{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T20:52:03Z","timestamp":1771879923132,"version":"3.50.1"},"reference-count":30,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2003,12,22]],"date-time":"2003-12-22T00:00:00Z","timestamp":1072051200000},"content-version":"vor","delay-in-days":661,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["obgyn.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["BJOG"],"published-print":{"date-parts":[[2002,3]]},"abstract":"<jats:p><jats:bold>Objective\n\t\t\t\t\t<\/jats:bold> To compare urethral pressure profilometry measurements using microtip transducer and double\u2010lumen perfusion catheters.<\/jats:p><jats:p><jats:bold>Design\n\t\t\t\t\t<\/jats:bold> Prospective study.<\/jats:p><jats:p><jats:bold>Setting\n\t\t\t\t\t<\/jats:bold> Tertiary referral urogynaecology unit.<\/jats:p><jats:p><jats:bold>Sample\n\t\t\t\t\t<\/jats:bold> Three hundred and ninety two non\u2010pregnant women with various lower urinary tract symptoms.<\/jats:p><jats:p><jats:bold>Methods\n\t\t\t\t\t<\/jats:bold> Multichannel urodynamic investigations were performed using double\u2010lumen perfusion catheters with external pressure transducers in 392 women. For those 301 (76.8%) diagnosed as having genuine stress incontinence, an investigation with microtip transducers followed. For data analysis, a mixed\u2010effects model was used to evaluate changes in the urethral profilometry and an approach proposed by Bland and Altman was applied to access agreement between the two techniques.<\/jats:p><jats:p><jats:bold>Results\n\t\t\t\t\t<\/jats:bold> Of the 301 women with genuine stress incontinence, 272 were eligible for this study. In resting status, the differences between the two techniques were statistically significant (<jats:styled-content>48.9cm H<jats:sub>2<\/jats:sub>O <jats:italic>vs<\/jats:italic> 73.4cm H<jats:sub>2<\/jats:sub>O, <jats:italic>P<\/jats:italic>= 0.0001<\/jats:styled-content>) after adjusting for age. Moreover, the agreement study also confirmed that these two techniques do not agree sufficiently.<\/jats:p><jats:p><jats:bold>Conclusion\n\t\t\t\t\t<\/jats:bold> Maximum urethral closure pressure obtained from the double\u2010lumen catheter was significantly higher than that obtained from the microtip catheter. Use of the double\u2010lumen catheter for the measurement of maximum urethral closure pressure can be considered a reliable technique since its reproducibility is as good as that of the microtip catheter. Therefore, the diagnosis of \u2018low pressure urethra\u2019 will be different between the two techniques.<\/jats:p>","DOI":"10.1111\/j.1471-0528.2002.01001.x","type":"journal-article","created":{"date-parts":[[2003,12,22]],"date-time":"2003-12-22T16:25:19Z","timestamp":1072110319000},"page":"322-326","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":26,"title":["A comparison of urethral pressure profilometry using microtip and double\u2010lumen perfusion catheters in women with genuine stress incontinence"],"prefix":"10.1111","volume":"109","author":[{"given":"Alex C.","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Min\u2010Chi","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2003,12,22]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/0029-7844(95)00014-I"},{"key":"e_1_2_6_3_2","first-page":"399","article-title":"The low pressure urethra as a factor in failed retropubic urethropexy","volume":"69","author":"Sand PK","year":"1987","journal-title":"Obstet Gynecol"},{"key":"e_1_2_6_4_2","first-page":"351","article-title":"Urodynamic findings in patients after failure of stress incontinence operations","volume":"78","author":"McGuire EJ","year":"1981","journal-title":"Prog Clin Biol Res"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1471-0528.1983.tb06764.x"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.3109\/00016347509156772"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1002\/nau.1930080511"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5347(17)51425-1"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1464-410X.1978.tb02762.x"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1464-410X.1974.tb03834.x"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9378(89)90471-7"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5347(17)56874-3"},{"key":"e_1_2_6_13_2","first-page":"188","article-title":"Predicting intrinsic urethral sphincter dysfunction in women with stress urinary incontinence","volume":"84","author":"Horbach NS","year":"1994","journal-title":"Obstet Gynecol"},{"key":"e_1_2_6_14_2","first-page":"511","volume-title":"Fundamentals of Biostatistics","author":"Rosner B","year":"2000"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1002\/sim.4780090402"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5347(17)58132-X"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5347(17)54449-3"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9378(00)70487-X"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1007\/s001920050065"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9378(96)70140-0"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9378(97)70069-3"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5347(17)35806-8"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9378(95)90281-3"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1464-410X.1969.tb09925.x"},{"key":"e_1_2_6_26_2","first-page":"115","volume-title":"Urogynecology and Urodynamics Theory and Practice","author":"Jensen JK","year":"1996"},{"key":"e_1_2_6_27_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02477303"},{"key":"e_1_2_6_28_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF00257370"},{"key":"e_1_2_6_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5347(17)57234-1"},{"key":"e_1_2_6_30_2","doi-asserted-by":"publisher","DOI":"10.3109\/00016347709155025"},{"key":"e_1_2_6_31_2","doi-asserted-by":"publisher","DOI":"10.3109\/00016348009154090"}],"container-title":["BJOG: An International Journal of Obstetrics &amp; Gynaecology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1471-0528.2002.01001.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/obgyn.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1471-0528.2002.01001.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,17]],"date-time":"2023-10-17T17:42:29Z","timestamp":1697564549000},"score":1,"resource":{"primary":{"URL":"https:\/\/obgyn.onlinelibrary.wiley.com\/doi\/10.1111\/j.1471-0528.2002.01001.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002,3]]},"references-count":30,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2002,3]]}},"alternative-id":["10.1111\/j.1471-0528.2002.01001.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1471-0528.2002.01001.x","archive":["Portico"],"relation":{},"ISSN":["1470-0328","1471-0528"],"issn-type":[{"value":"1470-0328","type":"print"},{"value":"1471-0528","type":"electronic"}],"subject":[],"published":{"date-parts":[[2002,3]]},"assertion":[{"value":"2003-12-22","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}