{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:23:56Z","timestamp":1760189036562},"reference-count":10,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2008,12,30]],"date-time":"2008-12-30T00:00:00Z","timestamp":1230595200000},"content-version":"vor","delay-in-days":4565,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Anaesthesiol Scand"],"published-print":{"date-parts":[[1996,7]]},"abstract":"<jats:p><jats:bold>Background<\/jats:bold>: One\u2010lung ventilation in major thoracic surgery is the most commonly accepted technique, not only for surgery on the lung but also in procedures involving the oesophagus, mediastinum and thoracic aorta. Conventional double\u2010lumen tubes may sometimes be difficult to place correctly in patients in whom intubation is difficult. In such cases, the Univent System tube\u00ae may be of help. It has a curved movable blocker of small calibre, and is designed to slide inside the bronchial tree and occlude all or part of the target lung.<\/jats:p><jats:p><jats:bold>Case Report<\/jats:bold>: We describe a new application of the Univent System tube\u00ae in three cases where intubation was presumed to be difficult, and in another with unexpected difficult intubation.<\/jats:p><jats:p>The laryngeal approach was carried out with the distally displaced blocker, inserting it through the sub\u2010epiglottis or the posterior commissure visible orifice. The tube was firmly held and slid through the length of the blocker, rotating slowly until fully introduced. The advantages and criteria for its use are discussed.<\/jats:p><jats:p><jats:bold>Conclusion<\/jats:bold>: Although the double\u2010lumen tube is the first choice for one\u2010lung ventilation, the Univent tube is a good option for selective bronchial intubation and in patients in whom difficult intubation is predicted.<\/jats:p>","DOI":"10.1111\/j.1399-6576.1996.tb04526.x","type":"journal-article","created":{"date-parts":[[2009,1,1]],"date-time":"2009-01-01T01:07:18Z","timestamp":1230772038000},"page":"765-767","source":"Crossref","is-referenced-by-count":21,"title":["Use of the Univent System tube\u00ae for difficult intubation and for achieving one\u2010lung anaesthesia"],"prefix":"10.1111","volume":"40","author":[{"given":"R.","family":"Garc\u00edA\u2010Aguado","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E. M.","family":"Mateo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"V. J.","family":"Onrubia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Bolinches","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2008,12,30]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1986.tb13278.x"},{"key":"e_1_2_1_3_2","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1016\/S0022-5223(19)37196-X","article-title":"New device for one lung anaethesia: endotracheal tube with movable blocker","volume":"83","author":"Inoue H","year":"1982","journal-title":"J Thorac Cardiovasc Surg"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(10)61140-X"},{"key":"e_1_2_1_5_2","doi-asserted-by":"crossref","first-page":"1171","DOI":"10.1016\/S0022-5223(94)70410-4","article-title":"Univent endotracheal tube: twelve\u2010year experience","volume":"101","author":"Inoue H.","year":"1994","journal-title":"J Thorac Cardiovasc Surg"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1991.tb09909.x"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199312000-00058"},{"key":"e_1_2_1_8_2","first-page":"2387","volume-title":"Principles and practice of anesthesiology","author":"Parker SD.","year":"1993"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-198512000-00026"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/1053-0770(92)90201-H"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(10)63725-3"}],"container-title":["Acta Anaesthesiologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1399-6576.1996.tb04526.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1399-6576.1996.tb04526.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,27]],"date-time":"2023-10-27T19:11:08Z","timestamp":1698433868000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1399-6576.1996.tb04526.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1996,7]]},"references-count":10,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1996,7]]}},"alternative-id":["10.1111\/j.1399-6576.1996.tb04526.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1399-6576.1996.tb04526.x","archive":["Portico"],"relation":{},"ISSN":["0001-5172","1399-6576"],"issn-type":[{"value":"0001-5172","type":"print"},{"value":"1399-6576","type":"electronic"}],"subject":[],"published":{"date-parts":[[1996,7]]}}}