{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T18:23:10Z","timestamp":1761675790311},"reference-count":8,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2010,10,7]],"date-time":"2010-10-07T00:00:00Z","timestamp":1286409600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Anaesthesiol Scand"],"published-print":{"date-parts":[[2010,11]]},"abstract":"<jats:p><jats:bold>Background: <\/jats:bold> A commercially available pulse oximeter that reports blood haemoglobin (Hb) concentration is evaluated. This study considers whether this device can provide serial Hb data that would be sufficiently reliable for volume kinetic analysis of infusion fluids.<\/jats:p><jats:p><jats:bold>Methods: <\/jats:bold> Forty infusions of 5 or 10\u2003ml\/kg of acetated Ringer's solution were given over 15\u2003min in 10 healthy volunteers. Hb was measured on 17 different occasions over 120\u2003min using the Radical 7 pulse oximeter and compared with the result of invasive blood sampling (control). A one\u2010volume kinetic model was applied to each data series. The pulse oximeter also reported the perfusion index (PI).<\/jats:p><jats:p><jats:bold>Results: <\/jats:bold> The median deviation between the 680 invasive and non\u2010invasive Hb samples (the accuracy) was 1.6% and the absolute median deviation (precision) was 4.6%. Between\u2010subject factors explained half of the variation in the difference between non\u2010invasive vs. invasive sampling.<\/jats:p><jats:p>Ten of the 40 non\u2010invasive series of Hb values were discarded from kinetic analysis due to poor quality. The remaining 30 series showed a smaller distribution volume for the infused fluid when kinetic analysis was based on the non\u2010invasive method (3.0 vs. 5.3\u2003l; <jats:italic>P<\/jats:italic>&lt;0.001). This was due to co\u2010variance with the PI, which exaggerated the decrease in Hb caused by the infusions. The non\u2010invasive method might provide useful kinetic data at the group level, but individual curves deviated too much from the invasive data to be reliable.<\/jats:p><jats:p><jats:bold>Conclusions: <\/jats:bold> Non\u2010invasive measurement of the Hb concentration during volume loading could not provide useful kinetic data for individuals.<\/jats:p>","DOI":"10.1111\/j.1399-6576.2010.02321.x","type":"journal-article","created":{"date-parts":[[2010,10,7]],"date-time":"2010-10-07T16:42:09Z","timestamp":1286469729000},"page":"1233-1240","source":"Crossref","is-referenced-by-count":33,"title":["Non\u2010invasive monitoring of blood haemoglobin for analysis of fluid volume kinetics"],"prefix":"10.1111","volume":"54","author":[{"given":"R. G.","family":"HAHN","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Y.","family":"LI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"ZDOLSEK","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2010,10,7]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aen133"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1186\/cc6822"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.anes.0000268387.34758.6d"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.2008.01857.x"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.2009.03047.x"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199901000-00013"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0b013e3181dcd88f"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01143186"}],"container-title":["Acta Anaesthesiologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1399-6576.2010.02321.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1399-6576.2010.02321.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,31]],"date-time":"2023-10-31T12:50:50Z","timestamp":1698756650000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1399-6576.2010.02321.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,10,7]]},"references-count":8,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2010,11]]}},"alternative-id":["10.1111\/j.1399-6576.2010.02321.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1399-6576.2010.02321.x","archive":["Portico"],"relation":{},"ISSN":["0001-5172","1399-6576"],"issn-type":[{"value":"0001-5172","type":"print"},{"value":"1399-6576","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,10,7]]}}}