{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,1,26]],"date-time":"2025-01-26T05:53:03Z","timestamp":1737870783916,"version":"3.33.0"},"reference-count":16,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2008,1,21]],"date-time":"2008-01-21T00:00:00Z","timestamp":1200873600000},"content-version":"vor","delay-in-days":9182,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Australian and New Zealand Journal of Surgery"],"published-print":{"date-parts":[[1982,12]]},"abstract":"<jats:p>Cuff impedance plethysmography has been performed on 120 patients undergoing total hip replacement surgery, all of whom have had venography. The low incidence of thrombosis (17.5%) precluded any accurate data on sensitivity, but specificity was 85%, positive accuracy 48%, negative<jats:italic>accuracy<\/jats:italic>92% and validity 82%. There was a high false positive rate in the first postoperative week (40% of 25 negative venograms). The technique is of value for the exclusion of thrombi in such patients after the eighth postoperative day. Venography will still be required for the positive identification of thrombi in any research protocol.<\/jats:p>","DOI":"10.1111\/j.1445-2197.1982.tb06113.x","type":"journal-article","created":{"date-parts":[[2008,1,21]],"date-time":"2008-01-21T11:54:15Z","timestamp":1200916455000},"page":"569-572","source":"Crossref","is-referenced-by-count":1,"title":["<b>THE DETECTION OF DEEP VENOUS THROMBOSIS BY IMPEDANCE PLETHYSMOGRAPHY IN HIP SURGERY PATIENTS<\/b>"],"prefix":"10.1111","volume":"52","author":[{"given":"D. H.","family":"GRAY","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"CHERIE E. J.","family":"MACKIE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2008,1,21]]},"reference":[{"key":"e_1_2_1_2_2","first-page":"317","article-title":"Advances in the diagnosis of venous thrombosis","volume":"1978","author":"GD QURESHI","year":"1978","journal-title":"Prog Clin Pathol"},{"key":"e_1_2_1_3_2","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1002\/bjs.1800650909","article-title":"The fibrinogen uptake test after hip surgery","volume":"1978","author":"JR LOUDON","year":"1978","journal-title":"Br J Surg."},{"key":"e_1_2_1_4_2","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1001\/archinte.1979.03630390014009","article-title":"The limited utility of fibrinogen 125I leg scanning.","volume":"1979","author":"RD SAUTTER","year":"1979","journal-title":"Arch Int Med."},{"key":"e_1_2_1_5_2","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1136\/bmj.2.6081.223","article-title":"Femoral vein thrombosis and total hip replacement","volume":"1977","author":"JD STAMATAKIS","year":"1977","journal-title":"Br Med J"},{"key":"e_1_2_1_6_2","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1097\/00000658-198002000-00013","article-title":"Prophylaxis of venous thromboembolism","volume":"1980","author":"EW SALZMAN","year":"1980","journal-title":"Ann Surg."},{"key":"e_1_2_1_7_2","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1259\/0007-1285-52-616-289","article-title":"Radionuclide venography in the management of proximal venous occlusion. A comparison with X\u2010ray contrast venography","volume":"1979","author":"PG BENTLEY","year":"1979","journal-title":"Br J Radiol."},{"key":"e_1_2_1_8_2","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/0002-9610(79)90371-4","article-title":"Reliability of doppler ultrasound in the diagnosis of acute venous thrombosis both above and below the knee","volume":"1979","author":"DS SUMNER","year":"1979","journal-title":"Am J Surg."},{"key":"e_1_2_1_9_2","first-page":"20","article-title":"Diagnosis of occult deep vein thrombosis by a noninvasive bedside technique","volume":"1971","author":"HB WHEELER","year":"1971","journal-title":"Surgery"},{"key":"e_1_2_1_10_2","doi-asserted-by":"crossref","first-page":"696","DOI":"10.1161\/01.CIR.53.4.696","article-title":"Impedance plethysmography using the occlusive cuff technique in the diagnosis of venous thrombosis","volume":"1976","author":"R HULL","year":"1976","journal-title":"Circulation"},{"key":"e_1_2_1_11_2","doi-asserted-by":"crossref","first-page":"1214","DOI":"10.1016\/0002-9149(79)90156-5","article-title":"New Developments in the detection and prevention of venous thromboembolism","volume":"1979","author":"AA SASAHARA","year":"1979","journal-title":"Am J Cardiol"},{"key":"e_1_2_1_12_2","doi-asserted-by":"crossref","first-page":"939","DOI":"10.2106\/00004623-197658070-00008","article-title":"Cuff\u2010impedance phlebography and 125I\u2010fibrinogen scanning versus roentgenographic phlebography for diagnosis of thrombophlebitis following hip surgery.","volume":"58","author":"WH HARRIS","year":"1976","journal-title":"J Bone JtSurg"},{"key":"e_1_2_1_13_2","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1002\/bjs.1800630520","article-title":"Impedance plethysmography: evaluation of a simplified system of electrodes for the measurement of blood flow in the lower limb","volume":"1976","author":"IG SCHRAIBMAN","year":"1976","journal-title":"Br J Surg."},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9610(78)90222-2"},{"key":"e_1_2_1_15_2","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1055\/s-0038-1646793","article-title":"Diagnosis of venous thrombosis.","volume":"41","author":"HIRSH J.","year":"1979","journal-title":"Thrombos and Haemostas."},{"key":"e_1_2_1_16_2","doi-asserted-by":"crossref","first-page":"12","DOI":"10.7326\/0003-4819-94-1-12","article-title":"Replacement of venography in suspected venous thrombosis by impedance plethysmography and 125I\u2010fibrinogen leg scanning.","volume":"1981","author":"R HULL","year":"1981","journal-title":"Ann Int Med."},{"key":"e_1_2_1_17_2","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/0002-9610(78)90032-6","article-title":"Screening for lower extremity deep venous thrombosis. An improved plethysmographic and doppler approach,","volume":"1978","author":"TJ LEPORE","year":"1978","journal-title":"AM J Surg."}],"container-title":["Australian and New Zealand Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1445-2197.1982.tb06113.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1445-2197.1982.tb06113.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,25]],"date-time":"2025-01-25T22:49:10Z","timestamp":1737845350000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1445-2197.1982.tb06113.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1982,12]]},"references-count":16,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1982,12]]}},"alternative-id":["10.1111\/j.1445-2197.1982.tb06113.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1445-2197.1982.tb06113.x","archive":["Portico"],"relation":{},"ISSN":["0004-8682"],"issn-type":[{"type":"print","value":"0004-8682"}],"subject":[],"published":{"date-parts":[[1982,12]]}}}