{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,17]],"date-time":"2026-03-17T15:57:51Z","timestamp":1773763071035,"version":"3.50.1"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2008,6,28]],"date-time":"2008-06-28T00:00:00Z","timestamp":1214611200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[2008,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:bold>Aim:\u2002<\/jats:bold>\n                    To compare intraocular pressure (IOP) values obtained with the iCare rebound tonometer (RBT) with values obtained with the Goldmann applanation tonometer (GAT) in patients with glaucoma and ocular hypertension, and to evaluate the impact of possible differences on management decisions.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Methods:\u2002<\/jats:bold>\n                    The IOP was measured with the iCare RBT and GAT in 45 consecutive patients in a nurse\u2010led glaucoma unit. The outcome measures were the IOP difference between the methods and the 95% limits of agreement (LoA) for IOP measurements. In all subjects where the IOP readings differed by &gt;3\u2003mmHg between the RBT and GAT, two ophthalmologists were independently asked to recommend treatment and\/or follow\u2010up intervals, based on the patients\u2019 clinical data and the IOP values.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Results:\u2002<\/jats:bold>\n                    The RBT overestimated the IOP compared with GAT in 67% of the cases (30\/45). In 78% (35\/45) the IOP difference was within \u00b13\u2003mmHg. When an extreme value of 15\u2003mmHg difference was excluded, the 95% LoA was \u00b14.31\u2003mmHg. In five of the 10 patients with an IOP difference of\u2003&gt;\u2003\u00b1\u20033\u2003mmHg the difference would have led to change in therapy; in three more patients the follow\u2010up interval would have been changed. In the remaining two patients the difference in IOP would not have led to any change in management.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Conclusions:\u2002<\/jats:bold>\n                    The mean difference between RBT and GAT was small (1.5\u2003\u00b1\u20033\u2003mmHg) compared with the published repeatability of GAT values. Yet, the difference was found to have clinical implications in 18% (8\/45) of the patients.\n                  <\/jats:p>","DOI":"10.1111\/j.1475-1313.2008.00571.x","type":"journal-article","created":{"date-parts":[[2008,6,17]],"date-time":"2008-06-17T09:20:53Z","timestamp":1213694453000},"page":"382-386","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":32,"title":["Comparison of rebound and applanation tonometry in the management of patients treated for glaucoma or ocular hypertension"],"prefix":"10.1007","volume":"28","author":[{"given":"Jeannette B.","family":"Rehnman","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lene","family":"Martin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2008,6,28]]},"reference":[{"key":"e_1_2_6_2_1","article-title":"Comparison of the iCare\u00ae rebound tonometer with the Goldmann applanation tonometer by experienced and inexperienced tonometrists","author":"Abraham L. M.","year":"2006","journal-title":"Eye"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199510000-00008"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(95)91748-9"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(01)00760-6"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.ijg.0000212208.87523.66"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.2005.00610.x"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0181-5512(06)73907-9"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF00176782"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.85.1.85"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2005.00327.x"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.opx.0000200673.96758.7b"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.120.6.714"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2005.00318.x"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02569066"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.121.1.48"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/00055735-200404000-00008"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.2003.tb03068.x"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0420.1999.770123.x"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.05-0586"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.02.035"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF00411443"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-199612000-00009"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-006-0483-3"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2007.01451.x"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0b013e31802fc6bc"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-200506000-00009"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00347-007-1487-z"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.1993.tb04988.x"}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1475-1313.2008.00571.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1475-1313.2008.00571.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:25:17Z","timestamp":1767785117000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1475-1313.2008.00571.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,6,28]]},"references-count":29,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2008,7]]}},"alternative-id":["10.1111\/j.1475-1313.2008.00571.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1475-1313.2008.00571.x","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,6,28]]},"assertion":[{"value":"2008-06-28","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}