{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:26:45Z","timestamp":1760189205993},"reference-count":15,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2011,9,1]],"date-time":"2011-09-01T00:00:00Z","timestamp":1314835200000},"content-version":"vor","delay-in-days":6087,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Anaesthesiol Scand"],"published-print":{"date-parts":[[1995,1]]},"abstract":"<jats:p>Endotracheal intubation in infants with the Pierre Robin syndrome may sometimes be impossible to accomplish by conventional means. To aid difficult tracheal intubation many different techniques have been described.<\/jats:p><jats:p>We present a case, in which we successfully intubated a small\u2010for\u2010date newborn boy with the Pierre Robin syndrome by using a modified laryngeal mask airway (no. 1) as a guide for the endotracheal tube. The technique is easy to perform, less traumatic and less time\u2010consuming than multiple attempts at laryngoscopy or blind tracheal intubation.<\/jats:p>","DOI":"10.1111\/j.1399-6576.1995.tb05604.x","type":"journal-article","created":{"date-parts":[[2011,9,1]],"date-time":"2011-09-01T19:48:00Z","timestamp":1314906480000},"page":"129-131","source":"Crossref","is-referenced-by-count":43,"title":["Laryngeal mask airway guided tracheal intubation in a neonate with the Pierre Robin syndrome"],"prefix":"10.1111","volume":"39","author":[{"given":"Tom G.","family":"Hansen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Henning","family":"Joensen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Steen W.","family":"Henneberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Hole","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2011,9]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1177\/000348948309200423"},{"key":"e_1_2_1_3_2","first-page":"22","article-title":"Anesthetic management of patients with compromised airways","volume":"7","author":"Donlon J V.","year":"1980","journal-title":"Anesth Rev"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM197610142951607"},{"key":"e_1_2_1_5_2","first-page":"270","article-title":"Clinical experience with the Robin sequence","volume":"21","author":"Pashayan H M","year":"1984","journal-title":"Cleft Palate Journal"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1985.tb10789.x"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.bdj.4807140"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1990.tb14620.x"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1990.tb14449.x"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1991.tb09621.x"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1991.tb09652.x"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.1992.tb00211.x"},{"key":"e_1_2_1_13_2","first-page":"343","article-title":"Fibreoptic tracheal intubation through a modified laryngeal mask","volume":"2","author":"Goldie A S","year":"1992","journal-title":"Paediatr Anaesth"},{"key":"e_1_2_1_14_2","first-page":"344","article-title":"Laryngeal mask guided tracheal intubation in paediatric anaesthesia","volume":"2","author":"Dubreuil M.","year":"1992","journal-title":"Paediatr Anaesth"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/0952-8180(91)90205-2"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03008676"}],"container-title":["Acta Anaesthesiologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1399-6576.1995.tb05604.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1399-6576.1995.tb05604.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,25]],"date-time":"2023-10-25T19:42:18Z","timestamp":1698262938000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1399-6576.1995.tb05604.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1995,1]]},"references-count":15,"journal-issue":{"issue":"1","published-print":{"date-parts":[[1995,1]]}},"alternative-id":["10.1111\/j.1399-6576.1995.tb05604.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1399-6576.1995.tb05604.x","archive":["Portico"],"relation":{},"ISSN":["0001-5172","1399-6576"],"issn-type":[{"value":"0001-5172","type":"print"},{"value":"1399-6576","type":"electronic"}],"subject":[],"published":{"date-parts":[[1995,1]]}}}