{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T23:11:05Z","timestamp":1792451465526,"version":"4.5.0"},"reference-count":85,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2010,7,28]],"date-time":"2010-07-28T00:00:00Z","timestamp":1280275200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Anaesthesiol Scand"],"published-print":{"date-parts":[[2010,10]]},"abstract":"<jats:p>The aim of the present paper is to review the literature regarding video\u2010laryngoscopes (Storz V\u2010Mac and C\u2010Mac, Glidescope, McGrath, Pentax\u2010Airway Scope, Airtraq and Bullard) and discuss their clinical role in airway management. Video\u2010laryngoscopes are new intubation devices, which provide an indirect view of the upper airway. In difficult airway management, they improve Cormack\u2013Lehane grade and achieve the same or a higher intubation success rate in less time, compared with direct laryngoscopes. Despite the very good visualization of the glottis, the insertion and advancement of the endotracheal tube with video\u2010laryngoscopes may occasionally fail. Each particular device's features may offer advantages or disadvantages, depending on the situation the anaesthesiologist has to deal with. So far, there is inconclusive evidence indicating that video\u2010laryngoscopy should replace direct laryngoscopy in patients with normal or difficult airways.<\/jats:p>","DOI":"10.1111\/j.1399-6576.2010.02285.x","type":"journal-article","created":{"date-parts":[[2010,7,28]],"date-time":"2010-07-28T09:29:24Z","timestamp":1280309364000},"page":"1050-1061","source":"Crossref","is-referenced-by-count":246,"title":["Video\u2010laryngoscopes in the adult airway management: a topical review of the literature"],"prefix":"10.1111","volume":"54","author":[{"given":"P.","family":"NIFOROPOULOU","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"I.","family":"PANTAZOPOULOS","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.","family":"DEMESTIHA","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E.","family":"KOUDOUNA","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.","family":"XANTHOS","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2010,7,28]]},"reference":[{"key":"e_1_2_12_2_2","first-page":"828","article-title":"Adverse respiratory events in anesthesia","volume":"72","author":"Caplan RA","year":"1990","journal-title":"a closed claims analysis"},{"key":"e_1_2_12_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03012147"},{"key":"e_1_2_12_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003643-200100003-00012"},{"key":"e_1_2_12_5_2","first-page":"372","article-title":"The airway","volume":"41","author":"Rose DK","year":"1994","journal-title":"problems and predictions in 18,500 patients"},{"key":"e_1_2_12_6_2","first-page":"203","article-title":"Voluntary reporting system in anaesthesia","volume":"9","author":"Bo\u00eblle PY","year":"2000","journal-title":"is there a link between undesirable and critical events?"},{"key":"e_1_2_12_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199112000-00021"},{"key":"e_1_2_12_8_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/65.3.400"},{"key":"e_1_2_12_9_2","first-page":"1269","article-title":"Practice guidelines for management of the difficult airway","volume":"98","author":"American Society of Anesthesiologists Task Force on Management of the Difficult Airway.","year":"2003","journal-title":"an updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway"},{"key":"e_1_2_12_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03027728"},{"key":"e_1_2_12_11_2","first-page":"60","article-title":"The Glidescope system","volume":"60","author":"Rai MR","year":"2005","journal-title":"a clinical assessment of performance"},{"key":"e_1_2_12_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00540-007-0513-2"},{"key":"e_1_2_12_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2008.05489.x"},{"key":"e_1_2_12_14_2","doi-asserted-by":"publisher","DOI":"10.1213\/01.ane.0000217211.12232.55"},{"key":"e_1_2_12_15_2","first-page":"218","article-title":"Videolaryngoscopy in the management of the difficult airway","volume":"26","author":"Stroumpoulis K","year":"2009","journal-title":"a comparison with the Macintosh blade"},{"key":"e_1_2_12_16_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2044.2000.01270.x"},{"key":"e_1_2_12_17_2","first-page":"429","article-title":"Predicting difficult intubation in apparently normal patients","volume":"103","author":"Shiga T","year":"2005","journal-title":"a meta-analysis of bedside screening test performance"},{"key":"e_1_2_12_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinane.2006.01.002"},{"key":"e_1_2_12_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0952-8180(02)00457-9"},{"key":"e_1_2_12_20_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03026792"},{"key":"e_1_2_12_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/MEJ.0b013e328303e1c6"},{"key":"e_1_2_12_22_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03016316"},{"key":"e_1_2_12_23_2","first-page":"517","article-title":"An evaluation of the Glidescope, a new video laryngoscope for difficult airways","volume":"23","author":"Benjamin FJ","year":"2006","journal-title":"a manikin study"},{"key":"e_1_2_12_24_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03022966"},{"key":"e_1_2_12_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.2009.02094.x"},{"key":"e_1_2_12_26_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aem303"},{"key":"e_1_2_12_27_2","first-page":"307","article-title":"Case series","volume":"54","author":"Shippey B","year":"2007","journal-title":"the McGrath videolaryngoscope- an initial clinical evaluation"},{"key":"e_1_2_12_28_2","first-page":"641","article-title":"The Pentax\u2010AWS rigid indirect v\u00eddeo laryngoscope","volume":"63","author":"Suzuki A","year":"2008","journal-title":"clinical assessment of performance in 320 cases"},{"key":"e_1_2_12_29_2","first-page":"191","article-title":"Pentax\u2010AWS (Airway Scope) and Airtraq","volume":"22","author":"Suzuki A","year":"2008","journal-title":"big difference between two similar devices"},{"key":"e_1_2_12_30_2","first-page":"81","article-title":"Airway scope","volume":"22","author":"Hirabayashi Y","year":"2008","journal-title":"early clinical experience in 405 patients"},{"key":"e_1_2_12_31_2","first-page":"160","article-title":"Airway scope","volume":"54","author":"Hirabayashi Y.","year":"2007","journal-title":"initial clinical experience with novice personnel"},{"key":"e_1_2_12_32_2","first-page":"257","article-title":"The Pentax\u2010AWS video\u2010laryngoscope","volume":"106","author":"Asai T","year":"2008","journal-title":"the first experience in one hundred patients"},{"key":"e_1_2_12_33_2","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0b013e31819c45e5"},{"key":"e_1_2_12_34_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03021065"},{"key":"e_1_2_12_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajem.2006.03.014"},{"key":"e_1_2_12_36_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.anes.0000282830.16579.e8"},{"key":"e_1_2_12_37_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aen211"},{"key":"e_1_2_12_38_2","first-page":"32","article-title":"Laryngoscopy via Macintosh blade versus Glidescope","volume":"110","author":"Nouruzi\u2010Sedeh P","year":"2009","journal-title":"success rate and time for endotracheal intubation in untrained medical personnel"},{"key":"e_1_2_12_39_2","first-page":"635","article-title":"Learning manual skills in anesthesiology","volume":"86","author":"Konrad C","year":"1998","journal-title":"is there a recommended number of cases for anesthetic procedures?"},{"key":"e_1_2_12_40_2","first-page":"451","article-title":"The clinical assessment of Glidescope in orotracheal intubation under general anesthesia","volume":"73","author":"Xue FS","year":"2007","journal-title":"Minerva Anestesiol"},{"key":"e_1_2_12_41_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2004.04038.x"},{"key":"e_1_2_12_42_2","first-page":"1378","article-title":"Evaluation of the Airway Scope, a new video laryngoscope, in tracheal intubation by na\u00efve operators","volume":"51","author":"Miki T","year":"2007","journal-title":"a manikin study"},{"key":"e_1_2_12_43_2","first-page":"128","article-title":"Comparison of the Glidescope, the Pentax AWS, and the Truview EVO2 with the Macintosh laryngoscope in experienced anaesthetists","volume":"102","author":"Malik MA","year":"2009","journal-title":"a manikin study"},{"key":"e_1_2_12_44_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinane.2008.08.024"},{"key":"e_1_2_12_45_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2008.05753.x"},{"key":"e_1_2_12_46_2","doi-asserted-by":"publisher","DOI":"10.1016\/0952-8180(91)90096-6"},{"key":"e_1_2_12_47_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-200303000-00007"},{"key":"e_1_2_12_48_2","doi-asserted-by":"publisher","DOI":"10.1080\/10903120802471881"},{"key":"e_1_2_12_49_2","doi-asserted-by":"publisher","DOI":"10.1186\/1471-227X-9-2"},{"key":"e_1_2_12_50_2","doi-asserted-by":"publisher","DOI":"10.1186\/1471-227X-9-9"},{"key":"e_1_2_12_51_2","doi-asserted-by":"publisher","DOI":"10.1080\/10903120802706070"},{"key":"e_1_2_12_52_2","first-page":"634","article-title":"Airway management after failure to intubate by direct laryngoscopy","volume":"52","author":"Burkle CM","year":"2005","journal-title":"outcomes in a large teaching hospital"},{"key":"e_1_2_12_53_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aen231"},{"key":"e_1_2_12_54_2","first-page":"381","article-title":"The Glidescope video Laryngoscope","volume":"94","author":"Sun DA","year":"2005","journal-title":"randomized clinical trial in 200 patients"},{"key":"e_1_2_12_55_2","first-page":"544","article-title":"Pentax\u2010AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements","volume":"100","author":"Enomoto Y","year":"2008","journal-title":"a randomized comparative study"},{"key":"e_1_2_12_56_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aep266"},{"key":"e_1_2_12_57_2","first-page":"910","article-title":"Cervical spine motion","volume":"101","author":"Turkstra TP","year":"2005","journal-title":"a fluoroscopic comparison during intubation with Lighted Stylet, Glidescope, and Macintosh Laryngoscope"},{"key":"e_1_2_12_58_2","first-page":"935","article-title":"Cervical spine motion during tracheal intubation with manual in\u2010line stabilization","volume":"106","author":"Robitaille A","year":"2008","journal-title":"direct laryngoscopy versus Glidescope videolaryngoscopy"},{"key":"e_1_2_12_59_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/ael133"},{"key":"e_1_2_12_60_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aen288"},{"key":"e_1_2_12_61_2","first-page":"563","article-title":"Randomized cross\u2010over comparison of cervical\u2010spine motion with the AirWay Scope or Macintosh laryngoscope with in\u2010line stabilization","volume":"101","author":"Maruyama K","year":"2008","journal-title":"a video-fluoroscopic study"},{"key":"e_1_2_12_62_2","first-page":"120","article-title":"Upper cervical spine movement during intubation","volume":"100","author":"Maruyama K","year":"2008","journal-title":"fluoroscopic comparison of the AirWay Scope, McCoy laryngoscope, and Macintosh laryngoscope"},{"key":"e_1_2_12_63_2","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0b013e31819fb44a"},{"key":"e_1_2_12_64_2","first-page":"1560","article-title":"A comparison of three videolaryngoscopes","volume":"109","author":"Maassen R","year":"2009","journal-title":"the Macintosh laryngoscope blade reduces, but does not replace, routine stylet use for intubation in morbidly obese patients"},{"key":"e_1_2_12_65_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-200703000-00027"},{"key":"e_1_2_12_66_2","first-page":"263","article-title":"Tracheal intubation of morbidly obese patients","volume":"100","author":"Ndoko SK","year":"2008","journal-title":"a randomized trial comparing performance of Macintosh and Airtraq laryngoscopes"},{"key":"e_1_2_12_67_2","first-page":"37","article-title":"Endotracheal intubation comparing a prototype Storz CMAC and a glidescope videolaryngoscope in a medical transport helicopter \u2013 a pilot study","volume":"142","author":"Boedeker BH","year":"2009","journal-title":"Stud Health Technol Inform"},{"key":"e_1_2_12_68_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2009.05964.x"},{"key":"e_1_2_12_69_2","first-page":"1283","article-title":"Awake endotracheal intubation in patients with cervical spine disease","volume":"81","author":"Cohn AI","year":"1995","journal-title":"a comparison of the Bullard laryngoscope and the Fiberoptic Bronchoscope"},{"key":"e_1_2_12_70_2","first-page":"564","article-title":"Awake intubation with Airtraq laryngoscope in a morbidly obese patient","volume":"91","author":"Uakritdathikarn T","year":"2008","journal-title":"J Med Assoc Thai"},{"key":"e_1_2_12_71_2","doi-asserted-by":"publisher","DOI":"10.1097\/ACO.0b013e3283184227"},{"key":"e_1_2_12_72_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03021635"},{"key":"e_1_2_12_73_2","first-page":"59","article-title":"Videolaryngoscopy for tracheal intubation","volume":"55","author":"Savoldelli GL","year":"2008","journal-title":"the guide channel or steering techniques for endotracheal tube placement?"},{"key":"e_1_2_12_74_2","first-page":"446","article-title":"Tracheal intubation with videolaryngoscopes in patients with cervical spine immobilization","volume":"103","author":"Liu EH","year":"2009","journal-title":"a randomized trial of the Airway Scope and the Glidescope"},{"key":"e_1_2_12_75_2","doi-asserted-by":"publisher","DOI":"10.1213\/ane.0b013e3181ae39db"},{"key":"e_1_2_12_76_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1992.tb02180.x"},{"key":"e_1_2_12_77_2","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X0803600620"},{"key":"e_1_2_12_78_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.otohns.2007.02.038"},{"key":"e_1_2_12_79_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03022329"},{"key":"e_1_2_12_80_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03021900"},{"key":"e_1_2_12_81_2","doi-asserted-by":"publisher","DOI":"10.1213\/ane.0b013e31818d1904"},{"key":"e_1_2_12_82_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinane.2008.02.004"},{"key":"e_1_2_12_83_2","first-page":"546","article-title":"Expected difficult tracheal intubation","volume":"102","author":"Jungbauer A","year":"2009","journal-title":"a prospective comparison of direct laryngoscopy and video laryngoscopy in 200 patients"},{"key":"e_1_2_12_84_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinane.2006.11.004"},{"key":"e_1_2_12_85_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aep191"},{"key":"e_1_2_12_86_2","first-page":"654","article-title":"Tracheal intubation in patients with cervical spine immobilization","volume":"102","author":"Malik MA","year":"2009","journal-title":"a comparison of the Airwayscope, LMA CTrach, and the Macintosh laryngoscopes"}],"container-title":["Acta Anaesthesiologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1399-6576.2010.02285.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1399-6576.2010.02285.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,31]],"date-time":"2023-10-31T11:47:25Z","timestamp":1698752845000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1399-6576.2010.02285.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,7,28]]},"references-count":85,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2010,10]]}},"alternative-id":["10.1111\/j.1399-6576.2010.02285.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1399-6576.2010.02285.x","archive":["Portico"],"relation":{},"ISSN":["0001-5172","1399-6576"],"issn-type":[{"value":"0001-5172","type":"print"},{"value":"1399-6576","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,7,28]]}}}