{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,28]],"date-time":"2023-10-28T15:13:04Z","timestamp":1698505984494},"reference-count":6,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2008,12,30]],"date-time":"2008-12-30T00:00:00Z","timestamp":1230595200000},"content-version":"vor","delay-in-days":4992,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Anaesthesiol Scand"],"published-print":{"date-parts":[[1995,5]]},"abstract":"<jats:p>Standard methods for the assessment of the compliance of the respiratory system require recordings of both airway pressure and ventilatory volume. A method based on the recording of respiratory flow only, with no need of measuring airway pressure was reported some years ago. The purpose of the present study was to test a modification of this flow\u2010recording technique.<\/jats:p><jats:p>The technique is based on the measurement of inspiratory flow with and without the addition of a source of external compliance added to the inspiratory circuit. The difference in inspiratory flow between these two situations can be used to derive the compliance of the respiratory system. The method was tested in model experiments and in patients with acute respiratory failure, and compared with a standard method based on airway pressure and inspiratory gas flow recording.<\/jats:p><jats:p>Model experiments showed strong correlation between the new flow\u2010recording method and the standard method (r\u20140.99, <jats:italic>P<\/jats:italic> &lt;0.001) with a coefficient of variation of less than 2% with both methods. In patients with acute respiratory failure, the flow and standard methods gave similar results when no end\u2010inspiratory pause was applied (mean difference 5\u00b140 ml\/kPa (x\u00b1s.d.)). The standard method gave significandy higher compliance values, different from the flow method, when an end\u2010inspiratory pause of 10% was applied (mean difference 53 \u00b12 ml\/kPa, <jats:italic>P<\/jats:italic> &lt;0.01). The flow method was not influenced by the use of an end\u2010inspiratory pause. In conclusion, the flow method measures dynamic compliance and is not influenced by end\u2010inspiratory or end\u2010expiratory flow. It requires only a flow\u2010sensor for the measurement of relative values, reducing the need for calibration procedures. However, the flow method cannot replace conventional technique for assessment of static compliance.<\/jats:p>","DOI":"10.1111\/j.1399-6576.1995.tb04100.x","type":"journal-article","created":{"date-parts":[[2009,1,1]],"date-time":"2009-01-01T02:10:52Z","timestamp":1230775852000},"page":"462-466","source":"Crossref","is-referenced-by-count":2,"title":["Assessment of respiratory system compliance by a flow recording method"],"prefix":"10.1111","volume":"39","author":[{"given":"M.","family":"Darowski","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"I.","family":"Gottlieb\u2010Inacio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"U.","family":"Ludwigs","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Hedenstierna","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2008,12,30]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.73.2.158"},{"key":"e_1_2_1_3_2","first-page":"A333","article-title":"Online pulmonary resistance and elastance in pediatrics","volume":"55","author":"Goldman L.","year":"1981","journal-title":"Anesthesiol Pediatr Anesth"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF00265800"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.1985.tb02222.x"},{"key":"e_1_2_1_6_2","first-page":"729","article-title":"Monitoring of ventilation and lung mechanics during automatic ventilation","volume":"11","author":"Jonson B.","year":"1975","journal-title":"Bull Eur Physiopathol Respir"},{"key":"e_1_2_1_7_2","first-page":"672","article-title":"Measurement of static compliance of total respiratory system in patients with acute respiratory failure during mechanical ventilation","volume":"131","author":"Rossi A.","year":"1985","journal-title":"Am Res Respir Dis"}],"container-title":["Acta Anaesthesiologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1399-6576.1995.tb04100.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1399-6576.1995.tb04100.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,27]],"date-time":"2023-10-27T02:23:00Z","timestamp":1698373380000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1399-6576.1995.tb04100.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1995,5]]},"references-count":6,"journal-issue":{"issue":"4","published-print":{"date-parts":[[1995,5]]}},"alternative-id":["10.1111\/j.1399-6576.1995.tb04100.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1399-6576.1995.tb04100.x","archive":["Portico"],"relation":{},"ISSN":["0001-5172","1399-6576"],"issn-type":[{"value":"0001-5172","type":"print"},{"value":"1399-6576","type":"electronic"}],"subject":[],"published":{"date-parts":[[1995,5]]}}}