{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T02:50:49Z","timestamp":1761706249611},"reference-count":32,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2008,12,31]],"date-time":"2008-12-31T00:00:00Z","timestamp":1230681600000},"content-version":"vor","delay-in-days":3744,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Anaesthesiol Scand"],"published-print":{"date-parts":[[1998,10]]},"abstract":"<jats:p><jats:bold>Background:<\/jats:bold> Artificial colloids affect haemostasis. Particularly hydroxyethyl starch (HES) solutions may have detrimental effects on haemostatic mechanisms.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> In a crossover study blood was withdrawn from ten volunteers. Ringer's acetate, 6% low molecular weight HES (M<jats:sub>w<\/jats:sub> 120 000\/molar substitution ratio 0.7), 10% low molecular weight HES M<jats:sub>w<\/jats:sub> 200 000\/0.5) and 6% high molecular weight HES (M<jats:sub>w<\/jats:sub> 400 000\/0.7) or 4% albumin was added to venous blood samples to make either 20 vol.% or 50 vol.% concentrations of each of the solutions. Samples were analyzed by thrombelastography (TEG).<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> All HES solutions at 20 vol.% concentration impaired haemostasis as demonstrated by decreased clot formation rate (\u03b1\u2010angle and maximum amplitude (MA)). In contrast, Ringer's acetate and albumin improved coagulability at 20 vol.% concentrations. Coagulation time (r+K) was prolonged at 50 vol.% dilutions of all solutions. The median r+K was greater with HES 400 (<jats:italic>P<\/jats:italic>&lt;0.05) and HES 200 (N. S.) than with HES 120.<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> We conclude that HES at 20 and 50 vol.% concentrations has an adverse effect on <jats:italic>in vitro<\/jats:italic> measures of coagulation. A 50% dilution with high molecular weight HES seems to impair coagulation more than low molecular weight HES. Ringer's acetate and albumin caused a hypercoagulable state at a concentration of 20 vol.%, but the higher concentration decreased coagulability.<\/jats:p>","DOI":"10.1111\/j.1399-6576.1998.tb05385.x","type":"journal-article","created":{"date-parts":[[2009,1,2]],"date-time":"2009-01-02T05:08:38Z","timestamp":1230872918000},"page":"1104-1109","source":"Crossref","is-referenced-by-count":42,"title":["Hydroxyethyl starch impairs <i>in vitro<\/i> coagulation"],"prefix":"10.1111","volume":"42","author":[{"given":"T. T.","family":"Niemi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A. H.","family":"Kuitunen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2008,12,31]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.1993.tb03783.x"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0888-6296(88)80005-X"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000539-199701000-00037"},{"key":"e_1_2_1_5_2","first-page":"333","article-title":"Perioperative volume effect of HES 120\/0.7 compared with dextran 70 and Ringer acetate.","volume":"85","author":"Hiippala S.","year":"1996","journal-title":"Ann Chir Gynaecol"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-198101000-00006"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1985.25385219903.x"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1213\/00000539-198709000-00009"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X9602400104"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/76.3.412"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1213\/00000539-199376060-00002"},{"key":"e_1_2_1_12_2","first-page":"25","article-title":"An experimental study on the effect of plasma expanders on blood coagulability.","volume":"26","author":"Narita T.","year":"1979","journal-title":"Bull Tokyo Med Dent Univ"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/69.3.307"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/70.2.173"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1988.28388219155.x"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000539-199609000-00003"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.1995.tb04049.x"},{"key":"e_1_2_1_18_2","first-page":"6","article-title":"The hemodynamic effect of various hydroxyethyl starch solutions in cardiosurgery patients.","volume":"39","author":"Boldt J.","year":"1990","journal-title":"Anaesthetist"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1985.25485273815.x"},{"key":"e_1_2_1_20_2","first-page":"615","article-title":"Studies on hydroxyethyl starch. Part II: Changes of the molecular weight distribution of hydroxyethyl starch types 450\/0.7, 450\/0.5, 450\/0.3, 300\/0.4, 200\/0.7, 200\/0.3 and 200\/0.1 after infusion in serum and urine of volunteers.","volume":"35","author":"Ferber HP","year":"1985","journal-title":"Drug Res"},{"key":"e_1_2_1_21_2","first-page":"15","volume-title":"Hydroxyethyl starch. A current overview","author":"F\u00f6rster H.","year":"1992"},{"key":"e_1_2_1_22_2","doi-asserted-by":"publisher","DOI":"10.1002\/j.1552-4604.1988.tb05751.x"},{"key":"e_1_2_1_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-198203000-00004"},{"key":"e_1_2_1_24_2","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1213\/00000539-199608000-00011","article-title":"Large\u2010dose administration of 6% hydroxyethyl starch 200\/0.5 for total hip arthroplasty: plasma homeostasis, hemostasis, and renal function compared to use of 5% human albumin.","volume":"83","author":"Vogt NH","year":"1996","journal-title":"Anesth Analg"},{"key":"e_1_2_1_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1988.tb09021.x"},{"key":"e_1_2_1_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000441-199011000-00006"},{"key":"e_1_2_1_27_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM198710083171517"},{"key":"e_1_2_1_28_2","doi-asserted-by":"publisher","DOI":"10.3171\/jns.1995.82.1.0044"},{"key":"e_1_2_1_29_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF00770880"},{"key":"e_1_2_1_30_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/78.6.684"},{"key":"e_1_2_1_31_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/77.6.809"},{"key":"e_1_2_1_32_2","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1182\/blood.V6.8.720.720","article-title":"The clot accelerating effect of dilution on blood and plasma. Relation to the mechanism of coagulation of normal and hemophiliac blood.","volume":"6","author":"Tocantinis LM","year":"1959","journal-title":"Blood"},{"key":"e_1_2_1_33_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/70.2.205"}],"container-title":["Acta Anaesthesiologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1399-6576.1998.tb05385.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1399-6576.1998.tb05385.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,28]],"date-time":"2023-10-28T10:18:40Z","timestamp":1698488320000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1399-6576.1998.tb05385.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1998,10]]},"references-count":32,"journal-issue":{"issue":"9","published-print":{"date-parts":[[1998,10]]}},"alternative-id":["10.1111\/j.1399-6576.1998.tb05385.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1399-6576.1998.tb05385.x","archive":["Portico"],"relation":{},"ISSN":["0001-5172","1399-6576"],"issn-type":[{"value":"0001-5172","type":"print"},{"value":"1399-6576","type":"electronic"}],"subject":[],"published":{"date-parts":[[1998,10]]}}}