{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,11,11]],"date-time":"2023-11-11T05:03:07Z","timestamp":1699678987612},"reference-count":22,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2008,12,30]],"date-time":"2008-12-30T00:00:00Z","timestamp":1230595200000},"content-version":"vor","delay-in-days":9891,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Anaesthesiol Scand"],"published-print":{"date-parts":[[1981,12]]},"abstract":"<jats:p>Haemodynamic responses to 50% nitrous oxide in oxygen during coronary artery surgery were investigated in 10 patients. Morphine, diazepam and pancuronium were given intravenously as both induction and maintenance anaesthesia. A significant decrease was seen in heart rate, arterial pressure, pulmonary artery pressure, heart rale\u2010systolic arterial pressure product, peripheral vascular resistance, left ventricular end\u2010diastolic pressure, dP\/dT of the left ventricle and resistance as measured in the graft to the left anterior descending coronary artery (LAD). No variations occurred in cardiac output, stroke volume, flow in the LAD\u2010graft, pulmonary artery pressure or heart rate\u2010systolic pulmonary artery pressure product or in dP\/dT of the right ventricle. Pulmonary vascular resistance increased. It was concluded that left ventricular performance did not decrease and that no deterioration of the oxygenation to the myocardium seemed to occur.<\/jats:p>","DOI":"10.1111\/j.1399-6576.1981.tb01700.x","type":"journal-article","created":{"date-parts":[[2009,1,1]],"date-time":"2009-01-01T10:07:17Z","timestamp":1230804437000},"page":"533-537","source":"Crossref","is-referenced-by-count":6,"title":["Haemodynamic Changes with the Administration of Nitrous Oxide During Coronary Artery Surgery"],"prefix":"10.1111","volume":"25","author":[{"given":"P.","family":"Lilleaasen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Semb","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Lindberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.","family":"Hatteland","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Ottesen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Simonsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2008,12,30]]},"reference":[{"key":"e_1_2_1_2_1","doi-asserted-by":"publisher","DOI":"10.1213\/00000539-198004000-00001"},{"key":"e_1_2_1_3_1","first-page":"533","volume-title":"The cardiovascular system","author":"Braunwald E.","year":"1979"},{"key":"e_1_2_1_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.1976.tb05028.x"},{"key":"e_1_2_1_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-197601000-00003"},{"key":"e_1_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1213\/00000539-197211000-00033"},{"key":"e_1_2_1_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.1980.tb01509.x"},{"key":"e_1_2_1_8_1","first-page":"61","article-title":"Direci myocardial effects of nitrous oxide","volume":"43","author":"Goldberg A. H.","year":"1972","journal-title":"Anesthesiology"},{"key":"e_1_2_1_9_1","doi-asserted-by":"publisher","DOI":"10.1213\/00000539-198002000-00003"},{"key":"e_1_2_1_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-197507000-00011"},{"key":"e_1_2_1_11_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM196912182812503"},{"key":"e_1_2_1_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF03005531"},{"key":"e_1_2_1_13_1","doi-asserted-by":"publisher","DOI":"10.1213\/00000539-198006000-00010"},{"key":"e_1_2_1_14_1","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-197407000-00025"},{"key":"e_1_2_1_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-198012000-00001"},{"key":"e_1_2_1_16_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.53.2.293"},{"key":"e_1_2_1_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(68)90117-3"},{"key":"e_1_2_1_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-197603000-00019"},{"key":"e_1_2_1_19_1","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-197301000-00012"},{"key":"e_1_2_1_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1973.tb00513.x"},{"issue":"1","key":"e_1_2_1_21_1","first-page":"171","article-title":"Rate\u2010pressure product and myocardial oxygen consumption during surgery for coronary artery bypass.","volume":"60","author":"Wilkinson P. L.","year":"1979","journal-title":"Circulation"},{"key":"e_1_2_1_22_1","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-197306000-00007"},{"key":"e_1_2_1_23_1","doi-asserted-by":"publisher","DOI":"10.1172\/JCI107869"}],"container-title":["Acta Anaesthesiologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1399-6576.1981.tb01700.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1399-6576.1981.tb01700.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,11]],"date-time":"2023-11-11T01:11:40Z","timestamp":1699665100000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1399-6576.1981.tb01700.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1981,12]]},"references-count":22,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1981,12]]}},"alternative-id":["10.1111\/j.1399-6576.1981.tb01700.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1399-6576.1981.tb01700.x","archive":["Portico"],"relation":{},"ISSN":["0001-5172","1399-6576"],"issn-type":[{"value":"0001-5172","type":"print"},{"value":"1399-6576","type":"electronic"}],"subject":[],"published":{"date-parts":[[1981,12]]}}}