{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,8]],"date-time":"2026-05-08T22:30:04Z","timestamp":1778279404171,"version":"3.51.4"},"reference-count":26,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2008,12,30]],"date-time":"2008-12-30T00:00:00Z","timestamp":1230595200000},"content-version":"vor","delay-in-days":8733,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Anaesthesiol Scand"],"published-print":{"date-parts":[[1985,2]]},"abstract":"<jats:p>Our objective was to investigate experimentally the easily overlooked effect of the clinical use of colloidal plasma substitutes on tissue perfusion. The experimental animals were dogs, and the study was carried out using several independent rheological experimental methods. The following are the principal findings: 1) Based on the observations made under a microscope, the stability of blood suspensions was best maintained by dextran\u201040 (Dex 40) and hydroxyethyl starch (HES<jats:sub>0.55<\/jats:sub>; Hespander\u00ae), both of which cause little rouleaux formation by erythrocytes. In addition, the electronegativity of the erythrocyte membrane was simultaneously elevated. 2) The blood viscosity was greatly affected by the hematocrit and the serum protein concentration. 3) At a high shear rate, the blood viscosity among these colloidal plasma substitutes showed no great difference after infusion; in contrast, at a low shear rate, the blood viscosity after infusion of Dex 40 or HES<jats:sub>0.55<\/jats:sub> was lower than after other substitutes. 4) The ratio of the viscosity at a low shear rate to the viscosity at a high shear rate is more significant and useful as a clinical indicator. On the basis of the preceding findings, Dex 40 and HES<jats:sub>0.55<\/jats:sub> were generally superior to the other substitutes, especially HES<jats:sub>0.55<\/jats:sub>.<\/jats:p>","DOI":"10.1111\/j.1399-6576.1985.tb02189.x","type":"journal-article","created":{"date-parts":[[2009,1,1]],"date-time":"2009-01-01T11:00:36Z","timestamp":1230807636000},"page":"217-223","source":"Crossref","is-referenced-by-count":16,"title":["Hemorrheological Effects of Colloidal Plasma Substitutes Infusion A Comparative Study"],"prefix":"10.1111","volume":"29","author":[{"given":"Y.","family":"GOTO","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"SAKAKURA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"HATTA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Y.","family":"SUGIURA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"KATO","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2008,12,30]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1001\/jama.1967.03120050039007","article-title":"Treatment of massive hemorrhage with colloid and crystalloid solutions. Studies in dogs","volume":"199","author":"Takaori M","year":"1967","journal-title":"J Am Med Assoc"},{"key":"e_1_2_1_3_2","first-page":"1235","article-title":"A study of safer plasma substitutes","volume":"128","author":"Gollub S","year":"1969","journal-title":"Surg Gynecol"},{"key":"e_1_2_1_4_2","first-page":"453","article-title":"The effect of whole blood and plasma expanders on volume\u2010flow relationships in critically ill patients","volume":"137","author":"Shoemaker W C","year":"1973","journal-title":"Surg Gynecol Obstet"},{"key":"e_1_2_1_5_2","first-page":"294","article-title":"Rheomacrodex \u2010 a new dextran solution for rheological treatment of impaired capillary flow","volume":"122","author":"Gelin L E","year":"1961","journal-title":"Acta Chir Scand"},{"key":"e_1_2_1_6_2","first-page":"343","article-title":"Indications for the use of low viscous dextran in surgery","volume":"122","author":"Bergentz S E","year":"1961","journal-title":"Acta Chir Scand"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(63)92482-6"},{"key":"e_1_2_1_8_2","first-page":"1189","article-title":"Rheomacrodex in peripheral ischemia","author":"Rowley P H.","year":"1963","journal-title":"Lancet"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-196310000-00005"},{"key":"e_1_2_1_10_2","first-page":"253","article-title":"The rheological effects of plasma expanders upon red blood cells","volume":"18","author":"Goto Y","year":"1973","journal-title":"Nagoya Med J"},{"key":"e_1_2_1_11_2","first-page":"46","article-title":"Observation of the red blood cells by differential phase contrast microscopy","volume":"3","author":"Goto Y.","year":"1971","journal-title":"Cell"},{"key":"e_1_2_1_12_2","first-page":"125","article-title":"Electrophoresis of red blood cells using U\u2010tube method and influence of plasma substitutes","volume":"17","author":"Goto Y","year":"1974","journal-title":"Asian Med J"},{"key":"e_1_2_1_13_2","first-page":"1398","article-title":"Plasma volume expanders and blood typing","volume":"154","author":"Smith A.","year":"1954","journal-title":"J Am Med Assoc"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(54)90457-2"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(54)90533-4"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02469455"},{"key":"e_1_2_1_17_2","first-page":"302","volume-title":"Modified gelatins as plasma substitutes","author":"Ehrly A M.","year":"1969"},{"key":"e_1_2_1_18_2","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1016\/S0022-5223(19)32932-0","article-title":"Viscosity studies of blood, plasma, and plasma substitutes","volume":"44","author":"Reemtsma K","year":"1962","journal-title":"J Thorac Cardiovasc Surg"},{"key":"e_1_2_1_19_2","doi-asserted-by":"crossref","first-page":"171","DOI":"10.3233\/BIR-1971-83-408","article-title":"The viscosity of human blood plasma. Its measurement in health and disease","volume":"8","author":"Harkness J.","year":"1971","journal-title":"Biorheology"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1152\/physrev.1969.49.4.863"},{"key":"e_1_2_1_21_2","first-page":"342","article-title":"Blood viscosity in the normal man","volume":"67","author":"Litwin M S","year":"1970","journal-title":"Surgery"},{"key":"e_1_2_1_22_2","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1152\/jappl.1969.26.5.674","article-title":"Microscopy and viscometry of blood flowing under uniform shear rate (rheoscopy)","volume":"26","author":"Schmid\u2010Schoenbein J","year":"1969","journal-title":"J Appl Physiol"},{"key":"e_1_2_1_23_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1966.21.1.81"},{"key":"e_1_2_1_24_2","doi-asserted-by":"crossref","first-page":"35","DOI":"10.3233\/BIR-1971-8106","article-title":"Comparative hemorrheology\u2010hematological implications of species differences in blood viscosity","volume":"8","author":"Chien S","year":"1971","journal-title":"Biorheology"},{"key":"e_1_2_1_25_2","doi-asserted-by":"publisher","DOI":"10.3181\/00379727-131-34050"},{"key":"e_1_2_1_26_2","first-page":"298","volume-title":"Modified gelatins as plasma substitutes","author":"Barras J P.","year":"1969"},{"key":"e_1_2_1_27_2","doi-asserted-by":"publisher","DOI":"10.1136\/jcp.29.9.855"}],"container-title":["Acta Anaesthesiologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1399-6576.1985.tb02189.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1399-6576.1985.tb02189.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,21]],"date-time":"2023-10-21T12:28:38Z","timestamp":1697891318000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1399-6576.1985.tb02189.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1985,2]]},"references-count":26,"journal-issue":{"issue":"2","published-print":{"date-parts":[[1985,2]]}},"alternative-id":["10.1111\/j.1399-6576.1985.tb02189.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1399-6576.1985.tb02189.x","archive":["Portico"],"relation":{},"ISSN":["0001-5172","1399-6576"],"issn-type":[{"value":"0001-5172","type":"print"},{"value":"1399-6576","type":"electronic"}],"subject":[],"published":{"date-parts":[[1985,2]]}}}