{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T04:29:16Z","timestamp":1793852956482,"version":"4.6.1"},"reference-count":19,"publisher":"Informa UK Limited","issue":"2","license":[{"start":{"date-parts":[[2015,9,1]],"date-time":"2015-09-01T00:00:00Z","timestamp":1441065600000},"content-version":"tdm","delay-in-days":3471,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clinical and Experimental Optometry"],"published-print":{"date-parts":[[2006,3]]},"DOI":"10.1111\/j.1444-0938.2006.00015.x","type":"journal-article","created":{"date-parts":[[2007,6,19]],"date-time":"2007-06-19T09:42:54Z","timestamp":1182246174000},"page":"73-80","source":"Crossref","is-referenced-by-count":107,"title":["The new Richmond HRR pseudoisochromatic test for colour vision is better than the Ishihara test"],"prefix":"10.1080","volume":"89","author":[{"given":"Barry L","family":"Cole","sequence":"first","affiliation":[{"name":"Department of Optometry and Vision Sciences, The University of Melbourne"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ka\u2010yee","family":"Lian","sequence":"additional","affiliation":[{"name":"Clinical Vision Research Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carol","family":"Lakkis","sequence":"additional","affiliation":[{"name":"Melbourne Optometry Clinic, Victorian College of Optometry"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"301","published-online":{"date-parts":[[2021,4,15]]},"reference":[{"key":"e_1_3_1_2_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSA.44.000509"},{"key":"e_1_3_1_3_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1956.00930040744013"},{"key":"e_1_3_1_4_1","first-page":"298","article-title":"Quantitative diagnosis of defective color vision. A comparative evaluation of the Ishihara test, the Farnsworth dichotomous test and the Hardy\u2010Rand\u2010Rittler polychromatic plates","volume":"51","author":"Crone RA","year":"1961","unstructured":"Crone RA. Quantitative diagnosis of defective color vision. A comparative evaluation of the Ishihara test, the Farnsworth dichotomous test and the Hardy\u2010Rand\u2010Rittler polychromatic plates. Am J Ophthalmol 1961; 51: 298\u2013305.","journal-title":"Am J Ophthalmol"},{"key":"e_1_3_1_5_1","first-page":"113","article-title":"Misuse of the Ishihara test for colour blindness","volume":"20","author":"Cole BL","year":"1963","unstructured":"Cole BL. Misuse of the Ishihara test for colour blindness. Br J Physiol Optics 1963; 20: 113\u2013118.","journal-title":"Br J Physiol Optics"},{"key":"e_1_3_1_6_1","first-page":"56","article-title":"Comments on some colour vision tests and their use for selection","volume":"47","author":"Cole BL","year":"1964","unstructured":"Cole BL. Comments on some colour vision tests and their use for selection. Aust J Optom 1964; 47: 56\u201364.","journal-title":"Aust J Optom"},{"key":"e_1_3_1_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-195904000-00001"},{"key":"e_1_3_1_8_1","doi-asserted-by":"publisher","DOI":"10.1017\/S0952523804213475"},{"key":"e_1_3_1_9_1","doi-asserted-by":"publisher","DOI":"10.1017\/S0952523804213463"},{"key":"e_1_3_1_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.1997.865.x"},{"key":"e_1_3_1_11_1","first-page":"176","article-title":"Tests for color deficiency based on the pseudoisochromatic principle","volume":"100","author":"Sloan LL","year":"1956","unstructured":"Sloan LL, Habel A. Tests for color deficiency based on the pseudoisochromatic principle. Arch Ophthalmol 1956; 100: 176\u2013182.","journal-title":"Arch Ophthalmol"},{"key":"e_1_3_1_12_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.42.6.355"},{"key":"e_1_3_1_13_1","unstructured":"Vingrys AJ. An analysis of colour vision standards in the transport industry. PhD thesis. The University of Melbourne: 1984."},{"key":"e_1_3_1_14_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSA.33.000568"},{"key":"e_1_3_1_15_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSA.42.000951"},{"key":"e_1_3_1_16_1","first-page":"1","article-title":"Effects of reduced illumination on the results obtained with some diagnostic colour vision tests in subjects with congenital red\u2010green defects","volume":"142","author":"Aarnisalo E","year":"1980","unstructured":"Aarnisalo E. Effects of reduced illumination on the results obtained with some diagnostic colour vision tests in subjects with congenital red\u2010green defects. Acta Ophthalmol Scand Suppl 1980; 142: 1\u201366.","journal-title":"Acta Ophthalmol Scand Suppl"},{"key":"e_1_3_1_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-94-011-1856-9_8"},{"key":"e_1_3_1_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.1992.tb00615.x"},{"key":"e_1_3_1_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(98)00119-9"},{"key":"e_1_3_1_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.2003.tb03109.x"}],"container-title":["Clinical and Experimental Optometry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1444-0938.2006.00015.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.tandfonline.com\/doi\/pdf\/10.1111\/j.1444-0938.2006.00015.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T03:33:50Z","timestamp":1772768030000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.tandfonline.com\/doi\/full\/10.1111\/j.1444-0938.2006.00015.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,3]]},"references-count":19,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2006,3]]}},"alternative-id":["10.1111\/j.1444-0938.2006.00015.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1444-0938.2006.00015.x","relation":{},"ISSN":["0816-4622","1444-0938"],"issn-type":[{"value":"0816-4622","type":"print"},{"value":"1444-0938","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,3]]}}}