{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T02:57:15Z","timestamp":1776653835945,"version":"3.51.2"},"reference-count":18,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2010,1,13]],"date-time":"2010-01-13T00:00:00Z","timestamp":1263340800000},"content-version":"vor","delay-in-days":12,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clinical Exper Ophthalmology"],"published-print":{"date-parts":[[2010,1]]},"abstract":"<jats:title>A<jats:sc>bstract<\/jats:sc><\/jats:title><jats:p><jats:bold>Background:\u2002<\/jats:bold> To report on 1\u2010year follow up of a series of 126 eyes implanted with a spherical implantable collamer lens (ICL).<\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold> Retrospective case note review of 126 eyes (68 patients) undergoing ICL placement by a single surgeon (TG) to correct preoperative mean spherical equivalents between +8.88 and \u221220.50\u2003D. Main outcome measures included uncorrected visual acuity (UCVA), refraction, best spectacle\u2010corrected VA, unaided binocular vision, adverse events, operative\/postoperative complications and patient symptoms.<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold> Complete data were available at 1\u2003year on 121 of the 126 eyes (65 out of 68 patients). At 12\u2003months 86% (104\/121) had postoperative UCVA better than or equal to preoperative best spectacle\u2010corrected VA, and 98% (118\/121) had UCVA within one line of preoperative best spectacle\u2010corrected VA. Ninety\u2010six per cent (116\/121) had postoperative UCVA of 6\/9 or better, and 100% had postoperative best\u2010corrected visual acuity of 6\/12 or better. Ninety\u2010eight per cent (64\/65) patients had unaided binocular vision at 1\u2003year of 6\/7.5 or better. Average myopia treated was \u22128.83\u2003D (116 patients), and average hyperopia +7.14\u2003D (10 patients). Two ICLs were replaced because of high vaulting; one eye had increased intraocular pressure that resolved with smaller ICL placement. Four patients had visually insignificant pigment deposits on the ICL at 3\/12, but no pigmentary glaucoma. Five patients noticed haloes around lights at night, none preventing driving.<\/jats:p><jats:p><jats:bold>Conclusions:\u2002<\/jats:bold> One\u2010year results from this study, the largest reported clinical investigation of the use of ICLs in New Zealand, support the safety, efficacy and predictability of ICL to treat both hyperopic and myopic spherical refractive errors.<\/jats:p>","DOI":"10.1111\/j.1442-9071.2010.02192.x","type":"journal-article","created":{"date-parts":[[2010,1,14]],"date-time":"2010-01-14T03:47:46Z","timestamp":1263440866000},"page":"21-26","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":33,"title":["Spherical implantable collamer lenses for myopia and hyperopia: 126 eyes with 1\u2010year follow up"],"prefix":"10.1111","volume":"38","author":[{"given":"Sandra A","family":"Rayner","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Riyaz","family":"Bhikoo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Trevor","family":"Gray","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2010,3,3]]},"reference":[{"key":"e_1_2_5_2_2","doi-asserted-by":"crossref","first-page":"282","DOI":"10.3928\/1081-597X-19980501-12","article-title":"Angle\u2010fixated anterior chamber phakic intraocular lens for myopia of \u22127 to \u221219\u2003diopters","volume":"14","author":"Baikoff G","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_5_3_2","first-page":"3","article-title":"Analysis of long term clinical and functional results of intraocular correction of high myopia","volume":"2","author":"Fyodorov SN","year":"1990","journal-title":"Ophthalmosurgery (Moscow)"},{"key":"e_1_2_5_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80486-5"},{"key":"e_1_2_5_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(98)80254-X"},{"key":"e_1_2_5_6_2","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1016\/S0886-3350(99)00417-4","article-title":"Phakic posterior chamber lenses for high myopia: functional and anatomical outcomes","volume":"26","author":"Arne JL","year":"2000","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_5_7_2","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1016\/S0886-3350(00)00759-8","article-title":"Implantable contact lens for moderate to high myopia: short\u2010term follow\u2010up of 2 models","volume":"27","author":"Gonvers M","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_5_8_2","doi-asserted-by":"crossref","first-page":"32","DOI":"10.3928\/1081-597X-20010101-04","article-title":"Posterior chamber phakic intraocular lenses to correct high myopia: a comparative study between Staar and Adatomed models","volume":"17","author":"Menezo JL","year":"2001","journal-title":"J Refract Surg"},{"key":"e_1_2_5_9_2","first-page":"415","article-title":"Posterior chamber collamer phakic intraocular lens for myopia and hyperopia","volume":"15","author":"Pesando PM","year":"1999","journal-title":"J Refract Surg"},{"key":"e_1_2_5_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(96)80007-1"},{"key":"e_1_2_5_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00011-5"},{"key":"e_1_2_5_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)80139-4"},{"key":"e_1_2_5_13_2","doi-asserted-by":"crossref","first-page":"840","DOI":"10.3928\/1081597X-20081001-12","article-title":"Phakic toric implantable collamer lens implantation for the correction of high myopic astigmatism in eyes with keratoconus","volume":"24","author":"Kamiya K","year":"2008","journal-title":"J Refract Surg"},{"key":"e_1_2_5_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01210-5"},{"key":"e_1_2_5_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2003.09.047"},{"key":"e_1_2_5_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01771-2"},{"key":"e_1_2_5_17_2","doi-asserted-by":"crossref","first-page":"1661","DOI":"10.1016\/S0886-3350(98)80361-1","article-title":"Cataract formation after posterior chamber phakic intraocular lens implantation","volume":"24","author":"Trindade F","year":"1999","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_5_18_2","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1016\/S0886-3350(99)00117-0","article-title":"Corneal perforation during laser in situ keratomileusis","volume":"25","author":"Joo CK","year":"1999","journal-title":"J Cataract Refract Surg"},{"key":"e_1_2_5_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.04.033"}],"container-title":["Clinical &amp; Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1442-9071.2010.02192.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1442-9071.2010.02192.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,31]],"date-time":"2023-10-31T03:26:43Z","timestamp":1698722803000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1442-9071.2010.02192.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,1]]},"references-count":18,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2010,1]]}},"alternative-id":["10.1111\/j.1442-9071.2010.02192.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1442-9071.2010.02192.x","archive":["Portico"],"relation":{},"ISSN":["1442-6404","1442-9071"],"issn-type":[{"value":"1442-6404","type":"print"},{"value":"1442-9071","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,1]]},"assertion":[{"value":"2010-03-03","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}