{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T15:40:44Z","timestamp":1774971644461,"version":"3.50.1"},"reference-count":13,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2005,5,31]],"date-time":"2005-05-31T00:00:00Z","timestamp":1117497600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clinical Exper Ophthalmology"],"published-print":{"date-parts":[[2005,6]]},"abstract":"<jats:title>A<jats:sc>bstract<\/jats:sc><\/jats:title><jats:p><jats:bold>Background:\u2002<\/jats:bold> The purpose of the present study was to determine the agreement between stereo photography, Heidelberg retina tomograph (HRT), digital stereoscopic optic disc camera (DISCAM) and ophthalmoscopy in estimating the vertical cup\u2003:\u2003disc ratio (VCDR).<\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold> One hundred and ninety\u2010nine eyes of 100 subjects from glaucoma clinics were examined by a single glaucoma specialist and the VCDR on ophthalmoscopy was recorded. All eyes were classified as definite glaucoma, glaucoma suspect or no glaucoma based on the entire clinical assessment. Two glaucoma specialists viewed stereo photographs of the eyes separately and independently. A trained technician acquired HRT and DISCAM images. The agreement of VCDR among the four modalities was assessed by the method described by Bland and Altman.<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold> Of the 199 eyes, 28.1% were classified as definite glaucoma, 36.2% as glaucoma suspect and 35.7% as no glaucoma. The 2\u2003SD for the agreement between the two glaucoma specialists using stereo photographs was 0.18 VCDR. The 2\u2003SD for the agreement between stereo photographs and HRT, DISCAM and ophthalmoscopy were 0.31, 0.31 and 0.28, respectively. The 2\u2003SD for ophthalmoscopy and HRT was 0.32, for ophthalmoscopy and DISCAM it was 0.32, and for HRT and DISCAM it was 0.22. When the eyes were divided into tertiles according disc size and VCDR, the 2\u2003SD was higher for smaller optic discs (&lt;1.5\u2003mm vertical height) and smaller optic cups (VCDR &lt;0.4).<\/jats:p><jats:p><jats:bold>Conclusions:\u2002<\/jats:bold> There was good agreement between VCDR values estimated independently using stereo photographs by the two clinicians. However, when the different modalities were compared using Bland and Altman analysis, all showed poor agreement with a large 2\u2003SD. The agreement was worse for small discs and smaller cups. The VCDR values obtained by the different methods were found not to be interchangeable in a clinic setting.<\/jats:p>","DOI":"10.1111\/j.1442-9071.2005.01000.x","type":"journal-article","created":{"date-parts":[[2005,6,20]],"date-time":"2005-06-20T23:20:54Z","timestamp":1119309654000},"page":"259-263","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Agreement between stereoscopic photographs, clinical assessment, Heidelberg retina tomograph and digital stereoscopic optic disc camera in estimating verticalcup:disc ratio"],"prefix":"10.1111","volume":"33","author":[{"given":"Thiran","family":"Jayasundera","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Helen V","family":"Danesh\u2010Meyer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark","family":"Donaldson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Greg","family":"Gamble","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2005,5,31]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1979.01020020106002"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1980.01020030486010"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(92)31990-6"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(88)33177-5"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.86.2.196"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(01)00983-6"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(03)00496-2"},{"key":"e_1_2_6_10_2","first-page":"400","article-title":"Validity of two\u2010dimensional data obtained with the Heidelberg Retina Tomograph as verified by direct measurements in normal optic nerve heads","volume":"3","author":"Bartz\u2010Schmidt KU","year":"1994","journal-title":"Ger J Ophthalmol"},{"key":"e_1_2_6_11_2","volume-title":"Discam","author":"Marcher Enterprises.","year":"2002"},{"key":"e_1_2_6_12_2","volume-title":"Heidelberg Retinal Tomograph II Operating Instructions Software, Version 1. 6.","author":"Heidelberg Engineering.","year":"2001"},{"key":"e_1_2_6_13_2","first-page":"1151","article-title":"Optic disc, cup and neuroretinal rim size, configuration and correlations in normal eyes","volume":"29","author":"Jonas JB","year":"1988","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.82.4.362"}],"container-title":["Clinical &amp; Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1442-9071.2005.01000.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1442-9071.2005.01000.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,9]],"date-time":"2023-10-09T19:19:14Z","timestamp":1696879154000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1442-9071.2005.01000.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,5,31]]},"references-count":13,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2005,6]]}},"alternative-id":["10.1111\/j.1442-9071.2005.01000.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1442-9071.2005.01000.x","archive":["Portico"],"relation":{},"ISSN":["1442-6404","1442-9071"],"issn-type":[{"value":"1442-6404","type":"print"},{"value":"1442-9071","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,5,31]]},"assertion":[{"value":"2005-05-31","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}