{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T22:48:19Z","timestamp":1791845299418,"version":"4.3.4"},"reference-count":45,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2007,4,11]],"date-time":"2007-04-11T00:00:00Z","timestamp":1176249600000},"content-version":"vor","delay-in-days":10,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clinical Exper Ophthalmology"],"published-print":{"date-parts":[[2007,4]]},"abstract":"<jats:title>\n                    A\n                    <jats:sc>bstract<\/jats:sc>\n                  <\/jats:title>\n                  <jats:p>\n                    <jats:bold>Purpose:\u2002<\/jats:bold>\n                    Portable, telemedicine\u2010friendly devices offer novel opportunity for screening and monitoring glaucoma in the remote and rural regions of the world. This study examines the effective combination of telemedicine\u2010friendly screening devices for detection of glaucoma in relation with conventional, hospital\u2010based devices.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Methods:\u2002<\/jats:bold>\n                    A total of 399 eyes were screened with telemedicine\u2010friendly devices and conventional, hospital\u2010based devices such as ophthalmoscope, tonometer and perimeter.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Results:\u2002<\/jats:bold>\n                    Combination of age and family history of glaucoma alone has a sensitivity of 35.6% (specificity 94.2%, area under the curve 0.81, correctly classified 81.1%) and an addition of telemedicine\u2010friendly or conventional visual field tests optimized the sensitivity to 91.1% (specificity 93.6%, area under the curve 0.95, correctly classified 93%). Analysis indicates good agreement between vertical cup\u2010to\u2010disc ratio by ophthalmoscopy and digital image reading. An addition of intraocular pressure test does not change sensitivity (35.6%) and specificity (94.2%).\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Conclusion:\u2002<\/jats:bold>\n                    This study indicates that evaluations of cup\u2010to\u2010disc ratio and visual field, using telemedicine\u2010friendly devices, are most useful tools in screening for glaucoma. When used together these devices may be an alternative for conventional glaucoma screenings.\n                  <\/jats:p>","DOI":"10.1111\/j.1442-9071.2007.01457.x","type":"journal-article","created":{"date-parts":[[2007,4,11]],"date-time":"2007-04-11T04:29:23Z","timestamp":1176265763000},"page":"237-243","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":55,"title":["Glaucoma screening: analysis of conventional and telemedicine\u2010friendly devices"],"prefix":"10.1111","volume":"35","author":[{"given":"Sajeesh","family":"Kumar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Giubilato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William","family":"Morgan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ludmila","family":"Jitskaia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chris","family":"Barry","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Max","family":"Bulsara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ian J","family":"Constable","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kanagasingam","family":"Yogesan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2007,4,11]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2005.081224"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.5694\/j.1326-5377.2004.tb06468.x"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(05)67505-8"},{"key":"e_1_2_6_5_2","first-page":"45","article-title":"Tele\u2010glaucoma: use of digital devices and web\u2010based system for screening and detection of glaucoma","volume":"10","author":"Yogesan K","year":"2004","journal-title":"Telemed J E Health"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1370\/afm.293"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1177\/096228029900800204"},{"key":"e_1_2_6_8_2","doi-asserted-by":"crossref","unstructured":"BlandJM AltmanDG.Statistical methods for assessing agreement between two methods of clinical measurements.Lancet1986 307\u201310.","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-200408000-00010"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(01)00799-0"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2005.072579"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-199912000-00005"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1089\/107830299312032"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-199910000-00004"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.1998.tb01385.x"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199908000-00022"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/00055735-200104000-00005"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0008-4182(05)80010-9"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(14)72062-8"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01015-1"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.117.11.1479"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(00)00354-8"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-200202000-00009"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-200306000-00007"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.2000.tb01083.x"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2003.12.009"},{"key":"e_1_2_6_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(88)33176-3"},{"key":"e_1_2_6_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(98)00047-6"},{"key":"e_1_2_6_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(01)00988-5"},{"key":"e_1_2_6_30_2","doi-asserted-by":"publisher","DOI":"10.1159\/000027398"},{"key":"e_1_2_6_31_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.ijg.0000151883.07232.54"},{"key":"e_1_2_6_32_2","first-page":"195","article-title":"Frequency doubling perimetry and the detection of eye disease in the community","volume":"98","author":"Cioffi GA","year":"2000","journal-title":"Trans Am Ophthalmol Soc"},{"key":"e_1_2_6_33_2","unstructured":"American Academy of Ophthalmology Preferred Practice Pattern Committee Glaucoma Panel.Primary Open\u2010Angle Glaucoma Limited Revision.2003. Accessed 18 Feb 2007. Available from:http:\/\/www.aao.org\/aao\/education\/library\/ppp\/upload\/Primary\u2010Open\u2010Angle\u2010Glaucoma_.pdf"},{"key":"e_1_2_6_34_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.1995.tb00152.x"},{"key":"e_1_2_6_35_2","doi-asserted-by":"publisher","DOI":"10.1126\/science.1066901"},{"key":"e_1_2_6_36_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.120.6.701"},{"key":"e_1_2_6_37_2","doi-asserted-by":"publisher","DOI":"10.1038\/eye.1993.26"},{"key":"e_1_2_6_38_2","doi-asserted-by":"publisher","DOI":"10.1076\/opep.9.5.333.10335"},{"key":"e_1_2_6_39_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.331.7517.E376"},{"key":"e_1_2_6_40_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.38506.594977.E0"},{"key":"e_1_2_6_41_2","first-page":"1184","article-title":"Rationale for the USPSTF recommendation on screening for glaucoma","volume":"72","author":"Guirguis J","year":"2005","journal-title":"Am Fam Physician"},{"key":"e_1_2_6_42_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.ijg.0000169413.94010.02"},{"key":"e_1_2_6_43_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2006.01275.x"},{"key":"e_1_2_6_44_2","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-199806000-00010"},{"key":"e_1_2_6_45_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.2005.00514.x"},{"key":"e_1_2_6_46_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0420.2002.800613.x"}],"container-title":["Clinical &amp; Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1442-9071.2007.01457.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1442-9071.2007.01457.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T01:42:24Z","timestamp":1696902144000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1442-9071.2007.01457.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,4]]},"references-count":45,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2007,4]]}},"alternative-id":["10.1111\/j.1442-9071.2007.01457.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1442-9071.2007.01457.x","archive":["Portico"],"relation":{},"ISSN":["1442-6404","1442-9071"],"issn-type":[{"value":"1442-6404","type":"print"},{"value":"1442-9071","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,4]]},"assertion":[{"value":"2007-04-11","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}