{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T12:25:46Z","timestamp":1789388746951,"version":"build-2803163510"},"reference-count":18,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2011,6,21]],"date-time":"2011-06-21T00:00:00Z","timestamp":1308614400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pediatric Anesthesia"],"published-print":{"date-parts":[[2011,11]]},"abstract":"<jats:title>Summary<\/jats:title><jats:p><jats:bold>Background:\u2002<\/jats:bold> This crossover study compared fiber\u2010optic assessment of laryngeal mask airway (LMA) position in children using two LMA insertion techniques, i.e., standard and rotational.<\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold> Seventy\u2010eight ASA I children, aged 2.5\u2003months to 10\u2003years, undergoing elective cataract surgery were included in this study. LMA was inserted in random order using either standard or rotational technique, removed, and thereafter crossed over to alternate technique. Positioning of LMA was assessed using fiber\u2010optic bronchoscope with each technique. Change in the incidence of fiber\u2010optic assessment grades 1 and 2 between two insertion techniques was measured as the primary outcome. Secondary outcome measures studied were first\u2010attempt success rate, overall success rate, time for successful insertion, visual analogue scale for placement, complications, and maneuvers used to relieve airway obstruction.<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold> Incidence of fiber\u2010optic grades 1 and 2 was 61.5% with standard technique and increased to 92.3% with rotational technique (<jats:italic>P<\/jats:italic>\u2003&lt;\u20030.001, McNemar\u2019s test) (RR 3.0, 95% CI 2.2\u20134.2). Median (IQR) fiber\u2010optic grading was significantly better with rotational technique [2 (1\u20132)] as compared to standard technique [2 (2\u20133)], (<jats:italic>P<\/jats:italic>\u2003&lt;\u20030.001, Wilcoxon signed rank test). First\u2010attempt success rate was significantly higher (96.2%) with rotational technique compared with standard technique (80.7%) (<jats:italic>P<\/jats:italic>\u2003=\u20030.04, McNemar\u2019s test). Overall success rate (i.e., successful insertion with two attempts) was 100% with rotational technique compared with 89.7% with standard technique (<jats:italic>P<\/jats:italic>\u2003=\u20030.003, Fischer\u2019s exact test). Time for successful insertion and incidence of complications were significantly lesser with rotational technique.<\/jats:p><jats:p><jats:bold>Conclusion:\u2002<\/jats:bold> Rotational technique of LMA insertion in children is associated with better seating of LMA (as observed on fiber\u2010optic assessment) compared with the standard technique. Also, it is associated with higher success rate and lower incidence of complications.<\/jats:p>","DOI":"10.1111\/j.1460-9592.2011.03632.x","type":"journal-article","created":{"date-parts":[[2011,6,21]],"date-time":"2011-06-21T05:43:26Z","timestamp":1308635006000},"page":"1142-1147","source":"Crossref","is-referenced-by-count":14,"title":["Fiber\u2010optic assessment of LMA position in children: a randomized crossover comparison of two techniques"],"prefix":"10.1111","volume":"21","author":[{"given":"Babita","family":"Ghai","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jagat","family":"Ram","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeetinder K.","family":"Makkar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jyotsna","family":"Wig","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2011,6,21]]},"reference":[{"key":"e_1_2_5_2_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/55.8.801"},{"key":"e_1_2_5_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.2008.02434.x"},{"key":"e_1_2_5_4_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2002.00847.x"},{"key":"e_1_2_5_5_2","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X0102900512"},{"key":"e_1_2_5_6_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2003.01134.x"},{"key":"e_1_2_5_7_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2001.00749.x"},{"key":"e_1_2_5_8_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aei045"},{"key":"e_1_2_5_9_2","doi-asserted-by":"publisher","DOI":"10.1213\/01.ANE.0000152640.25078.90"},{"key":"e_1_2_5_10_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aeh238"},{"key":"e_1_2_5_11_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aei234"},{"key":"e_1_2_5_12_2","doi-asserted-by":"publisher","DOI":"10.1213\/00000539-199404000-00007"},{"key":"e_1_2_5_13_2","doi-asserted-by":"publisher","DOI":"10.1213\/01.ane.0000194300.56739.1a"},{"key":"e_1_2_5_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/ACO.0b013e3283294d06"},{"key":"e_1_2_5_15_2","volume-title":"The Intavent Laryngeal Mask Instruction Manual","author":"Brain AIJ","year":"1992"},{"key":"e_1_2_5_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1991.tb11693.x"},{"key":"e_1_2_5_17_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1996.tb14968.x"},{"key":"e_1_2_5_18_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2002.00887.x"},{"key":"e_1_2_5_19_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03014975"}],"container-title":["Pediatric Anesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1460-9592.2011.03632.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1460-9592.2011.03632.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,14]],"date-time":"2023-10-14T11:51:23Z","timestamp":1697284283000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1460-9592.2011.03632.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,6,21]]},"references-count":18,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2011,11]]}},"alternative-id":["10.1111\/j.1460-9592.2011.03632.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1460-9592.2011.03632.x","archive":["Portico"],"relation":{},"ISSN":["1155-5645","1460-9592"],"issn-type":[{"value":"1155-5645","type":"print"},{"value":"1460-9592","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,6,21]]}}}