{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T13:49:18Z","timestamp":1761918558669},"reference-count":21,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2003,12,22]],"date-time":"2003-12-22T00:00:00Z","timestamp":1072051200000},"content-version":"vor","delay-in-days":447,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["obgyn.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["BJOG"],"published-print":{"date-parts":[[2002,10]]},"abstract":"<jats:p><jats:bold>Objective\n\t\t\t\t\t<\/jats:bold> To evaluate the accuracy of the OMRON\u2010MIT inflationary oscillometric device for blood pressure measurement in pregnancy and pre\u2010eclampsia.<\/jats:p><jats:p><jats:bold>Design\n\t\t\t\t\t<\/jats:bold> Prospective observational study, using validation methods recommended by the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI).<\/jats:p><jats:p><jats:bold>Settings\n\t\t\t\t\t<\/jats:bold> Antenatal clinics and ward, Guy's Hospital, London.<\/jats:p><jats:p><jats:bold>Population\n\t\t\t\t\t<\/jats:bold> Normotensive pregnant women and those diagnosed with pre\u2010eclampsia according to the definition of the International Society for the Study of Hypertension in Pregnancy.<\/jats:p><jats:p><jats:bold>Methods\n\t\t\t\t\t<\/jats:bold> Validation according to BHS protocol.<\/jats:p><jats:p><jats:bold>Main outcome measures\n\t\t\t\t\t<\/jats:bold> Proportion of readings within 5, 10 and 15 mmHg (absolute differences) between the automated device and two trained, blinded observers, according to the BHS and AAMI criteria.<\/jats:p><jats:p><jats:bold>Results\n\t\t\t\t\t<\/jats:bold> The OMRON\u2010MIT achieved an overall BHS grade B for systolic and grade A for diastolic blood pressure measurement in both pregnancy and pre\u2010eclampsia. The mean (SD) differences between the standard and the test device were \u22125 (7) mmHg for systolic and 2 (6) mmHg for diastolic blood pressure in pregnancy and \u22124 (6) mmHg for systolic and 2 (7) mmHg for diastolic blood pressure in pre\u2010eclampsia. This device therefore fulfils the AAMI criteria.<\/jats:p><jats:p><jats:bold>Conclusion\n\t\t\t\t\t<\/jats:bold> The OMRON\u2010MIT is the only automated oscillometric device that has proven to be accurate for blood pressure measurement in pre\u2010eclampsia according to the BHS protocol in pregnancy. Inflationary oscillometry may correct the error associated with oscillometric devices in pre\u2010eclampsia.<\/jats:p>","DOI":"10.1111\/j.1471-0528.2002.01487.x","type":"journal-article","created":{"date-parts":[[2003,12,22]],"date-time":"2003-12-22T15:24:20Z","timestamp":1072106660000},"page":"1143-1147","update-policy":"http:\/\/dx.doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":27,"title":["Inflationary oscillometry provides accurate measurement of blood pressure in pre\u2010eclampsia"],"prefix":"10.1111","volume":"109","author":[{"given":"Moneli","family":"Golara","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amanda","family":"Benedict","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Clare","family":"Jones","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manjit","family":"Randhawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lucilla","family":"Poston","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew H.","family":"Shennan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2003,12,22]]},"reference":[{"key":"e_1_2_5_2_2","unstructured":"Report on confidential enquiries into maternal deaths in the United Kingdom 1991\u20131993. London :Her Majesty's Stationary Office 1996."},{"key":"e_1_2_5_3_2","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1067\/mob.2000.107928","article-title":"Report of the National High Blood Pressure Education Program Working Group on high blood pressure in pregnancy","volume":"183","author":"NHBPEP Working Group on High Blood Pressure in Pregnancy","year":"2000","journal-title":"Am J Obstet Gynecol"},{"key":"e_1_2_5_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0950-3552(05)80214-7"},{"key":"e_1_2_5_5_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.301.6762.1198"},{"key":"e_1_2_5_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1471-0528.1991.tb13386.x"},{"key":"e_1_2_5_7_2","doi-asserted-by":"publisher","DOI":"10.5694\/j.1326-5377.1992.tb139782.x"},{"key":"e_1_2_5_8_2","first-page":"933","article-title":"Will mercury manometers soon be obsolete?","volume":"9","author":"O'Brien E","year":"1995","journal-title":"J Hum Hypertens"},{"issue":"2","key":"e_1_2_5_9_2","first-page":"S43","article-title":"The British Hypertension Society protocol for the evaluation of blood pressure measuring devices","volume":"11","author":"O'Brien E","year":"1993","journal-title":"J Hypertens"},{"key":"e_1_2_5_10_2","unstructured":"American National Standard for Electronic or Automated Sphygmomanometers.Arlington (Virginia): Association for the Advancement of Medical Instrumentation 1987 25 p."},{"key":"e_1_2_5_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1471-0528.1996.tb09671.x"},{"key":"e_1_2_5_12_2","doi-asserted-by":"publisher","DOI":"10.3109\/10641959609009592"},{"key":"e_1_2_5_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9378(99)70109-2"},{"key":"e_1_2_5_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1471-0528.1997.tb11467.x"},{"key":"e_1_2_5_15_2","first-page":"151","article-title":"The first accurate hospital blood pressure device performs poorly in pre\u2010eclampsia","volume":"19","author":"Jones CR","year":"2000","journal-title":"Hypertens Pregnancy"},{"key":"e_1_2_5_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1471-0528.1994.tb13013.x"},{"key":"e_1_2_5_17_2","doi-asserted-by":"publisher","DOI":"10.3109\/10641959709031636"},{"key":"e_1_2_5_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9378(88)90090-7"},{"key":"e_1_2_5_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"e_1_2_5_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9378(94)70146-6"},{"key":"e_1_2_5_21_2","doi-asserted-by":"publisher","DOI":"10.1053\/beog.1999.0006"},{"key":"e_1_2_5_22_2","unstructured":"HibbardJU KorcarzCGiardetNendaz G ShroffS LindheimerM LangR.Arterial circulation in pregnancy complicated by hypertension [abstract].11th World Congress of the International Society for the Study of Hypertension in Pregnancy Japan 1998:OS13\u20104."}],"container-title":["BJOG: An International Journal of Obstetrics &amp; Gynaecology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1471-0528.2002.01487.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/obgyn.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1471-0528.2002.01487.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,17]],"date-time":"2023-10-17T16:55:06Z","timestamp":1697561706000},"score":1,"resource":{"primary":{"URL":"https:\/\/obgyn.onlinelibrary.wiley.com\/doi\/10.1111\/j.1471-0528.2002.01487.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002,10]]},"references-count":21,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2002,10]]}},"alternative-id":["10.1111\/j.1471-0528.2002.01487.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1471-0528.2002.01487.x","archive":["Portico"],"relation":{},"ISSN":["1470-0328","1471-0528"],"issn-type":[{"value":"1470-0328","type":"print"},{"value":"1471-0528","type":"electronic"}],"subject":[],"published":{"date-parts":[[2002,10]]},"assertion":[{"value":"2003-12-22","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}