{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,25]],"date-time":"2025-10-25T18:59:31Z","timestamp":1761418771938},"reference-count":29,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2012,5,23]],"date-time":"2012-05-23T00:00:00Z","timestamp":1337731200000},"content-version":"vor","delay-in-days":22,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Internal Medicine Journal"],"published-print":{"date-parts":[[2012,5]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p><jats:bold>Background:\u2002<\/jats:bold> No long\u2010term data on implantable cardioverter\u2010defibrillators (ICDs) exist in Australasia.<\/jats:p><jats:p><jats:bold>Aims:\u2002<\/jats:bold> We examined all patients receiving a new ICD implant at Wellington Hospital between January 2001 and December 2005 to determine long\u2010term outcomes in this patient population.<\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold> Follow\u2010up data were collected and Kaplan\u2013Meier curves were constructed for survival and long\u2010term outcomes, and Cox proportional hazard model was used for calculation of hazard ratio.<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold> In the study period, 138 new ICDs were implanted, and the mean follow\u2010up time was 84 \u00b1 16 months. Patients were predominantly male (76%), 75% were European, 20% were Maori. Median age was 59\u2003years (range 16\u201380\u2003years). In 47% of patients, there was an ischaemic substrate. A secondary\u2010prevention indication was present in 77%. The 7\u2010year survival rate was 72%. No difference in mortality was observed between primary\u2010 and secondary\u2010prevention groups. The 7\u2010year appropriate therapy rate was 55%. The appropriate shock rate was greater in secondary prevention than in primary\u2010prevention patients was observed (hazard ratio = 2.11, 95% confidence interval 1.16\u20133.85, <jats:italic>P<\/jats:italic>= 0.01). Over the study period, inappropriate therapy rate was 25%. This was more common in patients with prior atrial fibrillation (hazard ratio = 3.57, 95% confidence interval 1.80\u20137.09, <jats:italic>P<\/jats:italic> &lt; 0.001). The median device longevity was 6.8\u2003years.<\/jats:p><jats:p><jats:bold>Conclusions:\u2002<\/jats:bold> This is the first long\u2010term follow\u2010up study of ICD patients in New Zealand. We observed a low mortality rate when compared with other published registries, but a similar rate of both appropriate and inappropriate shock therapy.<\/jats:p>","DOI":"10.1111\/j.1445-5994.2011.02710.x","type":"journal-article","created":{"date-parts":[[2011,12,29]],"date-time":"2011-12-29T18:14:19Z","timestamp":1325182459000},"page":"554-561","update-policy":"http:\/\/dx.doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Implantable cardioverter\u2010defibrillators: a long\u2010term view"],"prefix":"10.1111","volume":"42","author":[{"given":"D.","family":"Wilson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Shi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Harding","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N.","family":"Lever","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"Larsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2012,5,23]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"crossref","first-page":"1576","DOI":"10.1056\/NEJM199711273372202","article-title":"A comparison of antiarrhythmic\u2010drug therapy with implantable defibrillators in patients resuscitated from near\u2010fatal ventricular arrhythmias. The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators","volume":"337","author":"Anon","year":"1997","journal-title":"N Engl J Med"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.102.7.748"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199612263352601"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.101.11.1297"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa013474"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehm305"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2008.02.032"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-005-5834-1"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2008.05.058"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2010.1939"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000134957.51747.6E"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000150390.04704.B7"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa071098"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2008.12.023"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.110.940148"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2006.03.027"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1080\/14017430701762719"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2008.02222.x"},{"key":"e_1_2_7_20_2","first-page":"1023","article-title":"Over 10 years with an implantable cardioverter\u2010defibrillator \u2013 a long term follow\u2010up of 60 patients","volume":"68","author":"Sterlinski M","year":"2010","journal-title":"Kardiol Pol"},{"key":"e_1_2_7_21_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euq494"},{"key":"e_1_2_7_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2011.07.036"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2010.06.059"},{"key":"e_1_2_7_24_2","first-page":"76","article-title":"Use of implantable cardioverter defibrillators in the New Zealand context from 2000 to 2007","volume":"123","author":"Larsen PD","year":"2010","journal-title":"N Z Med J"},{"key":"e_1_2_7_25_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eur113"},{"key":"e_1_2_7_26_2","doi-asserted-by":"publisher","DOI":"10.1001\/archinternmed.2009.255"},{"key":"e_1_2_7_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2010.03.042"},{"key":"e_1_2_7_28_2","doi-asserted-by":"publisher","DOI":"10.2143\/AC.63.1.2025330"},{"key":"e_1_2_7_29_2","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eun240"},{"key":"e_1_2_7_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2009.09.013"}],"container-title":["Internal Medicine Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1445-5994.2011.02710.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1445-5994.2011.02710.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T01:36:35Z","timestamp":1697333795000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1445-5994.2011.02710.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,5]]},"references-count":29,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2012,5]]}},"alternative-id":["10.1111\/j.1445-5994.2011.02710.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1445-5994.2011.02710.x","archive":["Portico"],"relation":{},"ISSN":["1444-0903","1445-5994"],"issn-type":[{"value":"1444-0903","type":"print"},{"value":"1445-5994","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,5]]},"assertion":[{"value":"2012-05-23","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}