{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,17]],"date-time":"2026-02-17T21:27:42Z","timestamp":1771363662135,"version":"3.50.1"},"reference-count":7,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2009,7,9]],"date-time":"2009-07-09T00:00:00Z","timestamp":1247097600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pediatric Anesthesia"],"published-print":{"date-parts":[[2009,8]]},"abstract":"<jats:title>Summary<\/jats:title><jats:p><jats:bold>Background:\u2002<\/jats:bold> High\u2010frequency oscillation ventilation (HFOV) is an accepted ventilatory mode for acute respiratory failure in neonates. As conventional mechanical ventilation, inspiratory gas humidification is essential. However, humidification during HFOV has not been clarified. In this bench study, we evaluated humidification during HFOV in the open circumstance of ICU. Our hypothesis is that humidification during HFOV is affected by circuit design and ventilatory settings.<\/jats:p><jats:p><jats:bold>Methods\/Materials:\u2002<\/jats:bold> We connected a ventilator with HFOV mode to a neonatal lung model that was placed in an infant incubator set at 37\u00b0C. We set a heated humidifier (Fisher &amp; Paykel) to obtain 37\u00b0C at the chamber outlet and 40\u00b0C at the distal temperature probe. We measured absolute humidity and temperature at the Y\u2010piece using a rapid\u2010response hygrometer. We evaluated two types of ventilator circuit: a circuit with inner heating wire and another with embedded heating element. In addition, we evaluated three lengths of the inspiratory limb, three stroke volumes, three frequencies, and three mean airway pressures.<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold> The circuit with embedded heating element provided significantly higher absolute humidity and temperature than one with inner heating wire. As an extended tube lacking a heating wire was shorter, absolute humidity and temperature became higher. In the circuit with inner heating wire, absolute humidity and temperature increased as stroke volume increased.<\/jats:p><jats:p><jats:bold>Conclusion:\u2002<\/jats:bold> Humidification during HFOV is affected by circuit design and ventilatory settings.<\/jats:p>","DOI":"10.1111\/j.1460-9592.2009.03068.x","type":"journal-article","created":{"date-parts":[[2009,7,10]],"date-time":"2009-07-10T04:53:09Z","timestamp":1247201589000},"page":"779-783","source":"Crossref","is-referenced-by-count":14,"title":["Humidification during high\u2010frequency oscillation ventilation is affected by ventilator circuit and ventilatory setting"],"prefix":"10.1111","volume":"19","author":[{"given":"YUSUKE","family":"CHIKATA","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"HIDEAKI","family":"IMANAKA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"YOSHIAKI","family":"ONISHI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MASAHIKO","family":"UETA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MASAJI","family":"NISHIMURA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2009,7,9]]},"reference":[{"key":"e_1_2_6_2_2","first-page":"887","article-title":"Humidification during mechanical ventilation","volume":"37","author":"AARC Clinical Guideline","year":"1992","journal-title":"Respir Care"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/s001340050995"},{"key":"e_1_2_6_4_2","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1152\/jappl.1983.54.2.331","article-title":"Respiratory heat and water exchange: physiological and clinical implications","volume":"54","author":"McFadden ER","year":"1983","journal-title":"J Appl Physiol"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1985.58.2.564"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-199103000-00019"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-199110000-00014"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.100.1.268"}],"container-title":["Pediatric Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1460-9592.2009.03068.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1460-9592.2009.03068.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,9]],"date-time":"2023-10-09T19:14:42Z","timestamp":1696878882000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1460-9592.2009.03068.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,7,9]]},"references-count":7,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2009,8]]}},"alternative-id":["10.1111\/j.1460-9592.2009.03068.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1460-9592.2009.03068.x","archive":["Portico"],"relation":{},"ISSN":["1155-5645","1460-9592"],"issn-type":[{"value":"1155-5645","type":"print"},{"value":"1460-9592","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,7,9]]}}}