{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,6,20]],"date-time":"2024-06-20T11:56:35Z","timestamp":1718884595457},"reference-count":40,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2012,10,4]],"date-time":"2012-10-04T00:00:00Z","timestamp":1349308800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["ANZ Journal of Surgery"],"published-print":{"date-parts":[[2013,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>A peripheral intravenous device (<jats:styled-content style=\"fixed-case\">PIVD<\/jats:styled-content>) provides venous access for the administration of medications, blood products and fluids. They can be associated with a risk of infection and other complications, which have prompted the development of evidence\u2010based guidelines for their use at the <jats:styled-content style=\"fixed-case\">R<\/jats:styled-content>oyal <jats:styled-content style=\"fixed-case\">A<\/jats:styled-content>delaide <jats:styled-content style=\"fixed-case\">H<\/jats:styled-content>ospital (<jats:styled-content style=\"fixed-case\">RAH<\/jats:styled-content>). A previous audit performed at the <jats:styled-content style=\"fixed-case\">RAH<\/jats:styled-content> found unsatisfactory compliance with these guidelines across a group of wards. The <jats:styled-content style=\"fixed-case\">B<\/jats:styled-content>urns <jats:styled-content style=\"fixed-case\">U<\/jats:styled-content>nit performed poorly compared with other wards, but the reasons for this were not explored.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>A repeat audit was performed for all <jats:styled-content style=\"fixed-case\">PIVD<\/jats:styled-content>s in the <jats:styled-content style=\"fixed-case\">B<\/jats:styled-content>urns <jats:styled-content style=\"fixed-case\">U<\/jats:styled-content>nit over a 3\u2010week period and compliance with the <jats:styled-content style=\"fixed-case\">PIVD<\/jats:styled-content> safety guidelines was assessed. Factors influencing compliance were investigated and the evidence behind the guidelines was reviewed.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Overall compliance with the seven safety criteria was 71%. Poorest compliance was for documentation of insertion date, which has implications for scheduling <jats:styled-content style=\"fixed-case\">PIVD<\/jats:styled-content> replacement.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The guidelines are largely evidence\u2010based; however, not all of them are feasible for all patients within a hospital. The <jats:styled-content style=\"fixed-case\">B<\/jats:styled-content>urns <jats:styled-content style=\"fixed-case\">U<\/jats:styled-content>nit had an overall compliance rate of 71%. Auditing of individual wards is not effective in assessing those wards' compliance with the guidelines as many <jats:styled-content style=\"fixed-case\">PIVD<\/jats:styled-content>s are inserted in other locations in the hospital. For compliance to improve, other areas of the hospital where <jats:styled-content style=\"fixed-case\">PIVD<\/jats:styled-content>s are inserted need to be targeted.<\/jats:p><\/jats:sec>","DOI":"10.1111\/j.1445-2197.2012.06281.x","type":"journal-article","created":{"date-parts":[[2012,10,5]],"date-time":"2012-10-05T00:37:15Z","timestamp":1349397435000},"page":"764-768","update-policy":"http:\/\/dx.doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Safe and correct use of peripheral intravenous devices"],"prefix":"10.1111","volume":"83","author":[{"given":"Taisa","family":"Dorniak\u2010Wall","sequence":"first","affiliation":[{"name":"Medical School University of Adelaide  Adelaide South Australia Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laura","family":"Rudaks","sequence":"additional","affiliation":[{"name":"Medical School University of Adelaide  Adelaide South Australia Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicholas S.","family":"Solanki","sequence":"additional","affiliation":[{"name":"Burns Unit Royal Adelaide Hospital  Adelaide South Australia Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"Greenwood","sequence":"additional","affiliation":[{"name":"Burns Unit Royal Adelaide Hospital  Adelaide South Australia Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2012,10,4]]},"reference":[{"key":"e_1_2_6_2_1","first-page":"364","volume-title":"Roberts: Clinical Procedures in Emergency Medicine","author":"Liu SW","year":"2009"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.7748\/ns2006.08.20.49.49.c4484"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.a339"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1086\/501893"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1001\/archinte.158.2.151"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.3126\/kumj.v6i4.1732"},{"key":"e_1_2_6_8_1","doi-asserted-by":"crossref","first-page":"1191","DOI":"10.1001\/archinte.1984.00350180111017","article-title":"Intravenous therapy team and peripheral venous catheter\u2010associated complications","volume":"144","author":"Tomford J","year":"1984","journal-title":"Arch. Intern. Med."},{"key":"e_1_2_6_9_1","first-page":"1305","article-title":"I.v.\u2010related phlebitis, complications and length of hospital stay","volume":"7","author":"Campbell L.","year":"1998","journal-title":"Br. J. Nurs."},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-116-9-737"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.lpm.2008.03.017"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.a630"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9343(02)01163-4"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.5694\/j.1326-5377.2002.tb04412.x"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.JTN.0000327326.83276.ce"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijnurstu.2006.02.003"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.NAN.0000308544.67744.50"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199210083271505"},{"key":"e_1_2_6_19_1","volume-title":"Standards for Infusion Therapy","author":"Royal College of Nursing","year":"2005"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.12968\/bjon.2007.16.5.22998"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2648.1993.18060963.x"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1136\/ebn.8.1.8"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhin.2009.03.009"},{"issue":"10","key":"e_1_2_6_24_1","first-page":"s35","article-title":"Guidelines for the prevention of intravascular catheter\u2010related infections. Centers for Disease Control and Prevention","volume":"51","author":"O'Grady NP","year":"2002","journal-title":"MMWR. Morb. Mortal. Wkly Rep"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0196-6553(96)90058-9"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-114-10-845"},{"key":"e_1_2_6_27_1","first-page":"1","volume-title":"Burns of the Upper Extremity","author":"Pruitt BA","year":"1976"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.burns.2007.03.015"},{"key":"e_1_2_6_29_1","first-page":"121","article-title":"Clinical evaluation of chemical assault burns and occupational injuries: a 20 year study at a single burn center","volume":"23","author":"Lin C","year":"2011","journal-title":"Wounds"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1080\/078538902321012360"},{"key":"e_1_2_6_31_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006534-200006000-00028"},{"key":"e_1_2_6_32_1","first-page":"201","article-title":"Impact of dressing materials on central venous catheter infection rates","volume":"20","author":"Treston\u2010Aurand J","year":"1997","journal-title":"J. Intraven. Nurs."},{"key":"e_1_2_6_33_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.0309-2402.2003.02852.x"},{"key":"e_1_2_6_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/0732-8893(84)90064-6"},{"key":"e_1_2_6_35_1","doi-asserted-by":"crossref","first-page":"2396","DOI":"10.1001\/jama.1987.03400170082027","article-title":"Evaluation of dressing regimens for prevention of infection with peripheral intravenous catheters","volume":"258","author":"Maki D","year":"1987","journal-title":"JAMA"},{"key":"e_1_2_6_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/0196-6553(88)90046-6"},{"key":"e_1_2_6_37_1","first-page":"253","article-title":"A randomized study comparing IV 3000 (transparent polyurethane dressing) to a dry gauze dressing for peripheral intravenous catheter sites","volume":"20","author":"Madeo M","year":"1997","journal-title":"J. Intraven. Nurs."},{"key":"e_1_2_6_38_1","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1016\/S0029-6465(22)00095-0","article-title":"The use of gauze versus transparent dressings for peripheral intravenous catheter sites","volume":"30","author":"Pettit D","year":"1995","journal-title":"Nurs. Clin. North Am."},{"key":"e_1_2_6_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/0195-6701(93)90015-R"},{"key":"e_1_2_6_40_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-199422110-00006"},{"key":"e_1_2_6_41_1","doi-asserted-by":"crossref","first-page":"2072","DOI":"10.1001\/jama.1992.03480150078041","article-title":"Transparent polyurethane film as an intravenous catheter dressing. A meta\u2010analysis of the infection risks","volume":"267","author":"Hoffmann K","year":"1992","journal-title":"JAMA"}],"container-title":["ANZ Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1445-2197.2012.06281.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1445-2197.2012.06281.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,5]],"date-time":"2023-10-05T05:35:17Z","timestamp":1696484117000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1445-2197.2012.06281.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,10,4]]},"references-count":40,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2013,10]]}},"alternative-id":["10.1111\/j.1445-2197.2012.06281.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1445-2197.2012.06281.x","archive":["Portico"],"relation":{},"ISSN":["1445-1433","1445-2197"],"issn-type":[{"value":"1445-1433","type":"print"},{"value":"1445-2197","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,10,4]]},"assertion":[{"value":"2012-08-27","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2012-10-04","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}