{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,25]],"date-time":"2026-02-25T05:59:09Z","timestamp":1771999149758,"version":"3.50.1"},"reference-count":25,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2008,4,13]],"date-time":"2008-04-13T00:00:00Z","timestamp":1208044800000},"content-version":"vor","delay-in-days":12,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clinical Exper Ophthalmology"],"published-print":{"date-parts":[[2008,4]]},"abstract":"<jats:title>A<jats:sc>bstract<\/jats:sc><\/jats:title><jats:p><jats:bold>Background:\u2002<\/jats:bold> This study measured the capsular bag diameter (CBD) of Asian eyes using a modified capsular measuring ring (CMR) after cataract surgery, and identified preoperative predictive factors for postoperative CBD and the change of capsular bag diameter after surgery.<\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold> This prospective study followed 25 eyes undergoing cataract surgery inserted with a CMR before intraocular lens (IOL) implantation at the Department of Ophthalmology, Ilsan Paik Hospital, Inje University, Republic of Korea. Axial length (AL), anterior chamber depth (ACD), lens thickness, corneal power and corneal size were measured preoperatively. CBD was calculated using the CMR in a dilated state at postoperative 1 day, 1 week, 1 month, 2 months, and 1 year.<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold> AL (<jats:italic>R<\/jats:italic>\u2003=\u20030.713) and ACD (<jats:italic>R<\/jats:italic>\u2003=\u20030.402) were found to positively correlate with CBD at postoperative 1 week. AL (<jats:italic>P<\/jats:italic>\u2003&lt;\u20030.001) and ACD (<jats:italic>P<\/jats:italic>\u2003=\u20030.046) were found to be predictors of CBD. The mean CBD gradually decreased to 11.30\u2003\u00b1\u20031.76\u2003mm at 1 day, 10.86\u2003\u00b1\u20031.06\u2003mm at 1 week, 10.23\u2003\u00b1\u20031.43\u2003mm at 1 month, 9.88\u2003\u00b1\u20031.31\u2003mm at 2 months, and 9.85\u2003\u00b1\u20031.43\u2003mm at 1 year.<\/jats:p><jats:p><jats:bold>Conclusion:\u2002<\/jats:bold> CBD size could be determined using a CMR implanted during surgery. AL and ACD were predictors of postoperative CBD. Predicting CBD in this way may assist in selecting appropriately sized IOL, which will lead to improved visual quality after cataract surgery.<\/jats:p>","DOI":"10.1111\/j.1442-9071.2008.01726.x","type":"journal-article","created":{"date-parts":[[2008,4,14]],"date-time":"2008-04-14T06:10:18Z","timestamp":1208153418000},"page":"238-244","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":28,"title":["The analysis of predicted capsular bag diameter using modified model of capsule measuring ring in Asians"],"prefix":"10.1111","volume":"36","author":[{"given":"Jin\u2010Hyoung","family":"Kim","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Doh","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Young\u2010Dong","family":"Cha","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sae\u2010Hoon","family":"Oh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ki\u2010Choong","family":"Mah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Moo\u2010Suk","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2008,4,13]]},"reference":[{"key":"e_1_2_6_2_2","first-page":"42","article-title":"Lens material and design affect visual outcome","volume":"25","author":"Oslo RJ.","year":"2000","journal-title":"Ophthalmol Times"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(98)80323-4"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(99)90047-7"},{"key":"e_1_2_6_5_2","first-page":"47","article-title":"Comparison of anterior capsular opening after silicone intraocular lens implantation with and without capsular tension ring","volume":"41","author":"Cheon HJ","year":"2000","journal-title":"J Korean Ophthalmol Soc"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00610-6"},{"key":"e_1_2_6_7_2","doi-asserted-by":"crossref","first-page":"502","DOI":"10.3928\/1542-8877-19980601-12","article-title":"InVitro evaluation of the efficacy of the capsular tension ring for managing zonular dialysis in cataract surgery","volume":"29","author":"Sun R","year":"1998","journal-title":"Ophthalmic Surg Lasers"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(01)01174-9"},{"key":"e_1_2_6_9_2","doi-asserted-by":"crossref","first-page":"273","DOI":"10.3928\/1542-8877-19970401-03","article-title":"Management of zonular dialysis in Phacoemulsification and IOL implantation using the capsular tension ring","volume":"28","author":"Gimbel HV","year":"1997","journal-title":"Ophthalmic Surg Lasers"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.3341\/kjo.2005.19.1.23"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1159\/000267512"},{"key":"e_1_2_6_12_2","first-page":"426","article-title":"Intraobserver and Interobserver reproducibility of the NIDEK EAS\u20101000 anterior eye segment analysis system","volume":"23","author":"Baez KA","year":"1992","journal-title":"Ophthalmic Surg"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2005.01029.x"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1992.01080140020007"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(97)80027-2"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00352-3"},{"key":"e_1_2_6_17_2","doi-asserted-by":"crossref","first-page":"194","DOI":"10.3928\/1081-597X-20050301-17","article-title":"Racial differences in central corneal thickness and refraction among refractive surgery candidates","volume":"21","author":"Yo C","year":"2005","journal-title":"J Refract Surg"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(03)00424-0"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1038\/eye.1994.20"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0146-2776(83)80072-X"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0146-2776(84)80056-7"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2003.12.031"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00204-7"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.3341\/kjo.2001.15.1.22"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(98)80329-5"},{"key":"e_1_2_6_26_2","unstructured":"RosenthalKJ.Capsular tension rings: who when and how who needs one?EyeNet Magazine October 2002; Accessed 1 Oct 2002. Available from:http:\/\/www.aao.org\/publications\/eyenet\/cataract\/cataract_oct.htm"}],"container-title":["Clinical &amp; Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1442-9071.2008.01726.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1442-9071.2008.01726.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T14:44:47Z","timestamp":1697381087000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1442-9071.2008.01726.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,4]]},"references-count":25,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2008,4]]}},"alternative-id":["10.1111\/j.1442-9071.2008.01726.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1442-9071.2008.01726.x","archive":["Portico"],"relation":{},"ISSN":["1442-6404","1442-9071"],"issn-type":[{"value":"1442-6404","type":"print"},{"value":"1442-9071","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,4]]},"assertion":[{"value":"2008-04-13","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}