{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T15:55:05Z","timestamp":1790870105148,"version":"4.1.0"},"reference-count":78,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2007,3,31]],"date-time":"2007-03-31T00:00:00Z","timestamp":1175299200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pediatric Transplantation"],"published-print":{"date-parts":[[2007,5]]},"abstract":"<jats:p><jats:bold>Abstract:\u2003\u2003<\/jats:bold> Mechanical circulatory support systems for the treatment of acute and chronic heart failure are now available for use in several clinical situations and are designed for different indications and support times. In children, particularly in small infants, extracorporeal membrane oxygenation and centrifugal pumps have been most widely used in the past. These systems are preferred for support after cardiac operations and for use in patients who have concomitant respiratory failure, but they are suitable for short\u2010term application only and intensive care is obligatory. VADs are designed for long\u2010term application and allow patients to be discharged home. Pneumatic pulsatile VADs have been available in pediatric sizes since 1992. Currently at our institution, 74 children have been supported with pediatric extracorporeal VADs for up to 14\u2003months. In the past five yr, a notable rise in survival has been achieved by improvements in pump design and pre\u2010 and post\u2010operative management. We have been able to discharge 78% of the infants under one yr old. In this review, our current VAD experience in children will be presented in the light of improvements in decision\u2010making, device technology, and implantation techniques, and in coagulation monitoring and anticoagulation. Additionally, new developments in the field of pediatric assist devices will be presented.<\/jats:p>","DOI":"10.1111\/j.1399-3046.2006.00611.x","type":"journal-article","created":{"date-parts":[[2007,4,20]],"date-time":"2007-04-20T19:24:11Z","timestamp":1177097051000},"page":"241-255","source":"Crossref","is-referenced-by-count":73,"title":["Ventricular assist devices in children: Current achievements and future perspectives"],"prefix":"10.1111","volume":"11","author":[{"given":"Evgenij V.","family":"Potapov","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brigitte","family":"Stiller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roland","family":"Hetzer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2007,3,31]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1177\/000313480006600918","article-title":"Extracorporeal membrane oxygenation for cardiac support in pediatric patients","volume":"66","author":"Mehta U","year":"2000","journal-title":"Am Surg"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/0003-4975(93)90529-Q"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(01)03209-X"},{"key":"e_1_2_7_5_2","first-page":"80","article-title":"Extracorporeal membrane oxygenation (ECMO) cardiopulmonary support in infancy","volume":"22","author":"Bartlett RH","year":"1976","journal-title":"Trans Am Soc Artif Intern Organs"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.MAT.0000151922.67540.E9"},{"key":"e_1_2_7_7_2","first-page":"II66","article-title":"Extracorporeal membrane oxygenation support as a bridge to pediatric heart transplantation","volume":"90","author":"Del Nido PJ","year":"1994","journal-title":"Circulation"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.1996.tb04513.x"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.pcsu.2006.02.003"},{"key":"e_1_2_7_10_2","first-page":"46","article-title":"Use of a left ventricular assist device as a bridge to transplantation in a pediatric patient","volume":"16","author":"Frazier OH","year":"1989","journal-title":"Tex Heart Inst J"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.1990.tb02985.x"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5223(20)31437-9"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa012175"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(99)00542-1"},{"key":"e_1_2_7_15_2","first-page":"S175","article-title":"Mechanical circulatory support and heart transplantation","volume":"11","author":"Hetzer R","year":"1992","journal-title":"J Heart Lung Transplant"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2005.07.002"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejheart.2006.02.003"},{"key":"e_1_2_7_18_2","doi-asserted-by":"crossref","first-page":"I37","DOI":"10.1161\/CIRCULATIONAHA.104.525352","article-title":"Long\u2010term results in patients with idiopathic dilated cardiomyopathy after weaning from left ventricular assist devices","volume":"112","author":"Dandel M","year":"2005","journal-title":"Circulation"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.mat.0000178967.97093.47"},{"key":"e_1_2_7_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2006.03.065"},{"key":"e_1_2_7_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/1010-7940(91)90045-L"},{"key":"e_1_2_7_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(97)00063-5"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpedsurg.2005.03.026"},{"key":"e_1_2_7_24_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.semperi.2005.02.005"},{"key":"e_1_2_7_25_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002480-200211000-00007"},{"key":"e_1_2_7_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1010-7940(97)00310-2"},{"key":"e_1_2_7_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(01)03027-2"},{"key":"e_1_2_7_28_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002480-200209000-00002"},{"key":"e_1_2_7_29_2","first-page":"157","volume-title":"Pediatr Card Surg Annu","author":"Hetzer R","year":"1999"},{"key":"e_1_2_7_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(97)00067-2"},{"key":"e_1_2_7_31_2","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1051\/ject\/2003352115","article-title":"Pulsatile mechanical cardiac assistance in pediatric patients with the Berlin heart ventricular assist device","volume":"35","author":"Merkle F","year":"2003","journal-title":"J Extra Corpor Technol"},{"key":"e_1_2_7_32_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.pcsu.2006.02.012"},{"key":"e_1_2_7_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2005.07.003"},{"key":"e_1_2_7_34_2","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1177\/039139889702001207","article-title":"Medos\/HIA\u2010assist system: First experiences with mechanical circulatory assist in infants and children","volume":"20","author":"Herwig V","year":"1997","journal-title":"Int J Artif Organs"},{"key":"e_1_2_7_35_2","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1051\/ject\/2004362158","article-title":"The combined use of extracorporeal life support and the Berlin Heart pulsatile pediatric ventricular assist device as a bridge to transplant in a toddler","volume":"36","author":"Laliberte E","year":"2004","journal-title":"J Extra Corpor Technol"},{"key":"e_1_2_7_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2005.04.023"},{"key":"e_1_2_7_37_2","doi-asserted-by":"publisher","DOI":"10.1038\/ncpcardio0575"},{"key":"e_1_2_7_38_2","first-page":"56","article-title":"Improving the antithrombogenity of artificial surfaces through heparin coating \u2013 Clinical experience with the pneumatic extracorporeal Berlin Heart assist device","volume":"4","author":"Kaufmann F","year":"1997","journal-title":"J An\u00e4sthesie Intensivbehandlung"},{"key":"e_1_2_7_39_2","doi-asserted-by":"publisher","DOI":"10.1067\/mtc.2001.111655"},{"key":"e_1_2_7_40_2","first-page":"24","article-title":"Surface modification with functionally active heparin. Heparin antibodies and thromboembolism in heparin\u2010coated and noncoated ventricular assist devices","volume":"6","author":"Riesenfeld J","year":"1995","journal-title":"Med Device Technol"},{"key":"e_1_2_7_41_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(02)04648-9"},{"key":"e_1_2_7_42_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-004-2352-z"},{"key":"e_1_2_7_43_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1053-2498(02)01233-0"},{"key":"e_1_2_7_44_2","first-page":"409","article-title":"Mechanical circulatory support for adolescent patients: The Ottawa Heart Institute experience","volume":"19","author":"Hendry PJ","year":"2003","journal-title":"Can J Cardiol"},{"key":"e_1_2_7_45_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1053-2498(02)00448-5"},{"key":"e_1_2_7_46_2","volume-title":"Tubes, Pump and Fragile Hope Keep a Baby's Heart Beating","author":"Grady D","year":"2004"},{"key":"e_1_2_7_47_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(00)02268-2"},{"key":"e_1_2_7_48_2","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1177\/039139880302600504","article-title":"Recovery of organ dysfunction during bridging to heart transplantation in children and adolescents","volume":"26","author":"El\u2010Banayosy NR","year":"2003","journal-title":"Int J Artif Organs"},{"key":"e_1_2_7_49_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.healun.2004.12.117"},{"key":"e_1_2_7_50_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2004.07378.x"},{"key":"e_1_2_7_51_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2006.03.065"},{"key":"e_1_2_7_52_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.105.577601"},{"key":"e_1_2_7_53_2","doi-asserted-by":"crossref","first-page":"S77","DOI":"10.1016\/S1053-2498(99)00112-6","article-title":"Selection and management of ventricular assist device patients: The Muenster experience","volume":"19","author":"Deng MC","year":"2000","journal-title":"J Heart Lung Transplant"},{"key":"e_1_2_7_54_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.103.2.231"},{"key":"e_1_2_7_55_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1053-2498(00)00174-1"},{"key":"e_1_2_7_56_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1010-7940(97)01185-8"},{"key":"e_1_2_7_57_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(00)02627-8"},{"key":"e_1_2_7_58_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2005.01.050"},{"key":"e_1_2_7_59_2","doi-asserted-by":"publisher","DOI":"10.1067\/mtc.2001.116197"},{"key":"e_1_2_7_60_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2003.08.013"},{"key":"e_1_2_7_61_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002480-200005000-00022"},{"key":"e_1_2_7_62_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5223(96)70111-3"},{"key":"e_1_2_7_63_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-1010235"},{"key":"e_1_2_7_64_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1053-2498(02)00488-6"},{"key":"e_1_2_7_65_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000129233.51320.92"},{"key":"e_1_2_7_66_2","doi-asserted-by":"publisher","DOI":"10.1097\/00001573-200403000-00015"},{"key":"e_1_2_7_67_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.mat.0000178214.95010.c0"},{"key":"e_1_2_7_68_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.MAT.0000093965.33300.83"},{"key":"e_1_2_7_69_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1053-2498(99)00116-3"},{"key":"e_1_2_7_70_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(99)00246-5"},{"key":"e_1_2_7_71_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5223(00)70142-5"},{"issue":"3","key":"e_1_2_7_72_2","first-page":"III183","article-title":"Pulsatile flow in patients with a novel nonpulsatile implantable ventricular assist device","volume":"102","author":"Potapov EV","year":"2000","journal-title":"Circulation"},{"key":"e_1_2_7_73_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2005.12.013"},{"key":"e_1_2_7_74_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2004.02.038"},{"key":"e_1_2_7_75_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.TP.0000137790.63159.48"},{"key":"e_1_2_7_76_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2005.04.018"},{"key":"e_1_2_7_77_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.pcsu.2006.02.016"},{"key":"e_1_2_7_78_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.105.571422"},{"key":"e_1_2_7_79_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.82.2.237"}],"container-title":["Pediatric Transplantation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1399-3046.2006.00611.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1399-3046.2006.00611.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T02:22:27Z","timestamp":1696904547000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1399-3046.2006.00611.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,3,31]]},"references-count":78,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2007,5]]}},"alternative-id":["10.1111\/j.1399-3046.2006.00611.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1399-3046.2006.00611.x","archive":["Portico"],"relation":{},"ISSN":["1397-3142","1399-3046"],"issn-type":[{"value":"1397-3142","type":"print"},{"value":"1399-3046","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,3,31]]}}}