{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T16:34:03Z","timestamp":1788194043090,"version":"build-2803163510"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2005,6,9]],"date-time":"2005-06-09T00:00:00Z","timestamp":1118275200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[2005,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    The purpose of this study was to compare refractions measured with an autorefractor and by retinoscopy with and without cycloplegia. The objective refractions were performed in 199 right eyes from 199 healthy young adults with a mean age of 21.6\u2003\u00b1\u20032.66\u2003years. The measurements were performed first without cycloplegia and repeated 30\u2003min later with cycloplegia. Data were analysed using Fourier decomposition of the power profile. More negative values of component\n                    <jats:italic>M<\/jats:italic>\n                    and\n                    <jats:italic>J<\/jats:italic>\n                    <jats:sub>0<\/jats:sub>\n                    were given by non\u2010cycloplegic autorefraction compared with cycloplegic autorefraction (\n                    <jats:italic>p<\/jats:italic>\n                    \u2003&lt;\u20030.0001). However more positive values for the\n                    <jats:italic>J<\/jats:italic>\n                    <jats:sub>45<\/jats:sub>\n                    vector were given by non\u2010cycloplegic autorefraction, although this difference was not statistically significant (\n                    <jats:italic>p<\/jats:italic>\n                    \u2003=\u20030.233). By retinoscopy, more negative values of component\n                    <jats:italic>M<\/jats:italic>\n                    were obtained with non\u2010cycloplegic retinoscopy (\n                    <jats:italic>p<\/jats:italic>\n                    \u2003&lt;\u20030.0001); for the cylindrical vectors\n                    <jats:italic>J<\/jats:italic>\n                    <jats:sub>0<\/jats:sub>\n                    and\n                    <jats:italic>J<\/jats:italic>\n                    <jats:sub>45<\/jats:sub>\n                    the retinoscopy without cycloplegia yields more negative values (\n                    <jats:italic>p<\/jats:italic>\n                    \u2003=\u20030.234;\n                    <jats:italic>p<\/jats:italic>\n                    \u2003=\u20030.112, respectively). Accepting that differences between cycloplegic and non\u2010cycloplegic retinoscopy are only due to the accommodative response, the present results confirm that when performed by an experienced clinician, retinoscopy is a more reliable method to obtain the objective starting point for refraction under non\u2010cycloplegic conditions.\n                  <\/jats:p>","DOI":"10.1111\/j.1475-1313.2005.00277.x","type":"journal-article","created":{"date-parts":[[2005,6,9]],"date-time":"2005-06-09T05:04:12Z","timestamp":1118293452000},"page":"340-345","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":49,"title":["The influence of cycloplegia in objective refraction"],"prefix":"10.1007","volume":"25","author":[{"given":"J.","family":"Jorge","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Queiros","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Gonz\u00e1lez\u2010M\u00e9ijome","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Fernandes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. B.","family":"Almeida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. A.","family":"Parafita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2005,6,9]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200303000-00014"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(95)91748-9"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199808000-00028"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199405000-00002"},{"key":"e_1_2_5_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0953-4431(98)00024-1"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.83.2.157"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1076\/stra.9.2.59.701"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200304000-00011"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.70.3.221"},{"key":"e_1_2_5_12_1","first-page":"619","article-title":"Reliability of refraction \u2013 a literature review","volume":"67","author":"Goss D. A.","year":"1996","journal-title":"J. Am. Optom. Assoc."},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199905000-00016"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200401000-00011"},{"key":"e_1_2_5_15_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.02-0816"},{"key":"e_1_2_5_16_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200111000-00014"},{"key":"e_1_2_5_17_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.81.11.941"},{"key":"e_1_2_5_18_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.1999.00412.x"},{"key":"e_1_2_5_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0197-2456(01)00156-8"},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(00)00861-8"},{"key":"e_1_2_5_21_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.80.1.35"},{"key":"e_1_2_5_22_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.2001.00585.x"},{"key":"e_1_2_5_23_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-198511000-00011"},{"key":"e_1_2_5_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.1993.tb00441.x"},{"key":"e_1_2_5_25_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.71.1.73"},{"key":"e_1_2_5_26_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.71.9.682"},{"key":"e_1_2_5_27_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199508000-00007"},{"key":"e_1_2_5_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00033-4"},{"key":"e_1_2_5_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(00)04522-0"},{"key":"e_1_2_5_30_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.1998.tb06729.x"},{"key":"e_1_2_5_31_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199706000-00019"},{"key":"e_1_2_5_32_1","first-page":"23","article-title":"Repeatability and validity of astigmatism measurements","volume":"15","author":"Walline J. J.","year":"1999","journal-title":"J. Refract. Surg."},{"key":"e_1_2_5_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(98)00070-1"},{"key":"e_1_2_5_34_1","first-page":"2325","article-title":"The repeatability of measurement of the ocular components","volume":"33","author":"Zadnik K.","year":"1992","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"e_1_2_5_35_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199408000-00008"}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1475-1313.2005.00277.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1475-1313.2005.00277.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:24:11Z","timestamp":1767785051000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1475-1313.2005.00277.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,6,9]]},"references-count":34,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2005,7]]}},"alternative-id":["10.1111\/j.1475-1313.2005.00277.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1475-1313.2005.00277.x","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,6,9]]},"assertion":[{"value":"2005-06-09","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}