{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T03:18:40Z","timestamp":1770434320281,"version":"3.49.0"},"reference-count":30,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2009,10,8]],"date-time":"2009-10-08T00:00:00Z","timestamp":1254960000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Respirology"],"published-print":{"date-parts":[[2009,11]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:p><jats:bold>Background and objective:\u2003<\/jats:bold> The SD\u2010101 is a non\u2010restrictive, sheet\u2010like medical device with an array of pressure sensors, to detect sleep\u2010disordered breathing by sensing gravitational alterations in the body corresponding to respiratory movements. This study evaluated the accuracy of the SD\u2010101 for screening sleep apnoea\u2010hypopnoea syndrome (SAHS) by comparison with polysomnography.<\/jats:p><jats:p><jats:bold>Methods:\u2003<\/jats:bold> Nocturnal polysomnography and SD\u2010101 monitoring were conducted simultaneously and compared in 201 patients with suspected SAHS (suspected SAHS group) and 165 male employees of a transport company (screening group).<\/jats:p><jats:p><jats:bold>Results:\u2003<\/jats:bold> Polysomnography revealed an AHI of &lt;5, 5\u2003\u2264\u2003AHI\u2003&lt;\u200315, 15\u2003\u2264\u2003AHI\u2003&lt;\u200330, 30\u2003\u2264\u2003AHI\u2003&lt;\u200360 and AHI\u2003\u2265\u200360 events\/h in 39, 35, 38, 68 and 21 subjects in the suspected SAHS group and 103, 34, 12, 12 and four subjects in the screening group, respectively. Central SAHS and obstructive SAHS were subsequently diagnosed in 11 (5.5%) and 135 (67.2%) of subjects in the suspected SAHS group and five (3.0%) and 39 (23.6%) of subjects in the screening group, respectively. Significant correlations were apparent between AHI and the respiratory disturbance index (RDI) measured with the SD\u2010101 in both the suspected SAHS group (<jats:italic>r<\/jats:italic>\u2003=\u20030.88) and screening group (<jats:italic>r<\/jats:italic>\u2003=\u20030.92). Receiver operating characteristic curve analysis revealed 89.5% sensitivity and 85.8% specificity in identifying SAHS, using an RDI of 14.0 events\/h.<\/jats:p><jats:p><jats:bold>Conclusions:\u2003<\/jats:bold> These findings suggest that the SD\u2010101 is a useful device for screening SAHS.<\/jats:p>","DOI":"10.1111\/j.1440-1843.2009.01627.x","type":"journal-article","created":{"date-parts":[[2009,10,8]],"date-time":"2009-10-08T08:33:34Z","timestamp":1254990814000},"page":"1143-1150","source":"Crossref","is-referenced-by-count":36,"title":["A novel device (SD\u2010101) with high accuracy for screening sleep apnoea\u2010hypopnoea syndrome"],"prefix":"10.1111","volume":"14","author":[{"given":"Toshihiko","family":"AGATSUMA","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keisaku","family":"FUJIMOTO","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshimichi","family":"KOMATSU","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuhisa","family":"URUSHIHATA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takayuki","family":"HONDA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Teruomi","family":"TSUKAHARA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tetsuo","family":"NOMIYAMA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2009,10,22]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1513\/pats.200708-139MG"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.290.14.1906"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(02)07445-7"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9343(02)01570-X"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2008.05.002"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(05)71141-7"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM198903303201314"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm.154.1.8680676"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1136\/thorax.56.7.508"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199304293281704"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.2486\/indhealth.46.233"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1093\/sleep\/31.3.419"},{"key":"e_1_2_7_14_2","first-page":"737","article-title":"Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients. Portable Monitoring Task Force of the American Academy of Sleep Medicine","volume":"15","author":"Collop NA","year":"2007","journal-title":"J. Clin. Sleep Med."},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.7210\/jrsj.16.705"},{"key":"e_1_2_7_16_2","first-page":"S244","article-title":"A study of respiration detecting algorithm using pressure sensor","volume":"22","author":"Yamanaka K","year":"2002","journal-title":"Jpn. Associa. Med. Inf."},{"key":"e_1_2_7_17_2","first-page":"794","article-title":"Clinical evaluation of portable overnight sleep respiration graph for diagnosis of sleep apnea syndrome","volume":"42","author":"Takasaki Y","year":"2004","journal-title":"Nihon Kokyuki Gakkai Zasshi"},{"key":"e_1_2_7_18_2","first-page":"181","article-title":"Clinical usefulness and health\u2010economic benefits of a new sheet\u2010like medical device (SD\u2010101) for the diagnosis of sleep apnea syndrome","volume":"46","author":"Takasaki Y","year":"2008","journal-title":"Nihon Kokyuki Gakkai Zasshi"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1093\/sleep\/28.4.499"},{"key":"e_1_2_7_20_2","first-page":"51","volume-title":"The International Classification of Sleep Disorders","author":"American Academy of Sleep Medicine","year":"2005"},{"key":"e_1_2_7_21_2","first-page":"372","article-title":"ASDA standards of practice: practice parameters for the use of portable recording in the assessment of obstructive sleep apnea","volume":"22","author":"Standards of Practice Committee of the American Sleep Disorders Association","year":"1994","journal-title":"Sleep"},{"key":"e_1_2_7_22_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.89.4.533"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.1136\/thx.50.11.1201"},{"key":"e_1_2_7_24_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.101.5.1221"},{"key":"e_1_2_7_25_2","doi-asserted-by":"publisher","DOI":"10.1590\/S0100-879X2000000500005"},{"key":"e_1_2_7_26_2","doi-asserted-by":"publisher","DOI":"10.1183\/09031936.03.00298103"},{"key":"e_1_2_7_27_2","article-title":"Validation of the WristOx 3100\u2122 oximeter for the diagnosis of sleep apnea\/hypopnea syndrome","author":"Nigro CA","year":"2008","journal-title":"Sleep Breath."},{"key":"e_1_2_7_28_2","article-title":"Design, construction and evaluation of an ambulatory device for screening of sleep apnea","author":"Tiihonen P","year":"2008","journal-title":"Med. Biol. Eng. Comput."},{"key":"e_1_2_7_29_2","article-title":"Significance of a screening device (Apnomonitor 5\u00ae) for sleep apnea syndrome","author":"Yagi H","year":"2008","journal-title":"Auris Nasus Larynx"},{"key":"e_1_2_7_30_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.94.1.9"},{"key":"e_1_2_7_31_2","doi-asserted-by":"publisher","DOI":"10.2169\/naika.93.1147"}],"container-title":["Respirology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1440-1843.2009.01627.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1440-1843.2009.01627.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,14]],"date-time":"2023-10-14T13:14:38Z","timestamp":1697289278000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1440-1843.2009.01627.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,10,22]]},"references-count":30,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2009,11]]}},"alternative-id":["10.1111\/j.1440-1843.2009.01627.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1440-1843.2009.01627.x","archive":["Portico"],"relation":{},"ISSN":["1323-7799","1440-1843"],"issn-type":[{"value":"1323-7799","type":"print"},{"value":"1440-1843","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,10,22]]}}}