{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,18]],"date-time":"2025-12-18T19:33:34Z","timestamp":1766086414882},"reference-count":8,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2007,4,10]],"date-time":"2007-04-10T00:00:00Z","timestamp":1176163200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Vox Sanguinis"],"published-print":{"date-parts":[[2007,7]]},"abstract":"<jats:p><jats:bold>Background and Objectives\u2002<\/jats:bold> Reliable blood donor screening requires more accurate measure of haemoglobin (Hb) than by either copper sulphate or the haemoglobin colour scale. The HemoCue haemoglobinometer has established a method for this, but it is considerably more expensive; a modified version (HemoCue 301) has now been developed with a cheaper reagent\u2010free cuvette for use in budget\u2010restricted situations. This report describes evaluation of the performance, the assessment of reproducibility and accuracy of this modified analyser against the reference technique for Hb measurement.<\/jats:p><jats:p><jats:bold>Materials and Methods\u2002<\/jats:bold> Over 300 routine blood samples from specimens received routinely in a hospital laboratory were tested in accordance with the International Committee for Standardization in Haematology (ICSH) protocol. Accuracy and linearity were confirmed by the reference method with the WHO international haemoglobincyanide reference standard. Tests were also performed on selected samples for checking interference by biochemical abnormalities and leucocytosis. The effects of various sample storage conditions prior to testing were also tested.<\/jats:p><jats:p><jats:bold>Results\u2002<\/jats:bold> Ninety per cent of results were within 4% of true values, 96% within 6% and in only three cases was the deviation &gt; 10%, due to interference by bilirubinaemia and\/or C\u2010reactive protein. At an Hb value of 120 g\/l for donor selection, there were no cases where the method would have been misleading.<\/jats:p><jats:p><jats:bold>Conclusion\u2002<\/jats:bold> HemoCue 301 provides a simple and reliable anaemia screen method, conforming to the requirements of CLIA\u201988 regulations; it is reliable for discriminating Hb values for donor acceptance. The main advantage is that the cuvettes are significantly cheaper than the previous models, and will not deteriorate in adverse climatic conditions.<\/jats:p>","DOI":"10.1111\/j.1423-0410.2007.00919.x","type":"journal-article","created":{"date-parts":[[2007,4,26]],"date-time":"2007-04-26T06:08:11Z","timestamp":1177567691000},"page":"64-69","source":"Crossref","is-referenced-by-count":39,"title":["Evaluation of the utility of the HemoCue 301 haemoglobinometer for blood donor screening"],"prefix":"10.1111","volume":"93","author":[{"given":"L. D.","family":"Morris","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Osei\u2010Bimpong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"McKeown","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"Roper","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S. M.","family":"Lewis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2007,4,10]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1423-0410.2001.00013.x"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1136\/jcp.51.1.21"},{"key":"e_1_2_6_4_2","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1093\/clinchem\/32.3.526","article-title":"Evaluation of \u2018HemoCue\u2019, a new device for determining hemoglobin","volume":"32","author":"Von Schenck H","year":"1985","journal-title":"Clin Chem"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.294.6582.1263"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1136\/jcp.2004.018366"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2257.1984.tb00528.x"},{"key":"e_1_2_6_8_2","unstructured":"Federal register:Clinical laboratory improvement amendments of 1988; Final rules and notices. 28 February 1992 7188\u20137288"},{"key":"e_1_2_6_9_2","first-page":"669","volume-title":"Dacie and Lewis Practical Haematology","author":"Lewis SM","year":"2006"}],"container-title":["Vox Sanguinis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1423-0410.2007.00919.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1423-0410.2007.00919.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,9]],"date-time":"2023-10-09T18:45:38Z","timestamp":1696877138000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1423-0410.2007.00919.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,4,10]]},"references-count":8,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2007,7]]}},"alternative-id":["10.1111\/j.1423-0410.2007.00919.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1423-0410.2007.00919.x","archive":["Portico"],"relation":{},"ISSN":["0042-9007","1423-0410"],"issn-type":[{"value":"0042-9007","type":"print"},{"value":"1423-0410","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,4,10]]}}}