{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T23:18:51Z","timestamp":1783120731069,"version":"3.54.6"},"reference-count":19,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2011,10,14]],"date-time":"2011-10-14T00:00:00Z","timestamp":1318550400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Anaesthesiol Scand"],"published-print":{"date-parts":[[2012,2]]},"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Modern video laryngoscopes (<jats:styled-content style=\"fixed-case\">VLSs<\/jats:styled-content>) provide a superior view of the glottis, facilitating easier intubations. This study evaluates the forces applied to the maxillary incisors when using various <jats:styled-content style=\"fixed-case\">VLSs<\/jats:styled-content> and a <jats:styled-content style=\"fixed-case\">M<\/jats:styled-content>acintosh blade.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Fifty consecutive surgery patients were randomly assigned to receive laryngoscopy from a pair of four blades investigated in the study \u2013 the <jats:styled-content style=\"fixed-case\">VLS<\/jats:styled-content> <jats:styled-content style=\"fixed-case\">GlideScope<\/jats:styled-content><jats:sup>\u00ae<\/jats:sup> (Verathon Inc., Bothell, WA, USA), <jats:styled-content style=\"fixed-case\">V\u2010Mac<\/jats:styled-content>\u2122 <jats:styled-content style=\"fixed-case\">S<\/jats:styled-content>torz<jats:sup>\u00ae<\/jats:sup> (Karl Storz, Tuttlingen, Germany), and <jats:styled-content style=\"fixed-case\">McGrath<\/jats:styled-content>\u2122 (Aircraft Medical, Edinburgh, United Kingdom); and the classic <jats:styled-content style=\"fixed-case\">M<\/jats:styled-content>acintosh blade also from <jats:styled-content style=\"fixed-case\">S<\/jats:styled-content>torz<jats:sup>\u00ae<\/jats:sup> (Karl Storz). An endotracheal tube (<jats:styled-content style=\"fixed-case\">ETT<\/jats:styled-content>) was brought into position anterior to the vocal cords, with actual intubation carried out only with the second of the laryngoscopes. Sensors measured the forces directly applied to the patient's maxillary incisors while inserting the <jats:styled-content style=\"fixed-case\">ETT<\/jats:styled-content>. Other common metrics of intubation difficulty (e.g. <jats:styled-content style=\"fixed-case\">M<\/jats:styled-content>allampati grade, <jats:styled-content style=\"fixed-case\">C<\/jats:styled-content>ormack\u2013<jats:styled-content style=\"fixed-case\">L<\/jats:styled-content>ehane grade, and time) were also recorded.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Only one patient was not intubated within the standard study parameters and was converted to the hospital protocols for difficult intubations. The forces applied to the maxillary incisors were significantly greater with the <jats:styled-content style=\"fixed-case\">M<\/jats:styled-content>acintosh blade compared with all <jats:styled-content style=\"fixed-case\">VLSs<\/jats:styled-content>. There were no differences between the <jats:styled-content style=\"fixed-case\">VLSs<\/jats:styled-content> with regard to the forces. Patient characteristics, including <jats:styled-content style=\"fixed-case\">M<\/jats:styled-content>allampati grade, were not predictive of the forces applied.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>All <jats:styled-content style=\"fixed-case\">VLSs<\/jats:styled-content> considered were safer for the patient than was the <jats:styled-content style=\"fixed-case\">M<\/jats:styled-content>acintosh blade in terms of the forces applied to the maxillary teeth, time, number of insertion attempts, and view achieved of the glottic arch. There is a small, but significant, difference in the time and number of insertion attempts required during laryngoscopy with the different <jats:styled-content style=\"fixed-case\">VLSs<\/jats:styled-content>. There was no difference in the forces applied. The geometry of the respective blades may be an important component in the ease of laryngoscopy.<\/jats:p><\/jats:sec>","DOI":"10.1111\/j.1399-6576.2011.02541.x","type":"journal-article","created":{"date-parts":[[2011,10,14]],"date-time":"2011-10-14T14:50:18Z","timestamp":1318603818000},"page":"224-229","source":"Crossref","is-referenced-by-count":43,"title":["Forces applied to the maxillary incisors by video laryngoscopes and the <scp>M<\/scp>acintosh laryngoscope"],"prefix":"10.1111","volume":"56","author":[{"given":"R. A.","family":"LEE","sequence":"first","affiliation":[{"name":"Department of Biomechanical Engineering Delft University of Technology  Delft The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A. A. J.","family":"VAN ZUNDERT","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Intensive Care, and Pain Therapy Catharina Hospital \u2013 Brabant Medical School  Eindhoven The Netherlands"},{"name":"Department of Anesthesiology Faculty of Medicine University Ghent Hospital  Ghent Belgium"},{"name":"Department of Anesthesiology University of Maastricht Hospital  Maastricht The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R. L. J. G.","family":"MAASSEN","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Intensive Care, and Pain Therapy Catharina Hospital \u2013 Brabant Medical School  Eindhoven The Netherlands"},{"name":"Department of Anesthesiology University of Maastricht Hospital  Maastricht The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P. A.","family":"WIERINGA","sequence":"additional","affiliation":[{"name":"Department of Biomechanical Engineering Delft University of Technology  Delft The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2011,10,14]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF03027728"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF03022777"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1213\/ane.0b013e31818d1904"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinane.2003.06.004"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199905000-00013"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1213\/ANE.0b013e3181b7303a"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1213\/ane.0b013e3181ae39db"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1213\/00000539-199611000-00048"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF03017948"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF03011357"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00540-009-0780-1"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinane.2007.02.007"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF03021900"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1017\/S0265021506002067"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.2007.01450.x"},{"key":"e_1_2_6_17_1","first-page":"451","article-title":"The clinical assessment of Glidescope in orotracheal intubation under general anesthesia","volume":"73","author":"Xue FS","year":"2007","journal-title":"Minerva Anestesiol"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.2009.02119.x"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.2009.02094.x"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1994.tb04358.x"}],"container-title":["Acta Anaesthesiologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1399-6576.2011.02541.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1399-6576.2011.02541.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T15:39:27Z","timestamp":1695483567000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1399-6576.2011.02541.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,10,14]]},"references-count":19,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2012,2]]}},"alternative-id":["10.1111\/j.1399-6576.2011.02541.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1399-6576.2011.02541.x","archive":["Portico"],"relation":{},"ISSN":["0001-5172","1399-6576"],"issn-type":[{"value":"0001-5172","type":"print"},{"value":"1399-6576","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,10,14]]}}}