{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,5,12]],"date-time":"2024-05-12T17:17:57Z","timestamp":1715534277544},"reference-count":13,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2008,12,30]],"date-time":"2008-12-30T00:00:00Z","timestamp":1230595200000},"content-version":"vor","delay-in-days":4503,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Anaesthesiol Scand"],"published-print":{"date-parts":[[1996,9]]},"abstract":"<jats:p><jats:bold>Background:<\/jats:bold> If intravenous access cannot be accomplished during cardiopulmonary resuscitation in children, tracheal administration of 100 \u03bcg\/kg of adrenaline (ten times greater than the intravenous dose) is recommended.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> In a randomized crossover study we recorded the hemodynamic effect of a low dose of intravenous adrenaline and a ten times greater tracheal dose. While anesthetized for open heart surgery, fourteen infants received one dose of adrenaline intravenously (0.3 \u03bcg\/kg) and the other tracheally (3\u03bcg\/kg).<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> During the first 5 minutes after administration mean arterial pressure (MAP) and heart rate (HR) increased after both intravenous and tracheal administration (<jats:italic>P<\/jats:italic>&lt;0.001). The maximum increase in MAP was 28% (17\u201368%, median and range) after intravenous injection and 20% (6\u201369%, <jats:italic>P<\/jats:italic>&lt;0.05 when compared to intravenous injection) after tracheal instillation. In four infants, MAP increased less than 10% after tracheal instillation. The maximum increases in MAP and HR occurred 1 min (1\u20132 min) after intravenous injection and 3 min (2\u20134 min) after tracheal instillation (<jats:italic>P<\/jats:italic>&lt;0.001).<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> Tracheal administration of 3 \u03bcg\/kg adrenaline increased mean arterial blood pressure in infants with congenital cardiac anomalies, but the increase occurred later and was less consistent than after 0.3 \u03bcg\/kg of adrenaline given intravenously.<\/jats:p>","DOI":"10.1111\/j.1399-6576.1996.tb04562.x","type":"journal-article","created":{"date-parts":[[2009,1,1]],"date-time":"2009-01-01T02:23:53Z","timestamp":1230776633000},"page":"927-931","source":"Crossref","is-referenced-by-count":12,"title":["Hemodynamic effects of tracheal and intravenous adrenaline in infants with congenital heart anomalies"],"prefix":"10.1111","volume":"40","author":[{"given":"C.","family":"Jonmarker","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.\u2010K.","family":"Olsson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"J\u00f6gi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Forsell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2008,12,30]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.306.6892.1589"},{"key":"e_1_2_1_3_2","first-page":"2205","article-title":"Standards and guidelines for cardiopulmonary resuscitation and emergency cardiac care","volume":"268","author":"Emergency Cardiac Care Committee and Subcommittees, American Heart Association.","year":"1992","journal-title":"JAMA"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.308.6940.1349"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/0300-9572(90)90033-B"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(87)91608-4"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/0140-6736(92)93283-S"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/72.5.529"},{"key":"e_1_2_1_9_2","first-page":"172","article-title":"Pharmacotherapy of ventricular fibrillation. A prospective study in out\u2010of\u2010hospital resuscitation","volume":"40","author":"Sch\u00fcttler J","year":"1991","journal-title":"Anaesthesist"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1651-2227.1984.tb09930.x"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1136\/fn.70.3.F213"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0196-0644(85)80916-1"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0361-1124(79)80036-2"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199002000-00007"}],"container-title":["Acta Anaesthesiologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1399-6576.1996.tb04562.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1399-6576.1996.tb04562.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,27]],"date-time":"2023-10-27T05:32:27Z","timestamp":1698384747000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1399-6576.1996.tb04562.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1996,9]]},"references-count":13,"journal-issue":{"issue":"8","published-print":{"date-parts":[[1996,9]]}},"alternative-id":["10.1111\/j.1399-6576.1996.tb04562.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1399-6576.1996.tb04562.x","archive":["Portico"],"relation":{},"ISSN":["0001-5172","1399-6576"],"issn-type":[{"value":"0001-5172","type":"print"},{"value":"1399-6576","type":"electronic"}],"subject":[],"published":{"date-parts":[[1996,9]]}}}