{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T11:24:28Z","timestamp":1790853868571,"version":"4.1.0"},"reference-count":49,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2006,12,18]],"date-time":"2006-12-18T00:00:00Z","timestamp":1166400000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clin Physio Funct Imaging"],"published-print":{"date-parts":[[2007,1]]},"abstract":"<jats:title>Summary<\/jats:title><jats:p><jats:bold>Background:\u2002<\/jats:bold> There is little understanding of how dental appliances, designed to posture the mandible forwards, act on pharyngeal airway dilatory and masticatory muscles in patients with obstructive sleep apnoea (OSA). This study evaluates, in a prospective cohort design, the effect of mandibular advancement splints (MAS) on awake genioglossus (GG), geniohyoid (GH) and masseter (M) muscle activity.<\/jats:p><jats:p><jats:bold>Methods:\u2002<\/jats:bold> Fifty OSA patients received a custom\u2010made removable Herbst MAS appliance, adjusted for maximum therapeutic benefit, as judged by subjective improvement. Awake electromyographic (EMG) activity was recorded at baseline and with the MAS <jats:italic>in situ<\/jats:italic>, by using bipolar surface electrodes in patients seated upright and in the natural head position. The lower splint was modified to facilitate the placement of the intra\u2010oral bipolar surface electrodes used to record GG EMG activity.<\/jats:p><jats:p><jats:bold>Results:\u2002<\/jats:bold> Significant increases in GG (<jats:italic>P<\/jats:italic>\u2003=\u20030\u00b7041), GH (<jats:italic>P<\/jats:italic>&lt;0\u00b7001) and M (<jats:italic>P<\/jats:italic>&lt;0\u00b7001) muscle activity accompanied placement of the MAS.<\/jats:p><jats:p><jats:bold>Conclusions:\u2002<\/jats:bold> These findings support the contention of a physiological role, which may act to augment the anatomical action of MAS.<\/jats:p>","DOI":"10.1111\/j.1475-097x.2007.00714.x","type":"journal-article","created":{"date-parts":[[2006,12,20]],"date-time":"2006-12-20T10:55:41Z","timestamp":1166612141000},"page":"47-53","source":"Crossref","is-referenced-by-count":66,"title":["The effect of mandibular advancement appliances on awake upper airway and masticatory muscle activity in patients with obstructive sleep apnoea"],"prefix":"10.1111","volume":"27","author":[{"given":"Ama","family":"Johal","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gulsharondip","family":"Gill","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony","family":"Ferman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kieron","family":"McLaughlin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2006,12,18]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0889-5406(05)81003-0"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0889-5406(99)70225-8"},{"key":"e_1_2_7_4_1","first-page":"396","article-title":"Practical statistics for medical research","volume":"404","author":"Altman DG","year":"1995","journal-title":"London Chapman Hall"},{"key":"e_1_2_7_5_1","first-page":"667","article-title":"Sleep\u2010related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research","volume":"22","author":"American Academy of Sleep Medicine Task Force","year":"1995","journal-title":"Sleep"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9343(80)90502-1"},{"key":"e_1_2_7_7_1","first-page":"1477","article-title":"Dental appliances for the treatment of obstructive sleep apnoea","volume":"109","author":"Clark G.T.","year":"1989","journal-title":"J Am Dent Assoc"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/77.6.716"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1985.58.4.1378"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2842.1991.tb00074.x"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm.164.11.2102048"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1113\/jphysiol.2005.083659"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0889-5406(03)00508-0"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.200203-208OC"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0889-5406(97)70293-2"},{"key":"e_1_2_7_16_1","doi-asserted-by":"crossref","first-page":"2508","DOI":"10.1152\/jappl.1991.70.6.2508","article-title":"Respiratory\u2010related recruitment of the masseter: response to hypercapnia and loading","volume":"70","author":"Hollowell DE","year":"1991","journal-title":"J Appl Physiol"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1093\/ortho\/26.3.205"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1038\/sj.bdj.4801025a"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1093\/sleep\/14.6.540"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1093\/ejo\/23.2.127"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1093\/ejo\/24.3.251"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1093\/sleep\/29.2.240"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.rmed.2003.10.009"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1067\/mod.2001.118782"},{"key":"e_1_2_7_25_1","first-page":"172","article-title":"Treatment, airway and compliance effects of a titratable oral appliance","volume":"23","author":"Lowe AA","year":"2000","journal-title":"Sleep"},{"key":"e_1_2_7_26_1","first-page":"443","article-title":"\u2018\u2018Cross\u2010talk\u2019\u2019 in electromyograms: contamination of EMGs recorded with bipolar fine\u2010wire electrodes by volume conducted myoelectric activity from distant sources","volume":"26","author":"Mangun GR","year":"1986","journal-title":"Electromyogr Clin Neurophysiol"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1172\/JCI115751"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm.153.6.8665050"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/0889-5406(88)90033-9"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/0889-5406(88)90357-5"},{"key":"e_1_2_7_31_1","first-page":"51","article-title":"Muscle fibre orientation of abdominal muscles and suggested surface EMG electrode positions","volume":"38","author":"Ng JK","year":"1998","journal-title":"Electromyogr Clin Neurophysiol"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0889-5406(96)70084-7"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1152\/japplphysiol.00978.2004"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1136\/thx.54.11.972"},{"key":"e_1_2_7_35_1","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1152\/jappl.1991.71.2.709","article-title":"Effects of hypoxia and hypercapnia on geniohyoid contractility and endurance","volume":"71","author":"Salmone RJ","year":"1991","journal-title":"J Appl Physiol"},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.99.6.1378"},{"key":"e_1_2_7_37_1","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.200208-866OC"},{"key":"e_1_2_7_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0889-5406(05)81599-9"},{"key":"e_1_2_7_39_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-2002-34313"},{"key":"e_1_2_7_40_1","doi-asserted-by":"publisher","DOI":"10.3109\/00016357109026337"},{"key":"e_1_2_7_41_1","doi-asserted-by":"publisher","DOI":"10.1288\/00005537-199411000-00010"},{"key":"e_1_2_7_42_1","doi-asserted-by":"publisher","DOI":"10.1093\/ortho\/29.4.307"},{"key":"e_1_2_7_43_1","first-page":"117","article-title":"Effects and adverse events of a dental appliance for treatment of obstructive sleep apnoea","volume":"23","author":"Tegelberg A","year":"1999","journal-title":"Swed Dent J"},{"key":"e_1_2_7_44_1","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1007\/BF03045024","article-title":"Mandibular advancement modulates respiratory\u2010related genioglossus electromyographic activity","volume":"4","author":"Tsuiki S","year":"2000","journal-title":"Sleep Breath"},{"key":"e_1_2_7_45_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajodo.2003.05.006"},{"key":"e_1_2_7_46_1","doi-asserted-by":"publisher","DOI":"10.1136\/thx.50.7.797"},{"key":"e_1_2_7_47_1","doi-asserted-by":"publisher","DOI":"10.1136\/thx.54.4.323"},{"key":"e_1_2_7_48_1","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1990.69.4.1262"},{"key":"e_1_2_7_49_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(98)70175-1"},{"key":"e_1_2_7_50_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199304293281704"}],"container-title":["Clinical Physiology and Functional Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1475-097X.2007.00714.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1475-097X.2007.00714.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T23:54:47Z","timestamp":1696982087000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1475-097X.2007.00714.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,12,18]]},"references-count":49,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2007,1]]}},"alternative-id":["10.1111\/j.1475-097X.2007.00714.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1475-097x.2007.00714.x","archive":["Portico"],"relation":{},"ISSN":["1475-0961","1475-097X"],"issn-type":[{"value":"1475-0961","type":"print"},{"value":"1475-097X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,12,18]]}}}