{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,18]],"date-time":"2026-04-18T00:05:06Z","timestamp":1776470706299,"version":"3.51.2"},"reference-count":14,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2005,4,11]],"date-time":"2005-04-11T00:00:00Z","timestamp":1113177600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pediatric Anesthesia"],"published-print":{"date-parts":[[2005,5]]},"abstract":"<jats:title>Summary<\/jats:title><jats:p><jats:bold>Background<\/jats:bold> :\u2002The aim of this study was to evaluate a new device for airway management in children: the laryngeal tube (LT<jats:sup>TM<\/jats:sup>).<\/jats:p><jats:p><jats:bold>Methods<\/jats:bold> :\u2002The LT<jats:sup>TM<\/jats:sup> is available in sizes S0\u2013S3 for pediatric anesthesia. This prospective open study included 70 children ASA 1. The local Ethics Committee approval and parental consent were collected. The primary criterion was the success rate for insertion and ventilation. Secondary criteria were additional maneuvers and incidents elicited from LT use.<\/jats:p><jats:p><jats:bold>Results<\/jats:bold> :\u2002Seventy children were included: S0\u2003=\u20035, S1\u2003=\u20038, S2\u2003=\u200336, and S3\u2003=\u200321. Insertion was successful: at the first attempt in 78.6%, second in 17.1%, and third or more in 4.3%. In 12% of cases it was not possible to successfully insert the LT and proceed to adequate ventilation. Failures were explained by: inability to obtain satisfying ventilation (<jats:italic>n<\/jats:italic>\u2003=\u20034), hypoxemia (<jats:italic>n<\/jats:italic>\u2003=\u20031), gastric insufflation (<jats:italic>n<\/jats:italic>\u2003=\u20036), cough (<jats:italic>n<\/jats:italic>\u2003=\u20031), and laryngospasm or stridor (<jats:italic>n<\/jats:italic>\u2003=\u20032), some with the same child. Minimal additional maneuvers for adequate ventilation were necessary in 35% of cases (all groups), but &lt;20% when considering only sizes 2 and 3. Moreover, after five cases, the anesthesiologists became more proficient at inserting the LT<jats:sup>TM<\/jats:sup> (respectively 73.3% failure before five cases vs 13% afterwards). Gastric insufflation occurred in eight cases (11.4%). Controlled ventilation was used in 30 children and peak inspiratory pressure was 19.2\u2003\u00b1\u20034\u2003cmH<jats:sub>2<\/jats:sub>O.<\/jats:p><jats:p><jats:bold>Conclusions<\/jats:bold> :\u2002The LT<jats:sup>TM<\/jats:sup> is not recommended for children &lt;10\u2003kg. Over 10\u2003kg, it provides a clear airway in most children, with a low rate of minimal additional maneuvers for sizes 2 and 3. The failure rate also decreases with the operator's training.<\/jats:p>","DOI":"10.1111\/j.1460-9592.2005.01469.x","type":"journal-article","created":{"date-parts":[[2005,4,11]],"date-time":"2005-04-11T17:17:23Z","timestamp":1113239843000},"page":"391-396","source":"Crossref","is-referenced-by-count":28,"title":["Clinical assessment of the laryngeal tube in pediatric anesthesia"],"prefix":"10.1111","volume":"15","author":[{"given":"PHILIPPE","family":"RICHEB\u00c9","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"FRAN\u00c7OIS","family":"SEMJEN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ANNE\u2010MARIE","family":"CROS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"PIERRE","family":"MAURETTE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2005,4,11]]},"reference":[{"key":"e_1_2_5_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000539-200005000-00042"},{"key":"e_1_2_5_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003643-200204000-00012"},{"key":"e_1_2_5_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0300-9572(02)00170-3"},{"key":"e_1_2_5_5_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2044.2000.01710.x"},{"key":"e_1_2_5_6_2","first-page":"1340","article-title":"Laryngeal tube: its use for controlled ventilation","volume":"50","author":"Asai T","year":"2001","journal-title":"Masui"},{"key":"e_1_2_5_7_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/89.5.729"},{"key":"e_1_2_5_8_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2044.2001.02230-11.x"},{"key":"e_1_2_5_9_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/70.1.25"},{"key":"e_1_2_5_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1996.tb12581.x"},{"key":"e_1_2_5_11_2","doi-asserted-by":"publisher","DOI":"10.1080\/10903120090941452"},{"key":"e_1_2_5_12_2","first-page":"332","article-title":"Application of the laryngeal mask in pediatric anesthesiology","volume":"42","author":"Lopez Gil T","year":"1995","journal-title":"Rev Esp Anesthesiol Reanim"},{"key":"e_1_2_5_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199605000-00037"},{"key":"e_1_2_5_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1996.tb14968.x"},{"key":"e_1_2_5_15_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2044.1998.00261.x"}],"container-title":["Pediatric Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1460-9592.2005.01469.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1460-9592.2005.01469.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,14]],"date-time":"2023-10-14T09:56:44Z","timestamp":1697277404000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1460-9592.2005.01469.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,4,11]]},"references-count":14,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2005,5]]}},"alternative-id":["10.1111\/j.1460-9592.2005.01469.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1460-9592.2005.01469.x","archive":["Portico"],"relation":{},"ISSN":["1155-5645","1460-9592"],"issn-type":[{"value":"1155-5645","type":"print"},{"value":"1460-9592","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,4,11]]}}}