequence":"additional","affiliation":[{"name":"BiancaMed NovaUCD Dublin Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Conor","family":"Heneghan","sequence":"additional","affiliation":[{"name":"BiancaMed NovaUCD Dublin Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patricia","family":"Boyle","sequence":"additional","affiliation":[{"name":"The Respiratory Sleep Disorders Unit St Vincent's University Healthcare Group Dublin Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Geraldine","family":"O'Connell","sequence":"additional","affiliation":[{"name":"The Respiratory Sleep Disorders Unit St Vincent's University Healthcare Group Dublin Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Pallin","sequence":"additional","affiliation":[{"name":"The Respiratory Sleep Disorders Unit St Vincent's University Healthcare Group Dublin Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philip","family":"de Chazal","sequence":"additional","affiliation":[{"name":"BiancaMed NovaUCD Dublin Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Walter T.","family":"McNicholas","sequence":"additional","affiliation":[{"name":"The Respiratory Sleep Disorders Unit St Vincent's University Healthcare Group Dublin Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2012,11,24]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1093\/sleep\/22.5.667"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2869.2010.00876.x"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.5664\/jcsm.27032"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.127.6.2076"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.5664\/jcsm.26861"},{"key":"e_1_2_7_7_1","volume-title":"The AASM Manual for the Scoring of Sleep and Associated Events: Rules, Terminology and Technical Specifications","author":"Iber C.","year":"2007"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1513\/pats.2009-042WS"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1513\/pats.200708-118MG"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1183\/09031936.00027406"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1001\/archinte.163.5.565"},{"key":"e_1_2_7_12_1","first-page":"630","article-title":"Real time breathing rate estimation from a non contact biosensor","volume":"2010","author":"Shouldice R. B.","year":"2010","journal-title":"Conf. Proc. IEEE Eng. Med. Biol. Soc."},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.09-0577"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.5664\/jcsm.26292"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199304293281704"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.2109080"},{"key":"e_1_2_7_17_1","first-page":"7091","article-title":"SleepMinder: an innovative contact\u2010free device for the estimation of the apnoea\u2010hypopnoea index","volume":"2009","author":"Zaffaroni A.","year":"2009","journal-title":"Conf. Proc. IEEE Eng. Med. Biol. Soc."},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1093\/sleep\/29.3.367"}],"container-title":["Journal of Sleep Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2869.2012.01056.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1365-2869.2012.01056.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,22]],"date-time":"2023-11-22T11:39:08Z","timestamp":1700653148000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1365-2869.2012.01056.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,11,24]]},"references-count":17,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2013,4]]}},"alternative-id":["10.1111\/j.1365-2869.2012.01056.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1365-2869.2012.01056.x","archive":["Portico"],"relation":{},"ISSN":["0962-1105","1365-2869"],"issn-type":[{"value":"0962-1105","type":"print"},{"value":"1365-2869","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,11,24]]}}}