{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T16:52:23Z","timestamp":1788540743350,"version":"build-2803163510"},"reference-count":6,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2010,12,2]],"date-time":"2010-12-02T00:00:00Z","timestamp":1291248000000},"content-version":"vor","delay-in-days":31,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clinical Transplantation"],"published-print":{"date-parts":[[2010,11]]},"abstract":"<jats:p>Nomura R, Ishizaki Y, Sugo H, Yoshimoto J, Imamura, H, Kawasaki S. Late\u2010onset venous outflow obstruction treated by placement of a Foley balloon catheter in living donor liver transplantation using a left lobe. \u2028Clin Transplant 2010: 24: 723\u2013725. \u00a9 2010 John Wiley &amp; Sons A\/S.<\/jats:p><jats:p><jats:bold>Abstract:\u2002<\/jats:bold> A 60\u2010yr\u2010old man having hepatitis C virus\u2010associated liver cirrhosis and hepatocellular carcinoma underwent living donor liver transplantation using a left liver graft. On post\u2010operative day 20, the patient developed a large amount of ascites and hypovolemic shock because of decreased venous return. Emergency laparotomy revealed that fixation of the round ligament to the abdominal wall was loose, and free movement of the graft into the right subphrenic space had caused twisting the hepatic vein. After upward traction of the round ligament, two Foley balloon catheters were inserted into the right subphrenic space to maintain the graft in the midline portion. The catheters with the balloons were removed on day 30 after re\u2010operation. This method is easy, simple and inexpensive for the treatment of hepatic venous outflow block after partial liver transplantation.<\/jats:p>","DOI":"10.1111\/j.1399-0012.2010.01227.x","type":"journal-article","created":{"date-parts":[[2010,2,23]],"date-time":"2010-02-23T02:58:28Z","timestamp":1266893908000},"page":"723-725","source":"Crossref","is-referenced-by-count":6,"title":["Late\u2010onset venous outflow obstruction treated by placement of a Foley balloon catheter in living donor liver transplantation using a left lobe"],"prefix":"10.1111","volume":"24","author":[{"given":"Ryohei","family":"Nomura","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoichi","family":"Ishizaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Sugo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiro","family":"Yoshimoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Imamura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seiji","family":"Kawasaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2010,12,2]]},"reference":[{"key":"e_1_2_4_2_2","first-page":"56","article-title":"Application of a tissue expander for stabilizing graft position in living\u2010related liver transplantation","volume":"11","author":"Inomata Y","year":"1997","journal-title":"Clin Transplant"},{"key":"e_1_2_4_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6060(97)90353-6"},{"key":"e_1_2_4_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.TP.0000131162.35391.9D"},{"key":"e_1_2_4_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-0012.2005.00431.x"},{"key":"e_1_2_4_6_2","doi-asserted-by":"publisher","DOI":"10.1002\/bjs.1800830814"},{"key":"e_1_2_4_7_2","doi-asserted-by":"publisher","DOI":"10.1002\/lt.500050604"}],"container-title":["Clinical Transplantation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1399-0012.2010.01227.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1399-0012.2010.01227.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,31]],"date-time":"2023-10-31T14:44:29Z","timestamp":1698763469000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1399-0012.2010.01227.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,11]]},"references-count":6,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2010,11]]}},"alternative-id":["10.1111\/j.1399-0012.2010.01227.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1399-0012.2010.01227.x","archive":["Portico"],"relation":{},"ISSN":["0902-0063","1399-0012"],"issn-type":[{"value":"0902-0063","type":"print"},{"value":"1399-0012","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,11]]}}}