{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T11:48:30Z","timestamp":1793533710674,"version":"4.5.0"},"reference-count":48,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2008,8,18]],"date-time":"2008-08-18T00:00:00Z","timestamp":1219017600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[2008,9]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    <jats:bold>Purpose:\u2002<\/jats:bold>\n                    To utilize time\u2010domain optical coherence tomography (OCT) to measure changes in the crystalline lens with age and accommodation.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Methods:\u2002<\/jats:bold>\n                    A cross\u2010sectional study of pre\u2010presbyopic and presbyopic subjects was conducted. Amplitude of accommodation was measured with the push\u2010up test. Objective accommodation was measured with the Grand Seiko auto\u2010refractor and a Badal lens system. Lens thickness was measured with the Zeiss Visante OCT and an internal optometer. The data were analysed using correlation coefficients, linear regression, and by calculating the average change in lens thickness per diopter change in objective accommodation.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Results:\u2002<\/jats:bold>\n                    Twenty\u2010two subjects between the ages of 36 and 50\u2003years completed the study. Subjective amplitude of accommodation ranged from 2.17 to 6.38\u2003D. Objective accommodation ranged from 0.22 to 4.56\u2003D. The mean lens thickness was 4.05\u2003\u00b1\u20030.20\u2003mm. The mean change in lens thickness for up to a 5\u2010D accommodative stimulus ranged from 0.01 to 0.26\u2003mm. The correlation coefficients were: age and subjective accommodation,\n                    <jats:italic>r<\/jats:italic>\n                    \u2003=\u2003\u22120.74; age and objective accommodation,\n                    <jats:italic>r<\/jats:italic>\n                    \u2003=\u2003\u22120.84; change in lens thickness and age,\n                    <jats:italic>r<\/jats:italic>\n                    \u2003=\u2003\u22120.65; change in lens thickness and subjective accommodation,\n                    <jats:italic>r<\/jats:italic>\n                    \u2003=\u20030.74; change in lens thickness and objective accommodation,\n                    <jats:italic>r<\/jats:italic>\n                    \u2003=\u20030.64; objective and subjective accommodation,\n                    <jats:italic>r<\/jats:italic>\n                    \u2003=\u20030.82 (all\n                    <jats:italic>p<\/jats:italic>\n                    \u2003&lt;\u20030.01). An increase in lens thickness of 21\u2003\u03bcm per year of age was determined by linear regression. For the subjects who showed at least 1\u2003D of accommodative response on the Grand Seiko auto\u2010refractor, there was an increase of 51\u2003\u00b1\u200319\u2003\u03bcm per dioptre of accommodation.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Conclusions:\u2002<\/jats:bold>\n                    Optical coherence tomography is a non\u2010invasive technique that can be used to quantify changes in the thickness of the crystalline lens. Subjective and objective measurements of accommodation, as well as age, were robustly correlated with the measured changes in lens thickness. Lens thickness changes with age and accommodation as measured with the Visante OCT compare well with previous findings using Scheimpflug photography and ultrasound.\n                  <\/jats:p>","DOI":"10.1111\/j.1475-1313.2008.00594.x","type":"journal-article","created":{"date-parts":[[2008,8,18]],"date-time":"2008-08-18T10:32:28Z","timestamp":1219055548000},"page":"441-447","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":93,"title":["Lens thickness with age and accommodation by optical coherence tomography"],"prefix":"10.1007","volume":"28","author":[{"given":"Kathryn","family":"Richdale","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark A.","family":"Bullimore","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karla","family":"Zadnik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2008,8,18]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.1995.9500020e.x"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199405000-00006"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.05.024"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2003.12.043"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(94)90058-2"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199404000-00004"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2006.099879"},{"key":"e_1_2_6_9_1","article-title":"Factors affecting the accommodative response in an adult myopic population","volume":"84","author":"Bullimore M.","year":"2007","journal-title":"Optom. Vis. Sci."},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(97)00066-7"},{"key":"e_1_2_6_11_1","first-page":"1304","article-title":"Submicrometer precision biometry of the anterior segment of the human eye","volume":"38","author":"Drexler W.","year":"1997","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(01)00057-8"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-200106000-00013"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(03)00428-0"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2004.07.032"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1117\/1.2821844"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01652-8"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0301-5629(96)00213-X"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.1997.9600049x.x"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199702000-00024"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.1997.96000506.x"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(13)80737-7"},{"key":"e_1_2_6_23_1","first-page":"1","article-title":"Accommodation: mechanism and measurement","volume":"19","author":"Glasser A.","year":"2006","journal-title":"Ophthalmol. Clin. North Am."},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(97)00102-8"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(98)00283-1"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.04.026"},{"key":"e_1_2_6_27_1","first-page":"703","article-title":"Change with age of the refractive index gradient of the human ocular lens","volume":"36","author":"Hemenger R. P.","year":"1995","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e318157c6b5"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.2003.00168.x"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.exer.2004.12.004"},{"key":"e_1_2_6_31_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2006.103408"},{"key":"e_1_2_6_32_1","doi-asserted-by":"publisher","DOI":"10.1038\/scientificamerican0788-92"},{"key":"e_1_2_6_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(89)90150-8"},{"key":"e_1_2_6_34_1","first-page":"569","article-title":"Accommodation and presbyopia in the human eye. Changes in the anterior segment and crystalline lens with focus","volume":"38","author":"Koretz J. F.","year":"1997","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"e_1_2_6_35_1","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.21.000346"},{"key":"e_1_2_6_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2004.09.021"},{"key":"e_1_2_6_37_1","article-title":"Vaildation of the visante anerior segment OCT in measurements of crystalline lens thickness","volume":"84","author":"Lehman B.","year":"2007","journal-title":"Optom. Vis. Sci."},{"key":"e_1_2_6_38_1","first-page":"120","article-title":"Optical and structural development of the crystalline lens in childhood","volume":"39","author":"Mutti D. O.","year":"1998","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"e_1_2_6_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0014-4835(05)80114-9"},{"key":"e_1_2_6_40_1","doi-asserted-by":"publisher","DOI":"10.1016\/0167-4943(94)00617-G"},{"key":"e_1_2_6_41_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.1996.95000933.x"},{"key":"e_1_2_6_42_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.2003.tb03053.x"},{"key":"e_1_2_6_43_1","first-page":"1162","article-title":"Age\u2010related changes in human ciliary muscle and lens: a magnetic resonance imaging study","volume":"40","author":"Strenk S. A.","year":"1999","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"e_1_2_6_44_1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.03-0092"},{"key":"e_1_2_6_45_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.05.021"},{"key":"e_1_2_6_46_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1440-1606.1999.00162.x"},{"key":"e_1_2_6_47_1","doi-asserted-by":"publisher","DOI":"10.1016\/0014-4835(83)90110-0"},{"key":"e_1_2_6_48_1","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3181559ace"},{"key":"e_1_2_6_49_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00667-9"}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1475-1313.2008.00594.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1475-1313.2008.00594.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:25:18Z","timestamp":1767785118000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1475-1313.2008.00594.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,8,18]]},"references-count":48,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2008,9]]}},"alternative-id":["10.1111\/j.1475-1313.2008.00594.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1475-1313.2008.00594.x","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,8,18]]},"assertion":[{"value":"2008-08-18","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}