{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,17]],"date-time":"2025-06-17T09:07:50Z","timestamp":1750151270244},"reference-count":23,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2012,9,12]],"date-time":"2012-09-12T00:00:00Z","timestamp":1347408000000},"content-version":"vor","delay-in-days":11,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Paediatrics Child Health"],"published-print":{"date-parts":[[2012,9]]},"abstract":"<jats:p><jats:bold>Background:\u2003<\/jats:bold> Delivery room resuscitation of hypoxic newborn infants with pure or 100% oxygen causes oxidative toxicity and increases mortality. Current international resuscitation guidelines therefore recommend that oxygen be used judiciously. However, this requires staff education and special equipment that may not be available in non\u2010tertiary maternity hospitals where the majority of births occur.<\/jats:p><jats:p><jats:bold>Aim:\u2003<\/jats:bold> To determine current attitudes, practices and available equipment for the use of air and blended oxygen for newborn delivery room resuscitation in non\u2010tertiary maternity hospitals of Australia and New Zealand (ANZ).<\/jats:p><jats:p><jats:bold>Methods:\u2003<\/jats:bold> Structured questionnaires sent by mail and e\u2010mail after personal phone contact. A total of 203 eligible hospitals in ANZ were identified. A second mailing was conducted a month later for non\u2010responders.<\/jats:p><jats:p><jats:bold>Responders:\u2003<\/jats:bold> Final response rate was 64% (<jats:italic>n<\/jats:italic>= 130: 70% physicians, 30% midwives). The majority (121, 93%) of respondents were aware of Australian Resuscitation Council recommendations, but only one in five hospitals had the capacity to deliver blended oxygen and 38% used pulse oximeters at delivery. Only 24 (18.5%) hospitals had guidelines. Air would be used by 68 (57%) hospitals to resuscitate term infants compared to 35 (31%) for preterm infants. Most (111, 91%) advocated the use of blended oxygen despite the lack of facilities.<\/jats:p><jats:p><jats:bold>Conclusion:\u2003<\/jats:bold> Only one in five ANZ non\u2010tertiary maternity hospitals had the capacity to resuscitate newborn infants with air or blended oxygen. Most are aware of current recommendations and agreed that the use of less oxygen would be beneficial for this purpose. Further study into the necessary infrastructure required to implement these guidelines are recommended.<\/jats:p>","DOI":"10.1111\/j.1440-1754.2012.02545.x","type":"journal-article","created":{"date-parts":[[2012,9,13]],"date-time":"2012-09-13T03:48:10Z","timestamp":1347508090000},"page":"828-832","update-policy":"http:\/\/dx.doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Use of oxygen for delivery room neonatal resuscitation in non\u2010tertiary Australian and New Zealand hospitals: A survey of current practices, opinions and equipment"],"prefix":"10.1111","volume":"48","author":[{"given":"Kavita","family":"Bhola","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kei","family":"Lui","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ju Lee","family":"Oei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2012,9,12]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1440-1754.2006.00779.x"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.107.4.642"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.102.1.e1"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.CD002273.pub3"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-199307000-00024"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1089\/152308604771978462"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1159\/000128117"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1440-1754.2007.01021.x"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2006-0350"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1440-1754.2008.01430.x"},{"issue":"1","key":"e_1_2_7_12_2","article-title":"NSW Department of Health. New South Wales Mothers and Babies 2007","volume":"21","author":"Centre for Epidemiology and Research","year":"2010","journal-title":"N. S. W. Public Health Bull."},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2702.2007.02087.x"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2393-10-26"},{"issue":"1","key":"e_1_2_7_15_2","first-page":"118","article-title":"2005 American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Part 13: neonatal resuscitation guidelines","volume":"112","author":"American Heart Association","year":"2005","journal-title":"Circulation"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa0911781"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2009-0434"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1651-2227.2005.tb02086.x"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(04)17189-4"},{"key":"e_1_2_7_20_2","doi-asserted-by":"publisher","DOI":"10.1159\/000080950"},{"key":"e_1_2_7_21_2","first-page":"A15","article-title":"The TO2PIDO Multinational Study Group. Feasibility of a randomised trial of targeted oxygen for the resuscitation of premature infants and their developmental outcome (TO2RPIDO)","volume":"45","author":"See KC","year":"2009","journal-title":"J. Paediatr. Child Health"},{"key":"e_1_2_7_22_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1741-6787.2009.00167.x"},{"key":"e_1_2_7_23_2","first-page":"398","article-title":"Knowledge and practice of universal precautions against blood borne pathogens amongst house officers and nurses in tertiary health institutions in Southeast Nigeria","volume":"12","author":"Adinma ED","year":"2009","journal-title":"Niger. J. Clin. Pract."},{"key":"e_1_2_7_24_2","unstructured":"The Australian Resuscitation Council.Australian Resuscitation Council Neonatal Resuscitation Guidelines.2010. Available from:http:\/\/www.resus.org.au[accessed 21 May 2011]."}],"container-title":["Journal of Paediatrics and Child Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1440-1754.2012.02545.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1440-1754.2012.02545.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,30]],"date-time":"2023-10-30T21:30:19Z","timestamp":1698701419000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1440-1754.2012.02545.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,9]]},"references-count":23,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2012,9]]}},"alternative-id":["10.1111\/j.1440-1754.2012.02545.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1440-1754.2012.02545.x","archive":["Portico"],"relation":{},"ISSN":["1034-4810","1440-1754"],"issn-type":[{"value":"1034-4810","type":"print"},{"value":"1440-1754","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,9]]},"assertion":[{"value":"2012-09-12","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}