{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T23:25:08Z","timestamp":1794525908416,"version":"4.9.1"},"reference-count":24,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2009,4,27]],"date-time":"2009-04-27T00:00:00Z","timestamp":1240790400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Anaesthesiol Scand"],"published-print":{"date-parts":[[2009,9]]},"abstract":"<jats:p><jats:bold>Background: <\/jats:bold> The pulse oximeter perfusion index (PI) has been used to indicate sympathectomy\u2010induced vasodilatation. We hypothesized that pulse oximeter PI provides an earlier and clearer indication of sympathectomy following epidural anesthesia than skin temperature and arterial pressure.<\/jats:p><jats:p><jats:bold>Methods: <\/jats:bold> Forty patients received lumbar epidural catheters. Patients were randomized to receive either 10\u2003ml 0.5% bupivacaine or 10\u2003ml 0.25% bupivacaine. PI in the toe, mean arterial pressure (MAP) and toe temperature were all assessed at baseline and at 5, 10 and 20\u2003min following epidural anesthesia. The effect of epidural anesthesia over time was assessed by repeated measures analysis of variance. Additionally, we defined clinically evident sympathectomy criteria (a 100% increase in the PI, a 15% decrease in MAP and a 1\u2003\u00b0C increase in toe temperature). The numbers of patients demonstrating these changes for each test were compared using the McNemar test for each time point.<\/jats:p><jats:p><jats:bold>Results: <\/jats:bold> Twenty\u2010nine subjects had photoplethysmography signals that met <jats:italic>a priori<\/jats:italic> signal quality criteria for analysis. By 20\u2003min, PI increased by 326%, compared with a 10% decrease and a 3% increase in MAP and toe temperature, respectively. For PI 15\/29, 26\/29 and 29\/29 of the subjects met the sympathectomy criteria at 5, 10 and 20\u2003min, respectively, compared with 4\/29, 6\/29 and 18\/29 for MAP changes and 3\/29, 8\/29 and 14\/29 for toe temperature changes.<\/jats:p><jats:p><jats:bold>Conclusions: <\/jats:bold> PI was an earlier, clearer and more sensitive indicator of the development of epidural\u2010induced sympathectomy than either skin temperature or MAP.<\/jats:p>","DOI":"10.1111\/j.1399-6576.2009.01968.x","type":"journal-article","created":{"date-parts":[[2009,4,27]],"date-time":"2009-04-27T13:28:23Z","timestamp":1240838903000},"page":"1018-1026","source":"Crossref","is-referenced-by-count":136,"title":["Pulse oximeter perfusion index as an early indicator of sympathectomy after epidural anesthesia"],"prefix":"10.1111","volume":"53","author":[{"given":"Y.","family":"GINOSAR","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C. F.","family":"WEINIGER","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Y.","family":"MEROZ","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V.","family":"KURZ","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.","family":"BDOLAH\u2010ABRAM","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"BABCHENKO","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"NITZAN","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E. M.","family":"DAVIDSON","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2009,8,7]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1213\/01.ane.0000198627.16144.77"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1213\/01.ane.0000189556.49429.16"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199403000-00005"},{"key":"e_1_2_6_5_2","first-page":"187","article-title":"Combined spinal\u2010epidural anesthesia for cesarean delivery","volume":"103","author":"Van de Velde M","year":"2006","journal-title":"dose-dependent effects of hyperbaric bupivacaine on maternal hemodynamics"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/0165-1838(94)90054-X"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/28\/3\/R01"},{"key":"e_1_2_6_8_2","first-page":"S31","article-title":"Photoplethysmography","volume":"105","author":"Shelley KH.","year":"2007","journal-title":"beyond the calculation of arterial oxygen saturation and heart rate"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0b013e31816c89e1"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02345149"},{"key":"e_1_2_6_11_2","first-page":"1250","article-title":"Combined photoplethysmographic monitoring of respiration rate and pulse","volume":"51","author":"Nilsson L","year":"2007","journal-title":"a comparison between different measurement sites in spontaneously breathing subjects"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.2005.00654.x"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.jp.7211328"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-200206000-00006"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/19\/1\/008"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/22\/2\/310"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1213\/01.ane.0000220947.02689.9f"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2005.02.075"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0952-8180(00)00207-5"},{"key":"e_1_2_6_20_2","first-page":"213","article-title":"Incidence of intraoperative hypotension as a function of the chosen definition","volume":"107","author":"Bijker JB","year":"2007","journal-title":"literature definitions applied to a retrospective cohort using automated data collection"},{"key":"e_1_2_6_21_2","first-page":"182","article-title":"Postanesthesia monitoring revisited","volume":"6","author":"Wiklund L","year":"1994","journal-title":"frequency of true and false alarms from different monitoring devices"},{"key":"e_1_2_6_22_2","first-page":"1360","article-title":"Multicentric study of monitoring alarms in the audit intensive care unit (ICU)","volume":"25","author":"Chambrin MC","year":"1999","journal-title":"a descriptive analysis"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.1991.tb03246.x"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-200005000-00022"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01618082"}],"container-title":["Acta Anaesthesiologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1399-6576.2009.01968.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1399-6576.2009.01968.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T16:37:41Z","timestamp":1696955861000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1399-6576.2009.01968.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,8,7]]},"references-count":24,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2009,9]]}},"alternative-id":["10.1111\/j.1399-6576.2009.01968.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1399-6576.2009.01968.x","archive":["Portico"],"relation":{},"ISSN":["0001-5172","1399-6576"],"issn-type":[{"value":"0001-5172","type":"print"},{"value":"1399-6576","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,8,7]]}}}